Catalog excerpts
Analytical instruments LIQUID ANALYTICAL TRANSMITTERS
Open the catalog to page 1Graphic display 4-20 mA, HART, relay output IP67 / IP68 protection Ex version AnaCONT COMPACT pH, ORP and DO TRANSMITTERSMAIN FEATURES Compact and integrated versions Separated versions up to 10m Measurement range: pH: 0-14, ORP: ±1000 mV, DO: 0-20 ppm Wide probe selection suitable for most applications Temperature compensation The AnaCONT liquid analytical transmitters are designed to measure pH, redox potential, or dissolved oxygen values of liquids and aqueous solutions. pH measurement: Continuous measurement of acidity (pH<7) and of basicity (pH>7) in liquids can be performed by the...
Open the catalog to page 2General data Temperature measuring (semiconductive sensor) Liquid potential (complementary) electrode 0.01pH (internal resolution 0.004 pH) 1 mV (internal resolution 0.8 mV) ±0.004 pH ±0.4 mV 0.1% of the measured value ±1 digit ±0.01% / °C 0 - 20 ppm v. 0 - 10 ppm 20% 0.01 ppm (internal resolution 0.005 ppm) ±0.05 ppm 0.5% of the measured value ±1 digit ±0.01% / °C 300 msec, on display: 1 sec Range: -50.130 °C, Accuracy: ±0.5 °C, Resolution: 0.1 °C Housing of the temperature sensor: stainless steel (1.4571), connection: SN6 Electrode input Power supply / Power consumption Analogue Output...
Open the catalog to page 3C O N F I G U R AT I O N S The constructions of the sensors on the compact and integrated versions are identical, so all accessories are applicable for both types. The applications of the special accessories make the optimal installation of the transmitters into the technologic process easier. By using extension pipes or extension cables the separated versions allow the mounting of the electronics and the sensor part at any distance from each other. SEPARATED TRANSMITTER Signal processing COMPACT TRANSMITTER Integrated transmitter Probe housing +cableextension Suspended probe housing +cable...
Open the catalog to page 4ORDER CODES (probes, solutions) Wide range of measurement probes are available to order for continuous and reliable operation. The originally included sensor can be replaced when case its lifespan is over. Sensor replacement can be necessary also if the used technology changes significantly. The offered solutions are recommended for required periodic calibrations, and storing or cleaning of the probes. Order code Order code Buffer solution pH4 / 50 ml Buffer solution pH4 / 250 ml Buffer solution pH4 / 1 l Buffer solution pH7 / 50 ml Buffer solution pH7 / 250 ml Buffer solution pH7 / 1 l...
Open the catalog to page 5ORDER CODES (not all combinations available) AnaCONT liquid analytical transmitters AnaCONT Type Code Function Code Transmitter + display Integrated P ACCESSORIES Extension units LA- 4 - 20 mA 4 - 20 mA / HART 4 - 20 mA / Ex 4 - 20 mA / HART / Ex 4 - 20 mA / Relay 4 - 20 mA / HART / Relay Code Material Code H Code Extension length4 Code 1 All cables of the required length and terminals are included 2 Terminals are included in the cable set 3 Cables and terminals are not included! LAK- for the pipe extended version for separate mounting has to be ordered separately (L + the distance between...
Open the catalog to page 6All NIVELCO Process Control Co. catalogs and technical brochures
-
NIVELCO Product Catalogue 2020/2
242 Pages
-
NIVELCO Product Overview 2020
14 Pages
-
NIVELCO Application handbook 2018
122 Pages
-
NIVELCO Magazine 2019/1
36 Pages
-
NIVELCO Magazine 2018/2
40 Pages
-
NIVELCO Magazine 2018/1
36 Pages
-
NIVELCO Magazine 2017/1
36 Pages
-
NIVELCO Magazine 2016/2
36 Pages
Archived catalogs
-
NIVELCO Magazine 2016/1
36 Pages
-
NIVELCO Magazine 2015/2
36 Pages
-
NIVELCO Magazine 2015/1
36 Pages
-
NIVELCO Magazine 2014/2
36 Pages
-
NIVELCO Magazine 2014/1
36 Pages
-
NIVELCO Magazine 2013/2
36 Pages
-
NIVELCO Magazine 2013/1
36 Pages
-
NIVELCO Magazine 2012/2
36 Pages
-
NIVELCO Magazine 2012/1
36 Pages
-
NIVELCO Magazine 2011/2
36 Pages
-
NIVELCO Magazine 2011/1
36 Pages
-
NIVELCO Magazine 2010/2
36 Pages