NIVELCO LEVEL SWITCHES - VIBRATION ROD - NIVOCONT R
6Pages

{{requestButtons}}

Catalog excerpts

NIVELCO LEVEL SWITCHES - VIBRATION ROD - NIVOCONT R - 1

LEVEL SWITCHES VIBRATING ROD LEVEL SWITCHES FOR SOLIDS

Open the catalog to page 1
NIVELCO LEVEL SWITCHES - VIBRATION ROD - NIVOCONT R - 2

GENERAL DESCRIPTION AIU The NIVOCONT R series of vibrating rod level switches are robust instruments designed for low and high level indication of granules and powders with a minimum of 0.05 kg/dm3 density. Mounted on tanks, silos or hopper bins it can control filling / emptying, or give fail-safe alarm signals. The highly polished version is recommended to use for abrasive mediums. The operation principle is based on that the electronic circuit excites a vibration in the rod probe. When the medium reaches and covers the rod, its vibration stops, when the medium leaves the rod it returns to...

Open the catalog to page 2
NIVELCO LEVEL SWITCHES - VIBRATION ROD - NIVOCONT R - 3

(2) Only with metal housing ^ Need of IEC is to be specified with order Temperature diagram Temperature limit values for Ex versions Temperature data Ambient temperature (Ta) versus Medium temperature (TM) To operate the level switch with the maximum values of the related temperature data the applied cable should permanently withstand up to +90 °C (+194 °F) temperature. Medium temperature for max. ] hour: +95 °

Open the catalog to page 3
NIVELCO LEVEL SWITCHES - VIBRATION ROD - NIVOCONT R - 4

OPERATION rkh5s19a0604b Power supply Fail-Safe kapcsolo Status LED Low Energised De-energised Energised ON NIVELCO reserves the right to change technical data without notice! Specifications in metric & US units! ORDER CODES (not all code versions are available) NIVOCONT R vibrating rod level switches Insertion length Version Code Power supply / Output / Ex Code ^ The order code of an Ex version should end in „Ex" <2) Only for Standard and Pipe extended versions <3) Not available in Ex version NIVELCO PROCESS CONTROL CO. H-1043 Budapest, Dugonics u. 11. Tel.: (36-1) 889-0100 ■ Fax: (36-1)...

Open the catalog to page 4
NIVELCO LEVEL SWITCHES - VIBRATION ROD - NIVOCONT R - 5

WIRING Relay output Status LED Mode switches Power supply Relay output Electronic output Status LED Power supply MODE SWITCHES Mode switches Output overload indication Electronic output High Fail-safe Fail-safe alarm is indicated with de-energised relay or open state of the solid state output.

Open the catalog to page 5
NIVELCO LEVEL SWITCHES - VIBRATION ROD - NIVOCONT R - 6

INSTALLATION The probe should be protected against strong material inflow by appropriate selection of the mounting position or by using an overhead protective shield. When the instrument is mounted on the side of the tank, coning or arching of the material should be taken into consideration. In dusty mediums the inclination of the side mounted probe should be greater than the angle of repose to ensure self cleaning and avoid deposition of material on the vibration rod switches. Avoid mounting the unit close to the filling entry or near to medium accumulation. Distance between the probe and...

Open the catalog to page 6

All NIVELCO Process Control Co. catalogs and technical brochures

Archived catalogs