NIVELCO LEVEL TRANSMITTERS - GUIDED MICROWAVE - MicroTREK
6Pages

{{requestButtons}}

Catalog excerpts

NIVELCO LEVEL TRANSMITTERS - GUIDED MICROWAVE - MicroTREK - 1

LEVEL TRANSMITTERS

Open the catalog to page 1
NIVELCO LEVEL TRANSMITTERS - GUIDED MICROWAVE - MicroTREK - 2

GENERAL DESCRIPTION The MicroTREK Guided Wave Radar level transmitter is designed for continuous level measuring of conductive or non-conductive liquids, pulps and solids. MicroTREK level gauge operates based on the well-known TDR (Time Domain Reflectometry) principle. Micropulses are sent along a probe guide at the speed of light. As soon as the impulse reaches the surface of the medium, it is reflected back to the electronic module. Level distance is directly proportional to the flight time of the impulse. The reflected signal is dependent on the dielectric constant of the material, the...

Open the catalog to page 2
NIVELCO LEVEL TRANSMITTERS - GUIDED MICROWAVE - MicroTREK - 3

Plastic housing Metal housing Stainless steel housing (High temp. version Measured values Measuring range Probe types Linearity error^ Accuracy Resolution Minimum er of the medium Power supply Digital communication Display Output Medi um temperature Maximum medium pressure Ambient temperature Process connection Ingress protection Electrical connection Electrical protection Housing material Sealing Explosion protection Mass (head unit) ^ Under reference conditions and stabilized temperature Distance, level; calculated values: volume, mass Depends on the probe type and dielectric constant...

Open the catalog to page 3
NIVELCO LEVEL TRANSMITTERS - GUIDED MICROWAVE - MicroTREK - 4

Type HDK, HDL HOY, HOW Denomin. Cable HD A, HOB HOC, HDH Coaxial Max. meas. dist. Min. meas. dist. (Sr = 80 / Sr = 2.4) Min. Sr of the medium Sensing space around the probe Process connection Probe material Probe nominal 0 Mass Separator material® Weight dimensions Weight material 0.24 kg/m (0.16 Ib/ft) PFA, welded on the cable 040 x 80 mm (1.5 x 3 inch) ^ There is no separator below 1.5 m (5 feet) length TECHNICAL DATA OF THE COATED PROBES Max. meas. dist. Min. meas. dist. (er = 80 / Sr = 2.4) Min. Sr of the medium Sensing space around the probe Process connection Max. medium temp. Probe...

Open the catalog to page 4
NIVELCO LEVEL TRANSMITTERS - GUIDED MICROWAVE - MicroTREK - 5

mvELcn INSTALLATION WIRING Display module connector Except the plastic coated and the coax types the probes can be removed from the head unit by the user. s = minimum distance from the internal disturbing objects. Objects that are parallel to probe do not disturb the measurement. Mono Probe s > 300 mm h < d Twin Probe s > 100 mm t = upper dead-zone Coaxial Probe s = 0 mm b = lower dead-zone SETUP, PROGRAMMING with SAP-300 display unit With the help of the SAP-300 plug-in display a simplified programming can be accomplished which covers most of the applications. The basic parameters of...

Open the catalog to page 5
NIVELCO LEVEL TRANSMITTERS - GUIDED MICROWAVE - MicroTREK - 6

ORDER CODES (not all combinations available) MicroTREK Guided Wave Radar level transmitters Transmitter Transmitter + display High temperature transmitter High temperature transmitter + display Aluminium Plastic ^ The order code of an Ex version should end in "EX' ® Ex version not available (3) Segmented probe version should be given in the text of the order 4 Only for HT, HB and probes without coating 4 - 20 mA + HART® 4 - 20 mA + HART® / Ex tD<4) 4 - 20 mA + HART® / Ex iaD 4 - 20 mA + HART® / Ex ia Plug-in graphical display module NIVELCO reserves the right to change technical data...

Open the catalog to page 6

All NIVELCO Process Control Co. catalogs and technical brochures

Archived catalogs