Overview: The PME600 and PME610 panel meters are designed for temperature sensors and common process inputs. They feature low and high alarm relays, a compact design, and a wide power supply range.
Specifications:
  • Inputs: Pt100, thermocouple K, 4/20 mA, 0/10 V
  • Output: 4-20 mA (only PME610)
  • Power Supply: 21-265 VAC/DC, with 12 VDC for 2-wire transmitters (PME600)
  • Panel Size: 48 x 96 mm, 65 mm depth
  • Display: 4-digit bright red LED
  • Accuracy: 0.05% of span for process inputs
  • Temperature Range: -200 to +700°C for Pt100, -150 to 1350°C for thermocouple K
Features:
  • Two alarm relays for low and high alarms with adjustable hysteresis
  • Non-galvanic isolated analog output suitable for isolated input signals
  • Easy configuration via front panel buttons
  • IP65 rated front panel for protection
Additional Options: For more functions, models 2012 and 2021 offer features like galvanically isolated output, changeover alarm relays, and RS485 serial output.
General Information:
  • Operation Temperature: -10 to +60°C
  • Weight: 146 g
  • EMC: CE marked
See more

Catalog excerpts

PME600-1

www.nokeval.com [email protected] PME600 and PME610 panelmeters for process inputs and temperature sensors • Pt100, thermocouple K, 4/20 mA, 0/10 V • 2 alarm relays, low and high alarm • Power supply 12 VDC for 2-wire transmitter • Output 4-20 mA (PME610) • Panel size 48 x 96 mm, only 65 mm deep • Wide power supply range 21..265 V AC or DC Place for engineering unit The panelmeter PME600 series is designed especially for temperature sensors and for the most common process inputs. Low and high alarm relays are as standard. The model 600 includes power supply 12 VDC for two wire 4-20 mA transmitter and the 610 includes output 4-20 mA. The analog output 4-20 mA is not galvanic isolated from input signal and therefore it is suitable for those applications where input signal is isolated like Pt100 sensors. The enclosure is only 65 mm deep and therefore it is suitable also for small enclosures. The panel meters are easy to configurate by using buttons in the front panel. There is only one power supply for wide voltage range covering the range of 21..265 AC or DC. This feature saves stocking and maintenance costs. Universal power supply 21..265 VAC/DC High alarm relay Output 4-20 mA Only model PME610 Model PME600 includes 12VDC power supply for 2-wire transmiter 4-20 mA Analog output is connected to common with analog input In case you need more options, please see model 2012 and 2021 which indule more functions and options like galvanically isolated output, change over alarm relays, RS485 serial output etc.

 Open the catalog to page 1
PME600-2

Process input: Display range Input resistance Sensor current: Temp, coffient: Cold junction: Line resistance 70 ohm, connected only when power 110 kOhm for voltage input Relay contacts: Input filter: Sample speed: Alam lights: Power suppy: Front panel: Operation temp. Adjustable (same for both of alarms) closing contacts (resistive load) Floating average of three samples Range Scaleable Order code: Special functions: 12 VDC power supply for transmitter Terminal connections: alarm alarm Power supply

 Open the catalog to page 2

All Nokeval catalogs and technical brochures

  1. MTR265B

    15  Pages

  2. RTR970B-PRO

    36  Pages

  3. FTR262

    12  Pages

  4. OVAHYGI

    1  Page

  5. OVATERM

    1  Page

  6. 6420

    2  Pages

  7. 6740

    2  Pages

  8. 7100

    2  Pages

  9. 6841

    2  Pages

  10. RMD680/RMD681

    2  Pages

  11. 6720

    2  Pages

  12. 620S

    2  Pages

  13. HTB230

    2  Pages

  14. 6570

    2  Pages

  15. 2028

    2  Pages

  16. 2041

    2  Pages

  17. PM20

    1  Page

  18. PM10

    4  Pages

  19. 201

    1  Page

  20. 538-8SC

    2  Pages

  21. Bulletin 2072

    2  Pages

  22. 2000IP65

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.