IMED
16Pages

{{requestButtons}}

Catalog excerpts

IMED - 1

IMED Medical Power Supplies and Accessories

Open the catalog to page 1
IMED - 2

NORATEL When performance matters. NORATEL – one of Europe's biggest manufacturers of transformers In 1925 Noratel started the production of radios, transmitters and receivers as “Norsk Radio Telefon og Telegraf A/S”. Nowadays Noratel belongs with 2400 employees in 13 countries and yearly revenues of approx. 100 million Euros to the leading manufacturers of transformers. Since 10 years now, Noratel Germany AG, founded in 2001, supplies a very special market: Power supplies and accessories for the medical market. In the meantime, besides the standard range of 20 different IMED models between...

Open the catalog to page 2
IMED - 3

The recent medical technology with its increasing number of electric devices, combined to a system, necessitates turning one's special attention to its power supply conforming to the law. IMED Medical Power Supplies and Accessories Both the manufacturer of such a system and the system operator are responsible for meeting the statutory provisions. All IMED products have especially been designed for the use in the medical technology. They are indispensable tools to meet the safety requirements of the medical devices directive and the corresponding device and system standards (EN60601-1 and...

Open the catalog to page 3
IMED - 4

The currently valid EU medical product directive (93/42/EEC with amendment 2007/47/EC) imperatively determines that medical devices and systems have to be designed in a way that patients, operating personnel or other persons may not suffer while being in contact with those. Important tools to meet the safety requirements This generates strict requirements for the safety of the power supply of electrical medical devices and systems. Especially medical electrical systems for life support and monitoring life functions require very high reliability and quality of their power supplies. Increased...

Open the catalog to page 4
IMED - 5

The use of medical isolating transformers for the power supply of electrical devices and systems, used in medical protected zones, offers a well-priced possibility to follow the EU medical product directive and to ensure the electrical safety for the power supply in a medical environment. Our development and production are controlled through a quality management system according to DIN EN ISO 9001 supervised by Intertek. Regarding the medical technology according to DIN EN ISO 13485 we are inspected by MDC. Additionally we keep an environmental management system according to DIN EN ISO...

Open the catalog to page 5
IMED - 6

IMEDe series (euro series) IMEDi series (international serie) Medical Isolating Transformers IMEDe IMEDi This series of medical isolating transformers is offered in two different versions. The IMEDe series was designed especially for the use within Europe. Therefore, it is working with a fix input and output voltage of 230 V~. The IMEDi series can be used in areas with 115 V~ and 230 V~ system voltage. Its voltage levels, which can be adjusted separately on the primary and secondary side, allow additional voltage adjustments. The protective earth conductor of the input socket is...

Open the catalog to page 6
IMED - 7

Technical data IMEDe series IMEDe 150 Weight (without packing) kg Output sockets Housing protection class Input and output voltage Device leakage current (primary) Output leakage current (secondary) Inrush current limiter thermal semiconductor Short circuit protection m icro fuse primary Excess temperature protection s elf resetting temperature switch Housing design s heet steel housing, powder-coated, light-grey RAL7035 Mains cable primary Mounting possibility fl oor, table or wall mounting floor or table mounting (no wall mounting) EN 60601-1, EN 60601-1-1, EN 60601-1-2, EN 61558-1, EN...

Open the catalog to page 7
IMED - 8

IMEDe series 3rd Edition (euro series) IMEDi series 3rd Edition (international series) The New Medical Isolating Transformers The medical isolating transformers IMED 3rd Edition have been designed for the power supply of high reliable medical electrical systems (ME systems). These are ME systems which may not fail at all even in the case of major interferences of the supply voltage. The power supply of such ME systems has to be immune especially against half-wave failures. Without special arrangements, these may lead to high over-currents in the isolating transformer. As a consequence of...

Open the catalog to page 8
IMED - 9

Technical data IMEDe series 3rd Edition Output sockets Housing protection class Weight (without packing) kg Dimensions (L x W x H) mm Input and output voltage Device leakage current (primary) Output leakage current (secondary) Inrush current limiter electronic at nominal current value Short circuit protection m icro fuse primary Excess temperature protection self resetting temperature switch Housing design sheet steel housing, powder-coated, light-grey RAL7035 Mains cable primary Mounting possibility floor, table or wall mounting with optional accessory EN 60601-1 (3rd Edition), EN...

Open the catalog to page 9
IMED - 10

MLI-1000 (Gigabit-Ethernet 1000 MBit/s) Medical LAN-Isolator Conformity approved by certification body "SLG Prüf- und Zertifizierungs GmbH" The medical LAN Isolator MLI 1000 is the solution for a serious problem in cable supported IT networks and network segments within medical safety areas. It is the missing link in the chain ofm necessary insulating measures when using modern data networks in medical areas. MLI All IT devices (devices of the information technology such as computers, printers, network servers etc.), that are interconnected by Ethernet cable, show a direct electrical...

Open the catalog to page 10
IMED - 11

ELG ELGS ELGT Earth Leakage Guard The earth leakage guards of the ELG-series controls the dielectric resistance between the medical supply circuit and the earth potential. The typically arranged protective measures against insulation fault on the building power supply (such as ground fault circuit breaker) may not principally identify possible insulation defects on the output side due to the galvanic insulation through the IMED isolating transformer. This leads to a potential danger for the patients or the operating personnel. The earth leakage guards of the ELG-series close this security...

Open the catalog to page 11

All Noratel China Ltd catalogs and technical brochures