{{requestButtons}}

Catalog excerpts

Elastomer Nozzle - 2

NAFTA Xaloy Inc. 72 Stard Road, Seabrook, NH 03874, USA Tel: +1 603 929 8246 Toll free: +1 866 533 1092 Fax: +1 603 929 8332 Japan 2 Version 00 Xaloy Inc. 74-1 Yamashita-cho, Naka-Ku - Yokohama, 231-0023 Tel: +81-45-661-3508 Fax: +81-45-661-3507 Asia Xaloy Asia (Thailand) Ltd. 700/446 Moo 7, Donhuaroh| Muang Chonburi, Chonburi 20000, Thailand Tel: +66 38 717 084 Fax: +66 38 454 377 >

Open the catalog to page 2
Elastomer Nozzle - 3

NAFTA Xaloy Inc. 72 Stard Road, Seabrook, NH 03874, USA Tel: +1 603 929 8246 Toll free: +1 866 533 1092 Fax: +1 603 929 8332 Japan 3 Version 00 Xaloy Inc. 74-1 Yamashita-cho, Naka-Ku - Yokohama, 231-0023 Tel: +81-45-661-3508 Fax: +81-45-661-3507 Asia Xaloy Asia (Thailand) Ltd. 700/446 Moo 7, Donhuaroh| Muang Chonburi, Chonburi 20000, Thailand Tel: +66 38 717 084 Fax: +66 38 454 377 >

Open the catalog to page 3
Elastomer Nozzle - 4

3. Data sheet Technical data E0 E1 max. injection rate cm > 3 / s 350 1500 max. nozzle contact force in kN 70 120 smallest / largest nozzle orifice (mm) M by max. injection rate 3 / ؘ 5 3 / ؘ 8 ( 10) max. back pressure 600 bar (at actuator 10 bar) 1800 bar (at actuator 10 bar) max. injection pressure 2500bar 2500bar temperature range -20ذC / 180C -20аC / 180C flow channel 30mm > 2 150mm > 2 Cold runner tip Direct gate Actuator E0 E1 pneumatic 4 - 10 bar 4 - 10 bar operation mode 2 - way 2 - way Connection pneumatic tempering system 2 x G1/8 2 x G1/8 2 x G1/8 2 x G1/4 Standard measurements...

Open the catalog to page 4
Elastomer Nozzle - 6

5. Installation Instructions Mounting A) Follow the instructions according to the graphics on the left. The nozzle arrives preassembled. Please inspect and grease the adapter before installation. Refer also to the machine handbook before installation. Tip / needle removal, see page 7 Max. working conditions: 2500bar at 110C manually grease with silicon paste / teflon tape match temperatures inspect Legend > 1. Inspect the threads and surfaces 2. Grease adapter thread with silicon paste or encapsulate with teflon band 3. Insert and hand-tighten the adapter Tools required: E0 Part Tool E0 B)...

Open the catalog to page 6
Elastomer Nozzle - 7

Servicing: Inspect and clean all parts. Check all parts regarding scouring, tolerances or damage. Replace when necessary only with genuine Herzog manufactured parts. Parts may vary according to individual customer specifications. We offer our customers a cleaning service. The nozzle will be disassembled, inspected and a rec- ommendation would be given for the parts which are in need of replacement. Code Tip Removal (reverse order for installation - refer also to table on page 6 for torques) Needle Removal (reverse order for installation - refer also to table on page 6 for torques) 1. 2. 3....