PTM82
1 /4Pages

PTM82

PTM82
1 /4Pages

Catalog excerpts

PTM82-1

Datasheet Digital Contact Gauge with Temperature Display PTM82 ■ Recording min./max. pressure ■ Dry capacitive ceramic sensor ■ Smallest measuring range: 0.. .50 mbar ■ Largest measuring range: 0.60 bar ■ Negative pressure measuring range: up to -1 bar The model PTM82 combines pressure and temperature measurement with a large, bright display. The digital contact gauge can still be easily read from a distance and therefore allows for a quick assessment of the process parameters. An analog output and two switch outputs widen the range of applications. The capacitive measuring principle in combination with a ceramic membrane is resistant to aggressive and abrasive media. The process connection is made of high-quality stainless steel 1.4404 and is therefore suitable for almost all media. All wetted components are food safe, making the unit ideal for use in beverage and process water applications. ■ Industrial water applications Noding Messtechnik GmbH • Oldenfelder Bogen 29 • D-22143 Hamburg, Germany • Tel.: 040 / 67 58 51 - 0 Fax: 040 / 67 58 51 - 49 • Internet: www.noeding-messtechnik.de • E-mail: info@noeding-messte

 Open the catalog to page 1
PTM82-2

PTM82 Datasheet Digital Contact Gauge ELECTRICAL CONNECTION TECHNICAL DATA Measuring range Pressure range See table „Measuring ranges pressure“ others on request Temperature range See table „Measuring ranges temperature“ others on request Output Analog output Contact output Connection with 1 analog output and 2 contact outputs brown Power supply 20 mA output Signal characteristics Accuracy pressure Long term stability pressure Accuracy temperature Response time Switch-on time Temperature coefficient Zero pressure Span pressure Temperature measurement gray blue Connection with 2 analog output...

 Open the catalog to page 2
PTM82-3

■ ORDERING CODE Analog output pressure 3 outputs are possible either 2 analog outputs + 1 contact output or 1 analog output + 2 contact outputs Analog output temperature Contact output pressure Contact output temperature Pressure ranges Measuring ranges see table 99 Non-standard range (on request) Temperature ranges Measuring ranges see table 9 Non-standard range (on request) Process connection and material R1 G1/2 right, ISO 228-1, 1.4404, protection tube 6 0 9 Others (on request) Temperature tube length Sensor seal 1 Pt 1000 Kl. B, display only 2 digits 3 Pt 1000 Kl. A, display only 2 digits...

 Open the catalog to page 3
PTM82-4

PTM82 Datasheet Digital Contact Gauge DIMENSIONS 80 Temperatrue tube lenght 02/2023 A - Modifications reserved without notice Nöding Messtechnik GmbH • Oldenfelder Bogen 29 • D-22143 Hamburg, Germany • Tel.: 040 / 67 58 51 – 0 Fax: 040 / 67 58 51 – 49 • Internet: www.noeding-messtechnik.de • E-mail: info@noeding-m

 Open the catalog to page 4

All Nöding Messtechnik catalogs and technical brochures

  1. TM63

    4  Pages

  2. PTM82

    4  Pages

  3. ERW 72.4

    2  Pages

  4. EMW 63.4

    2  Pages

  5. FM2

    3  Pages

  6. OFS9

    2  Pages

  7. P142

    3  Pages

  8. P139

    3  Pages

  9. P137

    3  Pages

  10. P135K

    3  Pages

  11. P135

    3  Pages

  12. P143

    4  Pages

  13. P133

    4  Pages

  14. PDM80-2

    3  Pages

  15. PD82

    4  Pages

  16. PD41

    4  Pages

  17. PD40

    3  Pages

  18. PDM80-1

    4  Pages

  19. PM63

    3  Pages

  20. PM82-4

    4  Pages

  21. PM82-3

    4  Pages

  22. PM82

    3  Pages

  23. PR20

    3  Pages

  24. PR10

    3  Pages

  25. PM40

    4  Pages

  26. P143

    4  Pages

  27. P136

    4  Pages

  28. P132

    5  Pages

  29. P131

    4  Pages

  30. P126

    4  Pages

  31. P121

    5  Pages

  32. P120

    4  Pages

  33. P115

    3  Pages

  34. P21

    3  Pages

  35. P20

    3  Pages

  36. P12

    4  Pages

  37. P10

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.