Overview
The Venus 301 is a high-quality TOC and methane-NMHC analyzer designed for air quality monitoring. It features advanced analytics, a long instrumental lifetime, and a user-friendly interface.

PC Embedded Technology
The analyzer integrates a PC running on Windows®, providing software supervision for all parameters and operations. It records analyses and stores alarms/faults locally, with data downloadable in .csv format via USB or Ethernet.

Sampling Loop Analysis Technology
This technology uses loop sampling to withdraw and push known sample volumes into the detector, offering stable and accurate results with reduced maintenance compared to continuous sample flow systems.

Methane - NMHC Analysis
The instrument performs analysis using packed columns with back flush technology, ensuring reliability and stability without the need for bulky accessories.

Comparison with Traditional FID Analyzers
Traditional FID analyzers require frequent calibration and maintenance due to capillary sampling clogging. The Venus 301 reduces these costs with its loop sampling system and enhanced diagnostics via PC technology.

Requirements
The system requires hydrogen (4.5 grade pure, 3 bar) and air (3 bar) from the network, with a consumption of 50 ml/min. It also requires a power supply of 230V or 115V.

Calibration and Maintenance
Maintenance and calibration frequencies are minimized, with a service visit recommended once a year and a calibration check every 6 months, guided by software.

Aftersales Support
The service department offers email, remote, and phone support, with over 500 interventions annually and a global service network. Interventions are organized within 5 working days in Europe and 10 worldwide.
See more

Catalog excerpts

VOC met-NMHC FID VENUS 301-1

TOC and methane-NMHC analyzer for air qualityVenus 301 • High quality construction. • Advanced analytics. • Extremely long average instrumental lifetime. • Simple and clear user interface.

 Open the catalog to page 1
VOC met-NMHC FID VENUS 301-2

We integrated a PC, working on Windows® operating system able to ensure • Software supervision on all parameter. • Analysis recording and alarms/faults storage in local memory. • Downloadable analysis in .csv compatible files. ARIA FID(bar) SERVO PRESS.(bar) PORTATA CAMPIONE (ml/min) ANALISI SIHGOLA TEST HARDWARE

 Open the catalog to page 2
VOC met-NMHC FID VENUS 301-3

Sampling loop analysis technology A known volume of the sample stream is repeatedly withdrawn and pushed into the detector using loop sampling. The VOC concentration is proportional to the area under the peak. In this way, we obtain much more stable and accurate results with less maintenance, despite standard systems, which use continuous sample flow capillaries that can become clogged.

 Open the catalog to page 3
VOC met-NMHC FID VENUS 301-4

Methane - NMHC analysis Performed via packed columns, directly integrated into the instrument. We don't need bulky and/or expensive accessories. Chromatographic separation with back flush technology ensures extraordinary reliability and stability on stationary analyzers.

 Open the catalog to page 4
VOC met-NMHC FID VENUS 301-5

COMPARISON WITH SIMILAR EQUIPMENTS TRADITIONAL FID ANALYZER VENUS 301 FID  Frequent calibration and maintenance.  Reduced calibration and maintenance costs due to Span& zero drifts costs thanks to our loop sampling system (capillary sampling clogging effect). technology.  Limited diagnostics and interface.  Developed diagnostics and interface, thanks to our PC embedded techno

 Open the catalog to page 5
VOC met-NMHC FID VENUS 301-6

REQUIREMENTS Our FID systems requires hydrogen and compressed air Air from your network (3 bar) Hydrogen 4,5 grade pure (3 bar) 40 Liters gas cylinder or optional H2 generator CONSUMPTION = 50 ml/min. Nira filtering system CONSUMPTION = 1 m³/hour

 Open the catalog to page 6
VOC met-NMHC FID VENUS 301-7

CALIBRATION AND MAINTENANCE We worked hard to minimize maintenance and calibration frequencies, obtaining record results. Every 6 months: Calibration check, the procedure is guided from the software and takes just few minutes using a preinstalled standard gas cylinder. Once a year, ask for a service visit from our staff.

 Open the catalog to page 7
VOC met-NMHC FID VENUS 301-8

COMPETENCE IN AFTERSALES Our service department work worldwide every day, on 6 different kind of Nira instruments:  E-mail, remote and phone service.  More than 500 interventions performed per year.  More than 1000 instruments serviced worldwide.  Less than 5 working days to organize an intervention within Europe, 10 world

 Open the catalog to page 8