NT 1100

NT 1100

NT 1100

Product catalog summary
Overview: The NT 1100 is a single-zone temperature controller designed by Nolden Regelsysteme GmbH, optimized for the plastic moulding industry. It features a microprocessor with an LED display and is available as a 2- or 3-point controller with automatic self-tuning capabilities.
Application: This controller is specifically designed for use in hot-runners, extruders, and presses within the plastic moulding industry. It offers easy operation and self-monitoring features.
Design: The controller is a single-zone unit with a standard 96 x 96mm size for cabinet front panel integration.
Functionality: The NT 1100 uses closed-loop control with automatic self-tuning for optimal performance. It includes a sensor-breaking guard that switches to manual power control in case of sensor failure. Alarm contacts are configurable, with two available for 2-point controllers and one for 3-point controllers.
Specifications:
  • Mains Voltage: 230V~ ±10%, 48...62Hz
  • Control Output: Heating via 18V DC for SSR or relay control; Cooling via floating relay contact (3-point operation only)
  • Alarm Output: Relay, floating, max. 250V~, 3A
  • TC-input: Configurable for Pt100, Fe-CuNi Typ J, NiCr-Ni Typ K with internal zero point correction
  • Temperature Range: Fe-CuNi (J) 0...800°C, NiCr-Ni (K) 0…999°C, Pt100 various ranges
  • Display: 7-segment LED, 10mm red
  • Memory Type: EAROM
  • Electrical Connection: Terminal strip following DIN 40050
  • Dimensions: 96 x 96mm housing, depth 67mm, IP20 protection, front IP50
  • Weight: Approximately 400g
  • Operating Conditions: Environmental temperature 0...50°C
See more

Catalog excerpts

NT 1100-1

NOLDEN Single-zone-temperature controller • Microprocessor single zone controller with LED-Display • Optimized for use in the plastic moulding industry • Automatic self-tuning - adapts to different controlled systems This temperature controller unit was specially designed to fit the demands of the plastic moulding industry. It comes up with a clear design and provides easy operation and various selfmonitoring features. The controller is used for hot-runners, extruders and presses. Single zone controller in norm-format 96 x 96mm for cabinet front panel integration. Microprocessor-controller with automatic self-tuning establishes best control-results for fast nozzles as well as for slow manifolds or extruders. In the case of a sensor-breakage, the controller switches over to manual power-control and effects the last used power set-point. Depending on the configuration, two alarm contacts are available : 2 Alarm contacts available 1 Alarm contact available The function of the alarms can be set-up in the menu. NOLDEN REGELSYSTEME GMBH All rights reserved Revision: 11/2010 Gewerbegebiet Am Tonschuppen 2 Tel.: 0049-228-644856 E-Mail: [email protected] 53347 Alfter-Volmershoven Fax: 0049-228-640309 Internet: www.nolden-regler.de

 Open the catalog to page 1
NT 1100-2

NOLDEN Example for the wiring : Mains voltage Control output 18V DC, max. 10mA, short-circuit proof for the control of a solid state relay (SSR) or floating relay contact for relay control (Art.-Nr. 82081.9) floating relay contact (only 3-point-operation) Alarm output • NiCr-Ni Typ K DIN IEC 584 internal zero point correction Thermocouple is monitored for cable breakage and short-circuit. Temperature range Electrical connection Terminal strip following DIN 40050 Housing 96 x 96mm for cabinet front-panel integration following DIN 43700, depth 67mm Protection: IP20; Front: IP50 Operation conditions...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.