www.nokeval.com sales@nokeval.com 2022TANK Level and volume indicator • Available for panel or wall mounting • Process input 0/4..20 mA, 0..5/10 V • 10 point linearization gauge signal to level • 32 point linearization level to volume • 6-digit LED display • Configuration via front panel keys or serial port • 2 or 3 alarm relays • Serial communications RS-232 and RS-485 • Wide power supply range 85..240 VAC or 12..32 VDC / 24 VAC • Case protection rating IP65 2022TANK indicator is designed for liquid tank applications. It is connected to a tank level transmitter with a mA or V signal. The indicator can feed a level transmitter with a 24 V 150 mA supply. This mA or V signal is linearized to a level reading using up to ten free linearization points. They are mA - level pairs. Any of the points can be edited afterwards. The level can be expressed in any unit, e.g. mm or m or inches. Liquid volume is then acquired from the level reading using up to 32 free linearization points. These are simply level - volume pairs. Again, the volume can be expressed in any unit. The six-digit display allows displaying readings up to 999 999. The indicator can be configured using the front panel or alternatively using a serial connection and a free software Mekuwin. The serial connection allows to read the level and volume using Nokeval SCL protocol, whose specifications are available to everyone. The serial connection is on an option card. The meter can be equipped with two or three alarm relays using an option card. This meter is a part of the 2000 series. It is available as a 96x48 mm panel meter with 14 mm digits (2022TANK) or in a wall-mounted IP65 enclosure with 20 mm digits (28002022TANK). Blink Serial
Open the catalog to page 1Specifications: Input Galvanic isolation Update rate 0/4-20 mA input Input resistance Physical range Calibr accuracy Linearity Tempco Transmitter supply Input 0-5/10V Input resistance Physical range Calibr accuracy Linearity Tempco Serial communications Ports Galvanic isolation Protocol Baud rates Response Alarm relays Ratings Supply voltage “24VDC” option “230VAC” option Power Pre-fuse 12…36 VDC or 22…28 VAC 85-260 VAC or VDC 12 W Internal; if external is used, min 2A for 24VDC or 500mAT for 230VAC. Environment Oper temp Humidity How to order Panelmeter 2022TANK-RS-REL2-230VAC Field...
Open the catalog to page 2All Nokeval catalogs and technical brochures
-
Loop Powered Isolator 6570
2 Pages
-
MTR265B
15 Pages
-
RTR970B-PRO
36 Pages
-
Ovasense Neo Series
6 Pages
-
FTR262
12 Pages
-
Ovazone-Flex series
1 Pages
-
OVAHYGI
1 Pages
-
OVATERM
1 Pages
-
6420
2 Pages
-
6740
2 Pages
-
7100
2 Pages
-
6841
2 Pages
-
RMD680/RMD681
2 Pages
-
6720
2 Pages
-
620S
2 Pages
-
HTB230
2 Pages
-
6570
2 Pages
-
2028
2 Pages
-
2041
2 Pages
-
PM20
1 Pages
-
PM10
4 Pages
-
Signal converter 641
2 Pages
-
541 Setpoint transmitter
2 Pages
-
201
1 Pages
-
538-8SC
2 Pages
-
PME600
2 Pages
-
Bulletin 2072
2 Pages
-
2251 Panelmeter
2 Pages
-
2000IP65
2 Pages
Archived catalogs
-
6580
2 Pages
-
Wireless Transmitters 2011
24 Pages
-
910E5-2012 Process Inputs
2 Pages
-
Multipoint Indicator 538-8SC
2 Pages
-
2212 Panelmeter
2 Pages
-
Panel meters 2012
2 Pages