Overview: The Tank Mount pH Control System is designed for accurate pH measurement directly in ink pails using a flat tip pH probe. This system ensures reliable pH monitoring and control in industrial settings.
Specifications: The sensor assembly can be mounted on the ink pail cover or a Norcross viscosity measuring element. It connects to a transmitter via a plastic pipe with internal wiring, converting the pH probe signal into a 4-20 mA DC signal for the MP2000pH controller.
Operation: Operators set a desired pH value in the controller, which compares it with the actual pH. If the pH falls below the setpoint, the controller activates an amine addition valve for a specified duration. The controller includes a time delay feature, allowing amine addition every two minutes.
Maintenance: Regular calibration of the pH sensor assembly is necessary. The system includes accessories such as a test meter, pH probe support, buffered solutions, and a carrying case to facilitate calibration. The sensor tip must remain in ink or water to prevent drying or damage, which would require replacement and recalibration.
Installation: The tank mount pH assembly can be attached to the lid of an ink pail or a viscosity measuring element. A mounting bracket, ordered separately, secures the sensor assembly to the pail cover.
Contact Information: Norcross Corporation, 255 Newtonville Ave., Newton, MA 02458 USA. Phone: (617) 969-7020, Fax: (617) 969-3260, Email:
[email protected]. For international inquiries, Phone: (203) 230-4130, Fax: (203) 248-8093, Email:
[email protected]. Website:
www.viscosity.com.