6740

6740

6740

Product catalog summary
Overview: The document provides detailed technical specifications and operational guidelines for the Nokeval 6740 programmable transmitter. This device is designed to accommodate a wide range of sensor inputs and is configurable via PC or a handheld programmer.
Specifications:
  • Sensor Compatibility: Supports thermocouples (types B, C, D, E, G, J, K, L, N, R, S, T), RTDs (Pt100, Pt500, Pt1000, Ni100, Ni1000), process inputs (0..20mA, 4..20mA, -20..+20mA, 0..5V, 0..10V, -10..+10V), IR-thermocouples, and mV inputs (-100..+100mV).
  • Outputs: Provides outputs of 0..20mA, 4..20mA, 0..5V, and 0..10V.
  • Power Supply: Operates on a 24VDC power supply.
  • Accuracy and Linearity: Features a 16-bit A/D converter with high accuracy and linearity, ensuring precise measurements.
  • Galvanic Isolation: Ensures isolation between input, output, and power supply, crucial for thermocouple applications.
Configuration and Programming:
  • Configurable via PC using a menu-based program or with a handheld programmer (model 6790).
  • Features a configuration connector for easy connection to a PC's serial port.
Technical Details:
  • Thermocouple Ranges: Various ranges and linearity specifications are provided for each thermocouple type.
  • RTD Specifications: Includes range, sensor connections, and accuracy details for Pt100, Pt500, Pt1000, and Ni100 sensors.
  • Process Inputs: Details on input impedance, accuracy, and linearity for current and voltage inputs.
  • Construction: Compact design with detachable connectors for easy installation and programming.
General Information:
  • Operating Conditions: Suitable for temperatures between 0..60°C and storage between -20..+70°C, with humidity tolerance up to 95% RH (non-condensing).
  • Protection and Weight: IP20 protection with a weight of 80g.
Ordering Information: Includes optional accessories such as the POL-RS232 cable, configuration software (MekuWin), and handheld programmer (6790).
See more

Catalog excerpts

6740-1

www.nokeval.com [email protected] • Thermocouples B,C,D,E,G,J,K,L,N,R,S,T • RTD's Pt100, Pt500, Pt1000 ja Ni100, Ni1000 • Process inputs: 0..20mA, 4..20 mA, -20 .. +20 mA 0..5 V, 0..10 V, -10 .. +10 V • IR-thermocouples • mV-inputs -100 .. +100 mV • Outputs: 0..20, 4..20 mA, 0..5, 0..10 V • Programming by PC or hand held programmer 6790 • Galvanic isolation, input/output/power supply • Power supply 24VDC Technical specification: Signal converter 6740 is exceptionally versatile and accepts almost all common sensor inputs. You can configure it by PC. Transmitter front has configuration connector which connects adapter cable POL-RS232 to serial port of the PC. Menu based configuration program is easy to use. By hand held programmer 6790 you can easily control or configurate the transmitter in field conditions. The 16 bit A/D converter enables high accuracy. Linearity of A/ D converter is 0.005 % and conversion accuracy of output signal is 0.05 %, without sensor linearization error. Galvanic isolation is specially important with thermocouples but potential differencies with other measuring circuits can be avoided also in case of process input signals. Small size converter is provided with detachable connectors which speed up installation and programming. Large sensor selection and other inputs as well as versatility reduce stocking costs significantly because the 6740 suits for most measuring applications. Thermocouples: Sensor Range Calibration accuracy < 0.1 % of max. span Cold junction compensation< 0.05 °C / °C Sensor wire influence < 10 kohm, negligible RTD's: Range Converter 6740 construction Sensor connections Max. sensor wire resistance Sensor current Accuracy Calibration accuracy Linearity Sensor error correction Other resistance inputs 0-1000 ohm, potentiometer 50-500 ohm mV-inputs: Accuracy Linearity input impedance Process inputs: Input impedance Accuracy Linearity Emissivity correction Exergen 140F-K and 440F-K -40...+350°C (linearized range) -

 Open the catalog to page 1
6740-2

Output: Output Output scaling 0..20, 4..20 mA, 0..5 V, 0..10V scaling on whole range, straight and reversed < 0.03 % of span (DAC) <0.05% of span 3.5 or 24 mA or >10V 24 mA <600 Ω for current and >10 kΩ for voltage Resolution Calibration accuracy Sensor break monitoring Output limiter Output load Model Sensor input Range Output Example. Configuration: Connection 2-pole Nokeval POL-connection (transmitter) RS232, 9600bps, 9-pole D-connector by PC's serial port Meku / Nokeval 6790, red LED-display Serial data Serial protocol Hand held programmer General: Power supply Power consumption Temperature...

 Open the catalog to page 2

All Nokeval catalogs and technical brochures

  1. MTR265B

    15  Pages

  2. RTR970B-PRO

    36  Pages

  3. FTR262

    12  Pages

  4. OVAHYGI

    1  Page

  5. OVATERM

    1  Page

  6. 6420

    2  Pages

  7. 7100

    2  Pages

  8. 6841

    2  Pages

  9. RMD680/RMD681

    2  Pages

  10. 6720

    2  Pages

  11. 620S

    2  Pages

  12. HTB230

    2  Pages

  13. 6570

    2  Pages

  14. 2028

    2  Pages

  15. 2041

    2  Pages

  16. PM20

    1  Page

  17. PM10

    4  Pages

  18. 201

    1  Page

  19. 538-8SC

    2  Pages

  20. PME600

    2  Pages

  21. Bulletin 2072

    2  Pages

  22. 2000IP65

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.