CapScan

CapScan

CapScan

Product catalog summary
Introduction
The document discusses the Beta LaserMike CapScan 2000, a capacitance measurement solution designed for cable manufacturers to ensure consistency between in-process and post-process measurements. This is crucial for meeting challenging specifications in datacom cables, such as Structural Return Loss, Near- and Far-end Cross Talk, and Attenuation.

Key Features
The CapScan 2000 offers several advantages:
  • Minimal external interference due to complete EMC shielding.
  • Enhanced accuracy with a self-balancing bridge, automatic gain, and self-calibration.
  • Superior repeatability through a Digital Signal Processor (DSP) with complex filtering algorithms.
  • Accurate readings in both wet and dry installations at line speeds up to 3000 m/min.
  • Environmental protection with IP68 and IP65 designs.

Gauge Head Models
The CapScan 2000 is available in different models for various applications:
  • KG2008: Standard gauge for most applications.
  • KG2016 and KG2025: For larger diameter cables, up to 25 mm.

Special Applications
The system includes options for:
  • On-line SRL Analysis using FFT algorithms for real-time analysis.
  • Dry trough installations with high-pressure end caps.

Connectivity and Data Access
The CapScan 2000 can connect to the KI1000 indicator unit via CANBUS for reliable data indication. It supports various communication interfaces, including Profibus, DeviceNet, and RS-232.

Specifications
The document provides detailed specifications for the gauge heads and the KI1000 indicator, including:
  • Cable range, accuracy, and SRL bandwidth for each model.
  • Power supply and temperature range requirements.
  • Dimensions and weight of the KI1000 indicator.

Conclusion
The Beta LaserMike CapScan 2000 is a comprehensive solution for cable manufacturers, offering high accuracy, repeatability, and flexibility in capacitance measurement, with robust connectivity options for integration into existing systems.
See more

Catalog excerpts

CapScan-1

Drift-Free, In-Process BETA LaserMike CapScan 2000 Capacitance Measurement Solution The CapScan 2000 system delivers the following advantages: Unrivalled technology for greater consistency between in-process and post-process capacitance measurements. Minimal external interference due to the complete EMC shielding of an all-in-one, stainless-steel design As datacom cable manufacturers face more challenging specifications for Structural Return Loss, Near- and Far-end Cross Talk and Attenuation, it’s more important than ever to catch problems as they develop – not after the fact. Because downgrading or rejecting finished cable robs you of productivity and profitability. Enhanced accuracy due to a unique self-balancing bridge, automatic gain, and automatic self calibration Superior repeatability due to a Digital Signal Processor (DSP) running complex filtering algorithms Accurate readings on wet or dry trough installations with line speeds up to 3000 m/min (10,000 ft/min) IP68 (NEMA 6P) head and IP65 (NEMA 4) design prevents degradation of readings due to environmental factors including changes in water resistance from chemical impurities That’s why correlating in-process and post-process measurement results accurately and consistently is so important. And precisely why the Beta LaserMike CapScan 2000 is the capacitance measurement solution of choice for cable manufacturers worldwide. Unique, drift-free operation provides superior repeatability The CapScan 2000 gauging system provides on-line, high-speed measurement of cable capacitance. A combination of low signal-to-noise ratio and proprietary, drift-free electronics enable the system to deliver highly accurate and consistent measurements. With a local intelligence module directly connected to the measurement head, the CapScan 2000 system can communicate directly to the Beta LaserMike DataPro controllers or other host systems.

 Open the catalog to page 1
CapScan-2

BETA LaserMike A range of gauge heads and simple, reliable data indication for a broad scope of applications Range of gauge heads The KG2008 model is the standard gauge for most applications. It may be mounted at any location in the trough. Special versions are available for installation in multi-pass through applications. The KG2016 and KG2025 models are designed for use on larger diameter cables, up to 25 mm (1 in.), for applications including special CATV, coax, cell phone, and TV antennae extrusions. Flexible connectivity For maximum flexibility, CapScan 2000 models are available in Profibus,...

 Open the catalog to page 2
CapScan-3

BETA LaserMike General Gauge Specifications Cable Range Short Electrode Length Long Electrode Length Gauge Head Dimensions Length: 447 mm (17.6 in.) with CAPS; 368 mm (14.49 in.) without CAPS Diameter: 50.8 mm (2.0 in.) Length: 629.8 mm (24.8 in.) with CAPS; 573 mm (22.56 in.) without CAPS Diameter: 70 mm (2.76 in.) Length: 727.6 mm (28.65 in.) with CAPS; 670.7 mm (26.4 in.) without CAPS Diameter: 76 mm (3.0 in.) Measurement Range 0.1 pF/m (0.01 pF/m option for averaging over 0.5 sec.) 0.03 pF/ft (0.003 pF/ft. with averaging over 0.5 sec.) Power Supply 11 to 25 VDC ( DeviceNet standard ), 6 W...

 Open the catalog to page 3
CapScan-4

KI1000 Indicator Specifications Functionality RS-232 output Programmable analog outputs (three available) Diagnostic contact Digital display and keypad Contact outputs Line speed input Line start/stop input ASCII printer output Statistics data Power Requirements Operating Temperature Dimensions (LxHxW) Indicator Body (LxHxW): 243.8 x 142.2 x 111.8 mm (9.6 x 5.6 x 4.4 in.)* Front Mounting Plate (WxH): 152.4 x 129.5 mm (6 x 5.1 in.)** 1.5 kg (3.3 lb.) *Allow ample room for cabling. **Refer to product manual for mounting hole dimensions. Additional information on key features and options Digital...

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.