Overview: The document is a datasheet for the NT 2400 series multi-zone temperature controllers by Nolden Regelsysteme GmbH, designed primarily for the plastic moulding industry. These controllers are available in 4, 6, or 8-zone configurations and are optimized for hot-runners, extruders, and presses.
Specifications:
  • Mains Voltage: 230V~ ±10%, 48...62Hz
  • Control Zones: NT2404 (4 zones), NT2406 (6 zones), NT2408 (8 zones)
  • Control Output: Heating: 18V DC, max. 10mA; Cooling: floating relay contact (3-point operation only)
  • Alarm Output: Relay, floating, max. 250V~, 3A
  • TC-input: Configurable for Pt100, Fe-CuNi Typ J, NiCr-Ni Typ K
  • Display: High contrast graphic LCD, blue
  • Dimensions: 96 x 96mm housing, depth 122mm
  • Protection: IP20; Front: IP50
  • Operation Conditions: Environmental temperature 0... 50°C
Features:
  • Microprocessor Control: Includes automatic self-tuning to adapt control parameters for each heating zone.
  • Operation: User-friendly interface with language options in German or English, featuring menus and soft-keys for easy programming.
  • Alarm Functions: Each zone has two alarm functions for process-high and cable-breakage warnings.
  • Graphic Tracing Function: Allows monitoring of real-time values for each zone.
  • Manual Power Control: Zones can be switched to manual control even if sensors are operational.
  • Soft-start Feature: Preserves cold heating elements with adjustable time, power, and temperature settings.
  • Second Set-point: Allows switching to a standby operation mode via an external contact.
Optional Features:
  • Heater Current Monitoring: With current transformer M2000 for 35mm rails.
  • Interface Options: RS485, RS232, TTY 0/20mA, CANopen, CiA Device Profile DS-404.
See more

Catalog excerpts

NT 2400-1

DIN Temperature controller NOL-DEN 96x96 multi zone NT 2400__ 4-, 6-, 8-zone-temperature controller • Microprocessor multi zone controller with LED-Display • Optimized for use in the plastic moulding industry • Clearly arranged overview of all relevant parameters : All in one sight • Automatic self-tuning - adapts to different controlled systems • Graphical tracing-function for the actual parameters Application This temperature controller unit was specially designed to fit the demands of the plastic moulding industry. It comes up with a clear design and provides easy operation, good overview on all zones and various self-monitoring features. The controller is mainly used for hot-runners, but also for extruders and presses. Multi zone controller (4, 6, 8 zones) in norm format 96 x 96mm for cabinet front panel integration. Closed loop control Microprocessor-controller with automatic self-tuning: Automatically determines the characteristics of each heating-zone and adapts the control-parameters accordingly. Easily understandable operation panel in German or English with menus and soft-keys. Simple programmation of the controller by different menu levels, easy and safe. Alarm output Each heating zone provides 2 separated alarm functions, which are wired to 2 floating contacts and operate as a common alarm output. One alarm is pre-defined as process-high- and one as cable-breakage-warning. Graphic tracing-function For every zone, the development of the real values can be indicated. Safeguard in case of sensor-breakage Sensor-breakage is signalled at the zones corresponding display. The concerned zone switches-over to manual power-control and takes over the last assigned value, which may be adjusted manually. Manual power-control Each heating zone may be changed to manual power control even if the sensor is working. NOLDEN REGELSYSTEME GMBH All rights reserved Revision: 11/2010 Gewerbegebiet Am Tonschuppen 2 Tel.: 0049-228-644856 E-Mail: [email protected] 53347 Alfter-Volmershoven Fax: 0049-228-640309 Internet: www.nolden-regler.de

 Open the catalog to page 1
NT 2400-2

DIN Temperature controller 96x96 multi zone NT 2400 Limitation of desired temperature value To prevent misuse or faulty entries, minimum- as well as maximum- temperature-values can be programmed. Automatic self-tunig The controller starts-up (if desired) with a soft-start to preserve cold heating elements. Time, power-setting and temperature during this phase are variable and can be set-up for every zone as needed. Analysis of characteristics of the controlled systems at start-up, can also be triggered manually during operation. Picture: Detailled info per zone (effective control parameters)...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.