Signal converter 641
2Pages

{{requestButtons}}

Catalog excerpts

Signal converter 641 - 1

Signal converter 641 • Current inputs 0/4..20 mA • Voltage inputs 0..5, 0..10 V, ± 10V • Potentiometer • Output 0/4..20 mA, 0..5/10 V, ± 10V, or passive 2-wire output 4-20 mA • Power supply for 2-wire transmitter • Galvanic isolation • Four selectable dampings • Nominal accuracy 0.05 % of range • Power supply 24 VDC ± 10% • mV-inputs on request Signal converter 641 is designed to convert standard process input /output signals. Current inputs 0/4..20 mA can be converted into voltage outputs, -10..+10 V can be converted to 0..10 V, low mV inputs can be converted to standard outputs etc. Signal converter 641 accepts 2-wire transmitters without a separate power supply. Potentiometer input as a standard. Galvanic isolation is made at the same time with the convertion. Galvanic isolation cuts the noise signals which may exist when using low voltage signals, e.g. thermocouples. 0.±5 V, 0..±10 V or current 0/4..20 mA. Converter 641 gives also the possibility to signal damping. There is four selectable dampings: 10 ms, 250 ms, 500 ms or 750 ms. Selecetion via DIP-switches. Operating voltage 24 VDC ± 10% is also isolated from input and output. The common inputs and outputs are selected via DIP-switches, see table next page. Fine adjustment is made with front panel zero and span potentiometers. The ranges, not given in the table, may be delivered on request. Signal converter 641 is delivered always to ordered range. Output selectable via DIP-switches: voltage 0-5V, 0-10V, Power supply 24 VDC isolated from input and output Output: 0...20 mA 4..20 mA 0...5 V 0...10 V +-10V 20..4 mA (reversed) 2-wire output 4-20 mA (passive output) 2-wire transmitter without external power supply Power supply 24 VDC isolated from input and output DIP-switches for range selection

Open the catalog to page 1
Signal converter 641 - 2

Technical specifications: Accuracy Typical linearity Temperature effects: Input resistance < 0,05% of range < 0.05 % of range under 0.006% /°C 50 W for current > 100 MW for voltage input Potentiometer 500W - 100 kW Output load Max. 600 W Power supply 24 VDC ± 10 % Isolation >1000 V input-output Power 40 mA, voltage output consumption 60mA, mA-output 80 mA, 2-wire transmitter Range selection DIP-switches and jumpers Damping Four selectable dampings T=63% 0,1 ms, 250 ms, 500 ms and 700 ms Rise time 100% 300 µs Frequency response 10 ms, 0...1 kHz, ± 10V input/output Ambient temp. 45°C Case...

Open the catalog to page 2

All Nokeval catalogs and technical brochures

  1. MTR265B

    15 Pages

  2. RTR970B-PRO

    36 Pages

  3. FTR262

    12 Pages

  4. OVAHYGI

    1 Pages

  5. OVATERM

    1 Pages

  6. 6420

    2 Pages

  7. 6740

    2 Pages

  8. 7100

    2 Pages

  9. 6841

    2 Pages

  10. 6720

    2 Pages

  11. 620S

    2 Pages

  12. HTB230

    2 Pages

  13. 6570

    2 Pages

  14. 2028

    2 Pages

  15. 2041

    2 Pages

  16. PM20

    1 Pages

  17. PM10

    4 Pages

  18. 201

    1 Pages

  19. 538-8SC

    2 Pages

  20. PME600

    2 Pages

  21. 2000IP65

    2 Pages

Archived catalogs

  1. 6580

    2 Pages