High pressure Sight Glass Indicator NORIS Bauform 912 Application: The flow indicators are used for optical control of fluids and gases, for horizontal and vertical pipe lines. Operating conditions: Working pressure: Working temperature: up to 160 bar with borosilicate glass max. 280° C with quarzglass up to 500° C High pressure design Installation: Optional Possible Connection: Flange connection acc. to DIN up to PN 160 Flange connection acc. to ANSI up to 1.500 LBS Butt weld ends Female-threaded Dimensions: Working pressure and nominal diameter have an affect on the length. Options: with - ANSI-flanges - Butt weld ends - Heating jacket - Sight glass light - fittings Materials: All materials which can be welded are possible. Certificate: ( Option ) Acc. to EN 10204 - 2.2 or Acc. to EN 10204-3.1 E912 09/07 Modification reserved NORIS ARMATUREN Burkenstein GmbH & Co. KG Puscherstrasse 3 D-90411 Nürnberg Telefon: +49 (0) 911 / 52 150 63 Telefax: +49 (0) 911 / 52 24 40 Internet: Noris-Armaturen.de E-Mail: [email protected]