FOR LOWER EXPLOSURE LIMIT MONITORING OF FLAMMABLE GASES • Fast response time (T90 in 1,4 sec.) • High reliability • Single or multipoint monitoring
Open the catalog to page 1The sample gas stream passes through an analytical cell (optical path). The infrared light emitted by the source is absorbed by the sample gas in the cell and captured by a receiver. The decrease in intensity between the emitted and captured light is proportional to the concentration of the solvent. Signal detector sourrp'W' Beamsplitter GAS FLOW Compensation detector Flameproof Chamber The infrared system is the cost-effective solution for simple solvent mixtures in low temperature applications.
Open the catalog to page 2HOW IT WORKS The sample is continuously drawn from the oven or duct, routed through the analytical unit for measurement, and safely returned nearby the same sampling point. Concurrently, data is transmitted to the control unit, which automatically manages concentration thresholds and triggers system status contacts whenever necessary. Integration: The control unit seamlessly interlocks with the plant's PLC logic, ensuring immediate and reliable response.
Open the catalog to page 3LEL MONITORING SYSTEMS COMPARISON Features / Norms Response Time Response time in 5 seconds. Response time in 1,4 seconds. Calibration & Maintenance Expensive and frequent calibration/maintenance required due to Span and zero drifts. No calibration/maintenance required thanks to auto-zero and auto-span drifts compensation. Target Calibration Calibration on one single solvent or component only. Optimized calibration on the specific solvent mixture provided by the end user. Detector Lifespan Short life detector, 2 years guarantee. Long life detector, 5 years guarantee. Certifications & Standards...
Open the catalog to page 4SYSTEM REQUIREMENTS POWER SUPPLY from your network (5 bar) CONSUMPTION = 1m³/hour each line
Open the catalog to page 5E-mail, remote service and phone service. Interventions performed per Analyzers followed all over the Response time in working days Response time in working days year world in Europe worldwide Our service department works all over the world every day, on 6 different types of Nira instruments.