1. Catalogs
  2. Nira Srl
  3. Sagittarius 5000 IR LEL-LFL presentation

Sagittarius 5000 IR LEL-LFL presentation

Sagittarius 5000 IR LEL-LFL presentation

Sagittarius 5000 IR LEL-LFL presentation

Product catalog summary
Overview: The Sagittarius (IR) is a monitoring system designed for the lower exposure limit (LEL) of flammable gases, offering fast response times, high reliability, and low management costs. It is EN 1539 certified and suitable for single or multipoint monitoring.
Infrared Detector Principle: The system uses an infrared detector where the sample gas passes through an analytical cell. The infrared light emitted is absorbed by the gas, and the decrease in light intensity is proportional to the gas concentration. This method is cost-effective for simple solvent mixtures in low-temperature applications.
Operation: The system continuously samples gas from an oven or duct, measures it, and returns it safely. Data is transmitted to a control unit that manages concentration thresholds and system status. The control unit integrates with the plant's PLC logic for immediate response.
LEL Monitoring Systems Comparison:
  • Response Time: Traditional systems have a 5-second response time, while Sagittarius offers a 1.4-second response.
  • Calibration & Maintenance: Traditional systems require frequent calibration, whereas Sagittarius has auto-zero and auto-span drift compensation, eliminating the need for maintenance.
  • Target Calibration: Traditional systems calibrate on a single solvent, while Sagittarius optimizes calibration for specific solvent mixtures.
  • Detector Lifespan: Traditional detectors have a 2-year lifespan, while Sagittarius offers a 5-year guarantee.
  • Certifications & Standards: Sagittarius is certified for EN 1539:2015 and Atex for zone 1, PL "D" approval.
System Requirements:
  • Compressed Air: 5 bar from the network, consumption of 1m³/hour per line.
  • Power Supply: 230V or 115V.
After-Sales Expertise: The service department offers email, remote, and phone support, with over 500 interventions per year and 1000+ analyzers worldwide. Response times are under 5 working days in Europe and 10 worldwide.
See more

Catalog excerpts

Sagittarius 5000 IR LEL-LFL presentation-1

FOR LOWER EXPLOSURE LIMIT MONITORING OF FLAMMABLE GASES • Fast response time (T90 in 1,4 sec.) • High reliability • Single or multipoint monitoring

 Open the catalog to page 1
Sagittarius 5000 IR LEL-LFL presentation-2

The sample gas stream passes through an analytical cell (optical path). The infrared light emitted by the source is absorbed by the sample gas in the cell and captured by a receiver. The decrease in intensity between the emitted and captured light is proportional to the concentration of the solvent. Signal detector sourrp'W' Beamsplitter GAS FLOW Compensation detector Flameproof Chamber The infrared system is the cost-effective solution for simple solvent mixtures in low temperature applications.

 Open the catalog to page 2
Sagittarius 5000 IR LEL-LFL presentation-3

HOW IT WORKS The sample is continuously drawn from the oven or duct, routed through the analytical unit for measurement, and safely returned nearby the same sampling point. Concurrently, data is transmitted to the control unit, which automatically manages concentration thresholds and triggers system status contacts whenever necessary. Integration: The control unit seamlessly interlocks with the plant's PLC logic, ensuring immediate and reliable response.

 Open the catalog to page 3
Sagittarius 5000 IR LEL-LFL presentation-4

LEL MONITORING SYSTEMS COMPARISON Features / Norms Response Time Response time in 5 seconds. Response time in 1,4 seconds. Calibration & Maintenance Expensive and frequent calibration/maintenance required due to Span and zero drifts. No calibration/maintenance required thanks to auto-zero and auto-span drifts compensation. Target Calibration Calibration on one single solvent or component only. Optimized calibration on the specific solvent mixture provided by the end user. Detector Lifespan Short life detector, 2 years guarantee. Long life detector, 5 years guarantee. Certifications & Standards...

 Open the catalog to page 4
Sagittarius 5000 IR LEL-LFL presentation-5

SYSTEM REQUIREMENTS POWER SUPPLY from your network (5 bar) CONSUMPTION = 1m³/hour each line

 Open the catalog to page 5
Sagittarius 5000 IR LEL-LFL presentation-6

E-mail, remote service and phone service. Interventions performed per Analyzers followed all over the Response time in working days Response time in working days year world in Europe worldwide Our service department works all over the world every day, on 6 different types of Nira instruments.

 Open the catalog to page 6
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.