H2S Concentrations NivuLog H2S and NivuLog H2S Mini Data transmission via GSM or short-range radio Measurement data management via Internet portal D2W Internal measurement data storage for 440.000 measuring cycles Adjustable logging cycle Extremely long battery life up to 5 years through MicroPower® technology Robust, rubber-coated IP66 enclosure with high chemical resistance ATEX certified GPRS DATA LOGGER NivuLog H2S / H2S Mini Compact, portable measurement instrument for data collection of H2S concentration in channel networks www. Specifications are subject to change. H:\\\\nlm0-h2s-db-en.cdr / 10.04.2012 Hydrogen sulfide (H2S) is produced as a result from the degradation of biomass. Far flowing distances, long flowing times as well as saving water at constant pollution loads cause the loads to start decomposition even within the channel. This in turn leads to heavy corrosion of concrete channel constructions and, in combination with water, destroys the channel constructions in the long run. To avoid damaged channels it makes sense to investigate the hydrogen sulfide concentration, which allows to take the appropriate corrective measures. Typical Applications NivuLog H2S Data transmission via GSM + Wastewater treatment plants + Industries NivuLog H2S Mini Data transmission via short-range radio NIVUS GmbH • Im Taele 2 • 75031 Eppingen, Germany • Internet: www.nivus.com Phone: +49 (0)7262 9191-0 • Fax: +49 (0)7262 9191-999 • E-Mail: info@nivus.com + Public Water and sewage systems

Open the catalog to page 1
Data Logger H2S / H2S Mini - 2

GPRS DATA LOGGER H2S Concentrations NivuLog H2S and NivuLog H2S Mini Technical Information Enclosure Dimensions Enclosure Dimensions Measurement range 0 ... 1000 ppm 0.1 ... 0.25 ppm resolution 2 % repeat accuracy Range temperature -10°C ... 40°C Temperature Ambient -10 °C ... 40 °C Storage -20 °C ... 70 °C Relative humidity 15 % ... 90 % r.F Ambient pressure Barometric pressure ±10 % Declaration of conformity - directive Electromagnetic compatibility 2004 / 108 / EG: EN61326 Emission class B Low voltage 2006 / 95 / EG: EN61010 - 1 Lifecycle of H2S sensor 24 months in air Protection IP 66...

Open the catalog to page 2

All NIVUS GmbH catalogs and technical brochures

  1. NivuCam

    2 Pages

  2. OCM F

    4 Pages

  3. NICOS 2.0

    12 Pages

  4. Nivus OCM F

    4 Pages

  5. NivuFlow 750

    12 Pages

  6. AquaBar

    2 Pages

  7. i-Series

    6 Pages

  8. NivuFlow 600

    8 Pages

  9. NivuFlow 650

    12 Pages

  10. Rain Gauge

    2 Pages

  11. OFR Radar

    4 Pages

  12. NivuLog Easy

    2 Pages

  13. PCM F

    2 Pages

  14. NivuScope 2

    4 Pages