Catalog excerpts
Non-contacting speed sensor type FA54 with aluminium flange and stainless steel sensor tube NOR/S Scanning type Application range Speed sensors type series FA54 are compact and robust flange sensors with type approval from all common ship class societies. They are suitable for scanning ferromagnetic objects, such as toothed wheels, bolt heads, drillings/boreholes, gaps, grooves or impulse bands. The different sensor variants allow measurements with up to two measuring channels and up to four output signals for measurement of frequencies from 0 to 20 kHz. Thus, they are suitable for standstill detection and for rotational direction detection by using phase shifted signals. Different sensor tube lengths and connection outlets as well as your tailor-made solution on request enable an adaptation to almost any application. Do not hesitate to contact our technical sales team (sales@noris-group.com) and ask for a quotation. Special features • Robust and high quality housing: IP68 pressure-tight • Excellent vibration and shock resistance • High degree of EMC immunity for difficult electrical environment • Connection outlet straight or lateral; with protective tubing on request • Up to four output signals, on request available with one status signal for rotational direction detection, on request with two galvanically isolated output signals • Due to its design and its approvals especially suitable for shipbuilding industry Measuring principle Hall principle A field of a magnet generates a constant voltage in the Hall elements. Ferromagnetic objects with an interrupted surface cause the Hall voltage to change as they pass the Hall elements. The frequency of the change of the Hall voltage is proportional to the speed of movement (rotational speed). The speed sensor converts this change into an electric signal. Datasheet DB-FA54-EN | V01.00 | 09/10/2019 | Valid from product revision A | www.noris-group.com | sales@noris-group.com
Open the catalog to page 1| Overview speed sensors FA[..]54 NORIS Automation GmbH Overview speed sensors FA[..]54 Type Measuring principle Signal outputs One square wave signal Two square wave signals, Q2 to Q1 is 90° phase shifted Signal form Two square wave signals, Q2 to Q1 is 90° phase shifted, one rotation direction signal Two galvanically isolated square wave signals, Q2 to Q1 is 90° phase shifted Two + Two inverted square wave signals, Q1 to Q2 and Q1_N to Q2_N are 90° phase shifted Two square wave signals, Q1_N inverted to Q1 NORIS Automation GmbH | Muggenhofer Str. 95 | 90429 Nuremberg | Germany | Tel: +49...
Open the catalog to page 2NORIS Automation GmbH Dimensions, connections and drawings | Dimensions, connections and drawings Dimensions and mounting drawing Explanation to the left illustration C Fig.: Borehole for FA[..]54_Top view Recommended fixing: Hexagon socket screw DIN912 M6x20 with spring washer. Explanation to the left illustration A) Flange: Aluminium B) O-ring 17.17 x 1.78 mm C) Sensor tube: Stainless steel D) Length 34 mm L1) Nominal length L1 (see type code) E) Length 10 mm F) Length 5 mm G) Ø 16 mm H) Bend protection Explanation to the left illustration A) Flange: Aluminium B) O-ring 17.17 x 1.78 mm C)...
Open the catalog to page 3| Dimensions, connections and drawings NORIS Automation GmbH A) Sensor housing (flange) D) Recommended distance from scanning object see technical data C) Length K1 ± 5% (K1 see customer drawing) DB-FA54-EN NORIS Automation GmbH | Muggenhofer Str. 95 | 90429 Nuremberg | Germany | Tel: +49 911 3201-220 | Fax: +49 911 3201-150 | sales@noris-group.com | www.noris-group.com Errors and omissions excepted
Open the catalog to page 4NORIS Automation GmbH Dimensions, connections and drawings | Explanation to the left illustration A) Wires 6 x 0.33 mm2 halogen-free C) Length K1 ± 5% (K1 see customer drawing) Connection assignment for type FA[..] with one output signal DB-FA54-EN NORIS Automation GmbH | Muggenhofer Str. 95 | 90429 Nuremberg | Germany | Tel: +49 911 3201-220 | Fax: +49 911 3201-150 | sales@noris-group.com | www.noris-group.com Errors and omissions excepted
Open the catalog to page 5| Dimensions, connections and drawings NORIS Automation GmbH Connection assignment for type FA[..]D DB-FA54-EN NORIS Automation GmbH | Muggenhofer Str. 95 | 90429 Nuremberg | Germany | Tel: +49 911 3201-220 | Fax: +49 911 3201-150 | sales@noris-group.com | www.noris-group.com Errors and omissions excepted
Open the catalog to page 6NORIS Automation GmbH Dimensions, connections and drawings | Elementary circuit diagram FAH54, FAHZ54 NORIS Automation GmbH Dimensions, connections and drawings | Elementary circuit diagram FAHS54 Ub+ Elementary circuit diagram FAHD54 Elementary circuit diagram FAHQ54, FAHY54 oUb- (0V) DB-FA54-EN NORIS Automation GmbH | Muggenhofer Str. 95 | 90429 Nuremberg | Germany | Tel: +49 911 3201-220 | Fax: +49 911 3201-150 | sales@noris-group.com | www.noris-group.com Errors and omissions excepted
Open the catalog to page 7| General technical data NORIS Automation GmbH DB-FA54-EN NORIS Automation GmbH | Muggenhofer Str. 95 | 90429 Nuremberg | Germany | Tel: +49 911 3201-220 | Fax: +49 911 3201-150 | sales@noris-group.com | www.noris-group.com Errors and omissions excepted
Open the catalog to page 8NORIS Automation GmbH General technical data | DB-FA54-EN NORIS Automation GmbH | Muggenhofer Str. 95 | 90429 Nuremberg | Germany | Tel: +49 911 3201-220 | Fax: +49 911 3201-150 | sales@noris-group.com | www.noris-group.com Errors and omissions excepted
Open the catalog to page 9| Specific technical data NORIS Automation GmbH Sensors with one output signal DB-FA54-EN NORIS Automation GmbH | Muggenhofer Str. 95 | 90429 Nuremberg | Germany | Tel: +49 911 3201-220 | Fax: +49 911 3201-150 | sales@noris-group.com | www.noris-group.com Errors and omissions excepted
Open the catalog to page 10NORIS Automation GmbH Type code | NORIS Automation GmbH Type code | Special types If our standard types do not correspond with your expectations, we are pleased to develop a special solution together with you. DB-FA54-EN NORIS Automation GmbH | Muggenhofer Str. 95 | 90429 Nuremberg | Germany | Tel: +49 911 3201-220 | Fax: +49 911 3201-150 | sales@noris-group.com | www.noris-group.com Errors and omissions excepted
Open the catalog to page 11All NORIS Group GmbH catalogs and technical brochures
-
Datasheet EOT
6 Pages
-
NORIS yacht brochure
16 Pages
-
Flyer myNORIS
3 Pages
-
Energy Storage System
2 Pages
-
NORIS Marine Overview
13 Pages
-
Flyer NORIMOS 4
3 Pages
-
Flyer N3500
3 Pages
-
Datasheet NORISPEED FMN6
2 Pages
-
Datasheet TAV131
6 Pages
-
Datasheet TA14
5 Pages
-
Datasheet TA17
5 Pages
-
Datasheet VFS5
2 Pages
-
Datasheet RTK5
2 Pages
-
Datasheet RI5
2 Pages
-
Datasheet RFJ5
2 Pages
-
Datasheet PAx9
6 Pages
-
Datasheet FA11
14 Pages
-
Datasheet VF5..-KD
2 Pages
-
Datenblatt VFS5
2 Pages
-
Datasheet VFW5
2 Pages
-
Datasheet NIR3 NIQ3
20 Pages
-
Flyer NORISYS 4 CPU
2 Pages
-
Datasheet RG5
2 Pages
-
Datasheet SIR3 SIQ3
10 Pages
-
Datasheet RFG5
2 Pages
-
Datasheet FA13
14 Pages
-
Datasheet NIQ3
20 Pages
-
Datasheet FAH52
14 Pages
-
Datasheet FAHZ53
7 Pages
-
Datasheet VP5
2 Pages
-
Datasheet RFW5
2 Pages
-
Datasheet RH41M
2 Pages
-
Datasheet RH5
2 Pages
-
Datasheet RF5
2 Pages
-
Datasheet RP5, RPT5
2 Pages
-
NORIYSY 4 Deep Sea
2 Pages
-
Flyer N3000-SAP
1 Pages
-
Datasheet
2 Pages
-
Datasheet DWA
4 Pages
-
Datasheet TA18
5 Pages
-
Flyer NORISYS 4 PMC
2 Pages
-
Datasheet VTK5
2 Pages
-
Datasheet GE1214
2 Pages
-
Datasheet GE12
2 Pages
-
Datasheet GZ121
2 Pages
-
Datasheet VPT5
2 Pages
-
Datasheet GE14
2 Pages
-
Datasheet NADS3
2 Pages
-
Datasheet NIQ31
16 Pages
-
Datasheet NAD1
2 Pages
-
Datasheet NAD2
2 Pages
-
NORIS Group GmbH Brochure en
13 Pages
-
NORIS Brochure
15 Pages
-
Datasheet TP31 TH31
5 Pages
-
Datasheet TP23
4 Pages
-
Datasheet VD61
6 Pages
-
Datasheet VF5
2 Pages
-
RW5
2 Pages
Archived catalogs
-
Speed sensor Type FAW
1 Pages
-
stepper motor principle
1 Pages
-
Combi-sensor Type KA
1 Pages
-
moving-coil element
1 Pages
-
Combi-sensor Type KA
1 Pages