HTB230

HTB230

HTB230

Product catalog summary
Overview: The HTB230 is a 2-wire transmitter designed for RTD sensors, compatible with Pt100, Ni100, and Cu10 resistor sensors. It supports 3- or 4-wire installations and features a 24-bit input converter with a 16-bit output signal, providing a 4-20 mA output. The device is programmable via USB using the MekuWin configuration software.
Specifications:
  • Input: Resistor sensors (Pt100, Ni100, Cu10), 3- or 4-wire installation.
  • Output: 2-wire 4-20 mA, freely scalable, with 16-bit conversion.
  • Accuracy: 0.05% from reading +0.1°C.
  • Operating Temperature: -40 to +85°C.
  • Power Supply: 6.5 to 30 VDC.
  • EMC Compliance: EN61326, CE-marked.
Features:
  • USB connection for programming, no additional power supply needed.
  • Configuration via MekuWin software, compatible with all Nokeval instruments.
  • Wide operational temperature range suitable for various industrial environments.
  • High input and output resolution ensures excellent stability and long-term accuracy.
  • Optional 1 or 2-point calibration.
Installation and Configuration:
  • Can be installed in B and Buz sensor casings or on a DIN rail using the HTB-DIN bracket.
  • Programming is done using the HTB-PROG programmer connected to a USB port.
  • Settings are configured using the MekuWin software, downloadable from the Nokeval website.
Technical Specifications:
  • Pt100 Sensor: Accuracy 0.05% from reading +0.1°C, thermal drift 0.01°C/°C.
  • Ni100 Sensor: Measurement range -60 to +180°C, accuracy 0.05% from reading +0.1°C.
  • Cu10 Sensor: Measurement range -200 to +260°C, accuracy 0.05% from reading +0.1°C.
  • Ohm Measurement: Range 0 to 2000 ohm, accuracy 0.1% from reading +1 ohm.
  • Output Signal: Voltage 6.5 to 30 VDC, current range 3.5 to 23 mA, accuracy ±8 µA at 25°C.
Additional Information:
  • Startup time is 1 second to 4% of the final value, 1.5 seconds to fully stabilize.
  • Weight: 30g.
  • Field enclosure available with or without Pt100 sensor, size 58 x 65 x 35 mm, IP65 rated.
See more

Catalog excerpts

HTB230-1

[email protected] www.nokeval.com 2-wire transmitter HTB230 for RTD sensor • Resistor sensors Pt100, Ni100, Cu10 • 3- or 4-wire installation • Input converter 24 bit • Output signal 2-wire 4-20 mA • Output conversion 16 bit • Freely scalable output • 2 point calibration option • operating temperature -40...+85°C • Accuracy 0.05% from reading +0.1°C • Excellent stability • USB connection in programmer • MekuWin configuration program for PC The 2-wire transmitter designed for sensor case installation is easily programmable to different resistor type sensors. Programmer can be connected directly to a USB port where it takes the operational energy so the additional power supply is not required. The transmitter is configurated using multi purpose configurationsoftware MekuWin. MekuWin is compatible with all Nokeval’s intelligent instruments. The wide operational temperature range -40..+85°C makes it possible to use the transmitter almost in any industrial enviroment. Transmitter has exeptionally good input and output resolution (24 bit input and 16 bit output). Excellent stability guarantees longterm accuracy. If needed, the transmitter can be calibrated in one or two points. Transmitter has been fully tested in our EMC-laboratory in Nokia to be as immune as possible to different type of distortions. The transmitter exceeds the required standards and is CE-approved. Configurating is made using additional USB-port connected programmer. The programmer is connected using crocodile clips to transmitters out putconnectors. Settings are done using easy and versatile programming software MekuWin. It is possible to download MekuWin software from www.nokeval.com. Field enclosure is available with or without Pt100 sensor (option). Enclosure size is 58 x 65 x 35 mm (WHD), IP65, gland(s) PG11. Transmitter can be installed to DIN rail (35 mm) by using HTB-DIN bracket. Programming is fast and easy using MekuWin cofiguration program. Programmer takes it’s power from USB connectoin from PC. No a

 Open the catalog to page 1
HTB230-2

Output signal Voltage: Current range: Accuracy: Thermal drift: Sensor fault: A/D conversion D/A conversion Speed of update Startup time Operating temperature Operating voltage Connection terminals Installation Weight EMC immunity EMC emissions Marks Programming Programmer Configurating software Resistive sensor Pt100 Accuracy 0.05% from reading +0.1°C Accuracy 0.05% from reading +0.1°C Accuracy 0.05% from reading +0.1°C Accuracy 0.1% from reading +1 ohm General information: 24 bit (input signal) 16 bit (output signal) 2.5 measures / s 1 s (4% from the final value) 1.5 s (fully...

 Open the catalog to page 2

All Nokeval catalogs and technical brochures

  1. MTR265B

    15  Pages

  2. RTR970B-PRO

    36  Pages

  3. FTR262

    12  Pages

  4. OVAHYGI

    1  Page

  5. OVATERM

    1  Page

  6. 6420

    2  Pages

  7. 6740

    2  Pages

  8. 7100

    2  Pages

  9. 6841

    2  Pages

  10. RMD680/RMD681

    2  Pages

  11. 6720

    2  Pages

  12. 620S

    2  Pages

  13. 6570

    2  Pages

  14. 2028

    2  Pages

  15. 2041

    2  Pages

  16. PM20

    1  Page

  17. PM10

    4  Pages

  18. 201

    1  Page

  19. 538-8SC

    2  Pages

  20. PME600

    2  Pages

  21. Bulletin 2072

    2  Pages

  22. 2000IP65

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.