Catalog excerpts
sales@nokeval.com www.nokeval.com 2-wire transmitter HTB230 for RTD sensor • Resistor sensors Pt100, Ni100, Cu10 • 3- or 4-wire installation • Input converter 24 bit • Output signal 2-wire 4-20 mA • Output conversion 16 bit • Freely scalable output • 2 point calibration option • operating temperature -40...+85°C • Accuracy 0.05% from reading +0.1°C • Excellent stability • USB connection in programmer • MekuWin configuration program for PC The 2-wire transmitter designed for sensor case installation is easily programmable to different resistor type sensors. Programmer can be connected directly to a USB port where it takes the operational energy so the additional power supply is not required. The transmitter is configurated using multi purpose configurationsoftware MekuWin. MekuWin is compatible with all Nokeval’s intelligent instruments. The wide operational temperature range -40..+85°C makes it possible to use the transmitter almost in any industrial enviroment. Transmitter has exeptionally good input and output resolution (24 bit input and 16 bit output). Excellent stability guarantees longterm accuracy. If needed, the transmitter can be calibrated in one or two points. Transmitter has been fully tested in our EMC-laboratory in Nokia to be as immune as possible to different type of distortions. The transmitter exceeds the required standards and is CE-approved. Configurating is made using additional USB-port connected programmer. The programmer is connected using crocodile clips to transmitters out putconnectors. Settings are done using easy and versatile programming software MekuWin. It is possible to download MekuWin software from www.nokeval.com. Field enclosure is available with or without Pt100 sensor (option). Enclosure size is 58 x 65 x 35 mm (WHD), IP65, gland(s) PG11. Transmitter can be installed to DIN rail (35 mm) by using HTB-DIN bracket. Programming is fast and easy using MekuWin cofiguration program. Programmer takes it’s power from USB connectoin from PC. No a
Open the catalog to page 1Output signal Voltage: Current range: Accuracy: Thermal drift: Sensor fault: A/D conversion D/A conversion Speed of update Startup time Operating temperature Operating voltage Connection terminals Installation Weight EMC immunity EMC emissions Marks Programming Programmer Configurating software Resistive sensor Pt100 Accuracy 0.05% from reading +0.1°C Accuracy 0.05% from reading +0.1°C Accuracy 0.05% from reading +0.1°C Accuracy 0.1% from reading +1 ohm General information: 24 bit (input signal) 16 bit (output signal) 2.5 measures / s 1 s (4% from the final value) 1.5 s...
Open the catalog to page 2All Nokeval catalogs and technical brochures
-
Loop Powered Isolator 6570
2 Pages
-
MTR265B
15 Pages
-
RTR970B-PRO
36 Pages
-
Ovasense Neo Series
6 Pages
-
FTR262
12 Pages
-
Ovazone-Flex series
1 Pages
-
OVAHYGI
1 Pages
-
OVATERM
1 Pages
-
6420
2 Pages
-
6740
2 Pages
-
7100
2 Pages
-
6841
2 Pages
-
RMD680/RMD681
2 Pages
-
6720
2 Pages
-
620S
2 Pages
-
6570
2 Pages
-
2028
2 Pages
-
2041
2 Pages
-
PM20
1 Pages
-
PM10
4 Pages
-
Signal converter 641
2 Pages
-
541 Setpoint transmitter
2 Pages
-
201
1 Pages
-
538-8SC
2 Pages
-
PME600
2 Pages
-
Bulletin 2072
2 Pages
-
2251 Panelmeter
2 Pages
-
2000IP65
2 Pages
Archived catalogs
-
6580
2 Pages
-
Wireless Transmitters 2011
24 Pages
-
910E5-2012 Process Inputs
2 Pages
-
Multipoint Indicator 538-8SC
2 Pages
-
2212 Panelmeter
2 Pages
-
Panel meters 2012
2 Pages