Datasheet Pressure Transmitter P126PERFORMANCE FEATURESDry capacitive ceramic sensor ■ Adjustable range (Turndown) 5:1 ■ Smallest measuring range: 0...10 mbar ■ Largest measuring range: 0.60 bar ■ Negative pressure measuring range: up to -1 bar ■ High overload capability ■ Compact and rugged design The P126 model is characterized by its on-site adjustment capability. The measuring range can be fine-tuned subsequently and the cable is connected directly to the integrated clamps. Teach-in of filling levels is therefore quick and uncomplicated to perform. The ceramic sensor element is resistant to aggressive and abrasive media. The capacitive measuring principle enables a very accurate and long-term stable measurement even at lowest pressures and high overload resistance. Its housing is made of high-quality stainless steel 1.4404 and is therefore suitable for almost all media. Our modular design concept provides a wide variety of products. Feel free to contact us if you need a customization that is not listed in this datasheet. AREAS OF APPLICATION ■ Aggressive media ■ Level measurement in tanks Noding Messtechnik GmbH • Oldenfelder Bogen 29 • D-22143 Hamburg, Germany • Tel.: 040 / 67 58 51 - 0 Fax: 040 / 67 58 51 - 49 • Internet: www.noeding-messtechnik.de • E-mail: info@noeding-messtechn

 Open the catalog to page 1
P126-2

Measuring range ■ LOAD Supply voltage 9.30 V DC 0,02 A Noding Messtechnik GmbH • Oldenfelder Bogen 29 • D-22143 Hamburg, Germany • Tel.: 040 / 67 58 51 - 0 Fax: 040 / 67 58 51 - 49 • Internet: www.noeding-messtechnik.de • E-mail: [email protected]

 Open the catalog to page 2
P126-3

■ MEASURING RANGES Measuring ranges Ranges Measuring ranges see table 99 Non-standard range (on request) Process connection and material 2 1/2 - 14 NPT, 1.4404 G G1/2 A u. 11,8 mm drill hole, ISO 228-1, 1.4404 9 Others (on request) Sensor seal 1 PM (Viton), standard 5 FFKM (Chemraz / Kalrez) Optionen R Ceramic sensor 99,9%

 Open the catalog to page 3
P126-4

P126 Datasheet Pressure Transmitter DIMENSIONS PROCESS CONNECTION PROCESS CONNECTION 10/2022 A - Modifications reserved without notice Nöding Messtechnik GmbH • Oldenfelder Bogen 29 • D-22143 Hamburg, Germany • Tel.: 040 / 67 58 51 – 0 Fax: 040 / 67 58 51 – 49 • Internet: www.noeding-messtechnik.de • E-mail: info@noeding-me

 Open the catalog to page 4

All Nöding Messtechnik catalogs and technical brochures

  1. TM63

    4  Pages

  2. PTM82

    4  Pages

  3. ERW 72.4

    2  Pages

  4. EMW 63.4

    2  Pages

  5. FM2

    3  Pages

  6. OFS9

    2  Pages

  7. P142

    3  Pages

  8. P139

    3  Pages

  9. P137

    3  Pages

  10. P135K

    3  Pages

  11. P135

    3  Pages

  12. P143

    4  Pages

  13. P133

    4  Pages

  14. PDM80-2

    3  Pages

  15. PD82

    4  Pages

  16. PD41

    4  Pages

  17. PD40

    3  Pages

  18. PDM80-1

    4  Pages

  19. PTM82

    4  Pages

  20. PM63

    3  Pages

  21. PM82-4

    4  Pages

  22. PM82-3

    4  Pages

  23. PM82

    3  Pages

  24. PR20

    3  Pages

  25. PR10

    3  Pages

  26. PM40

    4  Pages

  27. P143

    4  Pages

  28. P136

    4  Pages

  29. P132

    5  Pages

  30. P131

    4  Pages

  31. P121

    5  Pages

  32. P120

    4  Pages

  33. P115

    3  Pages

  34. P21

    3  Pages

  35. P20

    3  Pages

  36. P12

    4  Pages

  37. P10

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.