FOR MONITORING THE LOWER EXPLOSION LIMIT IN FLAMMABLE GASES • T90 response time in less than 4 seconds (including sampling). • High reliability • Low investment costs thanks to a multi-point layout. • Possibility of heating the analysis and the sample up to 180°C. • Compact wall, rack, outdoor or ATEX area mounting.
Open the catalog to page 1PRINCIPLE OF FID DETECTOR FID: Flame Ionization Detector Through the combustion of clean air, hydrogen and sample gases, the FID detects hydrocarbon ions that induce a current. This current is directly proportional to the organic concentration in the sample gas. The FID is considered the most accurate and reliable detector on the market for organic compounds. It is suitable for any type of application, including those for high-temperature samples.
Open the catalog to page 2HOW IT WORKS The sample is continuously sucked from the sampling probe and routed through the analyzer for measurement. If the set concentration limit is exceeded, the system status contacts are activated. Safety integration: The analyzer interfaces with the plant's PLC logic via free contacts (NC), ensuring an immediate and reliable response.
Open the catalog to page 3MULTIPLE LAYOUTS AVAILABLE Compact, wall mounted, single or multi-line (max.2) ATEX rack, with H2 leak sensor and air conditioner, single or multi-line (max.2) Rack, with H2 leak sensor and air conditioner, single or multi-line (max.10)
Open the catalog to page 4COMPARISON OF FLAME LEL MONITORING SYSTEMS Traditional flame detector Frequent because of large Span/zero drifts in time. Reduced, thanks to sampling loop technology and multi-point layouts Stability Readings Unstable with interferers (e.g. water or oxygen content variations) Very stable and optimized for common interferents Conforms to EN 60079-29-1 ed EN 1539 (regulations for ovens)
Open the catalog to page 5• Consumption = 4 m3/hour (more cunsumption if more than 4 lines are applied) Power Supply
Open the catalog to page 6CALIBRATION AND MAINTENANCE Our analyzer has been designed to minimize our maintenance interventions Request a maintenance visit from our staff. Calibration verification, the procedure is software-driven and takes only a few minutes using a standard gas cylinder.
Open the catalog to page 7E-mail, remote service and phone service. Interventions performed per Analyzers followed all over the Response time in working days Response time in working days year world in Europe worldwide Our service department works all over the world every day, on 6 different types of Nira instruments.