CapScan
4Pages

{{requestButtons}}

Catalog excerpts

CapScan - 1

Drift-Free, In-Process BETA LaserMike CapScan 2000 Capacitance Measurement Solution The CapScan 2000 system delivers the following advantages: Unrivalled technology for greater consistency between in-process and post-process capacitance measurements. Minimal external interference due to the complete EMC shielding of an all-in-one, stainless-steel design As datacom cable manufacturers face more challenging specifications for Structural Return Loss, Near- and Far-end Cross Talk and Attenuation, it’s more important than ever to catch problems as they develop – not after the fact. Because downgrading or rejecting finished cable robs you of productivity and profitability. Enhanced accuracy due to a unique self-balancing bridge, automatic gain, and automatic self calibration Superior repeatability due to a Digital Signal Processor (DSP) running complex filtering algorithms Accurate readings on wet or dry trough installations with line speeds up to 3000 m/min (10,000 ft/min) IP68 (NEMA 6P) head and IP65 (NEMA 4) design prevents degradation of readings due to environmental factors including changes in water resistance from chemical impurities That’s why correlating in-process and post-process measurement results accurately and consistently is so important. And precisely why the Beta LaserMike CapScan 2000 is the capacitance measurement solution of choice for cable manufacturers worldwide. Unique, drift-free operation provides superior repeatability The CapScan 2000 gauging system provides on-line, high-speed measurement of cable capacitance. A combination of low signal-to-noise ratio and proprietary, drift-free electronics enable the system to deliver highly accurate and consistent measurements. With a local intelligence module directly connected to the measurement head, the CapScan 2000 system can communicate directly to the Beta LaserMike DataPro controllers or other host systems.

Open the catalog to page 1
CapScan - 2

BETA LaserMike A range of gauge heads and simple, reliable data indication for a broad scope of applications Range of gauge heads The KG2008 model is the standard gauge for most applications. It may be mounted at any location in the trough. Special versions are available for installation in multi-pass through applications. The KG2016 and KG2025 models are designed for use on larger diameter cables, up to 25 mm (1 in.), for applications including special CATV, coax, cell phone, and TV antennae extrusions. Flexible connectivity For maximum flexibility, CapScan 2000 models are available in...

Open the catalog to page 2
CapScan - 3

BETA LaserMike General Gauge Specifications Cable Range Short Electrode Length Long Electrode Length Gauge Head Dimensions Length: 447 mm (17.6 in.) with CAPS; 368 mm (14.49 in.) without CAPS Diameter: 50.8 mm (2.0 in.) Length: 629.8 mm (24.8 in.) with CAPS; 573 mm (22.56 in.) without CAPS Diameter: 70 mm (2.76 in.) Length: 727.6 mm (28.65 in.) with CAPS; 670.7 mm (26.4 in.) without CAPS Diameter: 76 mm (3.0 in.) Measurement Range 0.1 pF/m (0.01 pF/m option for averaging over 0.5 sec.) 0.03 pF/ft (0.003 pF/ft. with averaging over 0.5 sec.) Power Supply 11 to 25 VDC ( DeviceNet standard ), 6...

Open the catalog to page 3
CapScan - 4

KI1000 Indicator Specifications Functionality RS-232 output Programmable analog outputs (three available) Diagnostic contact Digital display and keypad Contact outputs Line speed input Line start/stop input ASCII printer output Statistics data Power Requirements Operating Temperature Dimensions (LxHxW) Indicator Body (LxHxW): 243.8 x 142.2 x 111.8 mm (9.6 x 5.6 x 4.4 in.)* Front Mounting Plate (WxH): 152.4 x 129.5 mm (6 x 5.1 in.)** 1.5 kg (3.3 lb.) *Allow ample room for cabling. **Refer to product manual for mounting hole dimensions. Additional information on key features and options...

Open the catalog to page 4