1. Catalogs
  2. Nokeval
  3. 2-wire field indicator 311 for temperature sensors and process inputs

2-wire field indicator 311 for temperature sensors and process inputs

2-wire field indicator 311 for temperature sensors and process inputs

2-wire field indicator 311 for temperature sensors and process inputs

Product catalog summary
Overview: The document provides technical specifications and features of the Nokeval 311 two-wire field indicator, designed for temperature sensors and process inputs. It supports a wide range of sensor types, making it suitable for various temperature applications.
Specifications:
  • Sensor Compatibility: Supports RTD sensors (Pt100, Pt1000), thermocouples (types B, C, D, E, G, J, K, L, N, R, S, T), and process inputs (0/4-20 mA, 0-10 V).
  • Output: 2-wire output of 4-20 mA, with a freely scalable 4-digit LED display.
  • Configuration: Configurable via front panel with password protection.
  • Alarms: Includes 2 alarm relays, with model 312 offering additional alarm features.
  • Protection: Enclosure protection rated at IP65.
Features:
  • Power Supply: Operates on 10-28 VDC, can be connected directly to output terminals if output is not needed.
  • Display: Bright red LED display for clear visibility in various conditions.
  • Accuracy: High accuracy with a 16-bit AD-converter and a 12-bit output converter.
  • Isolation: Galvanically isolated inputs for interference rejection.
Performance:
  • Thermocouple Inputs: Various ranges and linearity specifications for different thermocouple types.
  • RTD Sensors: Supports Pt100, Pt500, Pt1000, and Ni100 with specific ranges and accuracies.
  • Process Inputs: Current and voltage inputs with high accuracy and linearity.
  • Infrared Sensors: Compatible with Exergen 140F-K and 440F-K sensors, with emissivity settings adjustable via the front panel.
General Information:
  • Operating Conditions: Operating temperature range of 0-60°C, storage temperature of -20 to +70°C, and humidity tolerance of 0-95% RH.
  • Dimensions and Connections: Detailed connection diagrams and dimensions provided for installation.
See more

Catalog excerpts

2-wire field indicator 311 for temperature sensors and process inputs-1

www.nokeval.com [email protected] 2-wire field indicator 311 for temperature sensors and process inputs • RTD sensors Pt100, Pt1000 • Thermocouples B, C, D, E, G, J, K, L, N, R, S or T • Process inputs 0/4..20 mA tai 0..10 V • 2-wire output 4..20 mA • Freely scaleable 4-digit bright LED display • Configuration via front panel • 2 alarm relays • 6 points xy linearisation for process inputs • Password for configuration • Enclosure protection IP65 The wide variety of sensor types makes the field indicator 311 ideal for all kind of temperature applications. Further, the 311 also accepts thermopile infrared sensors and process inputs 4-20 mA and 0-10 V. Sensor selections, display and output scalings are easy to do with front keys. You can also prevent accessing to the menu by setting a password. The two-wire indicator 311 saves installation and cable costs especially where the distances are long, as no separate power supply is needed . Though the output 4-20 mA is available as standard you can connect power supply 12-28 V directly to output terminals, if you do not need output. The 311 takes only 8 mA from 24 VDC power supply, when output is not used. The bright red LED display shows measuring values in all conditions replacing badly readable LCD displays. The 311 is a very accurate and stable indicator and transmitter. Therefore it can be used in all kind of applications demanding high accuracy. Input signal is measured with a 16-bit ADconverter giving resolution of 1/64000. Scaleable output uses a 12-bit converter giving resolution of 1/4000. If you need one or two alarms, model 312 is available. Only one alarm relay can be energized at a time. Alarms are indicated by red LEDs in the front panel. Input is galvanically isolated from output giving good rejection on interference. Input and output scaling can be set separately e.g. display range is 0..5000 and ouput 0..1000 for 4-20 mA. Case protection rating is IP65. 2-wire indicator with 4-20 mA output Display Inputs: RTD-sensors Thermocouples mA- and V-inputs Potentiometers IR-sensors Power supply Galvanically isolated inputs High alarm Low alarm Power supply 10-28V can be connected directly to output terminals when you do not n

 Open the catalog to page 1
2-wire field indicator 311 for temperature sensors and process inputs-2

Infrared-sensors: IR-sensor Exergen 140F-K and 440F-K Range 140F-K (60°C) -40..+350°C (linearized range) Range 440F-K (220°C) -30..+600°C (llinearized range) Emissivity settings by front panel Output 2-wire output 4-20 mA Output limiter 21 mA (typical) Sensor break indication 3.5 or 21 mA Calibration accuracy Cold junction effect Wire resistance effect Pt100-sensors Sensors Ranges Connection Sensor current Calibration accuracy Temperature effect Linearity Max. wire resistance RTD/potentiometer mV-input mV-range Accuracy Linearity Input resistance Process input Current Voltage Display scaling...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.