Sagittarius 2000 ENG P

Sagittarius 2000 ENG P
1 / 10 PagesView full catalog

Sagittarius 2000 ENG P

Product catalog summary
Specifications:
The Sagittarius FID is designed for lower exposure limit monitoring of flammable gases, featuring a fast response time (T90 in less than 2 seconds), high reliability, and stability over time. It is Ex Proof and EN 1539 certified, with low management costs and capabilities for single/multipoint monitoring and heating up to 200°C. It can be mounted on walls or racks and is suitable for outdoor installation.
Layout:
The analyzer is housed in an electro-pneumatic cabinet suitable for both indoor and outdoor installations. Sample collection lines draw gas from sampling points, and the system includes a hydrogen leak sensor for safety.
Working Principle:
The FID (Flame Ionization Detector) operates by combusting clean air, hydrogen, and sample gas to detect hydrocarbon ions, which induce a current proportional to the organic chemical concentration. This method is precise and reliable, suitable for high-temperature samples, and uses a loop sampling technique for stable and repeatable results.
Sampling Loop Analysis Technology:
An industrial PC is integrated for software supervision, ensuring high stability and monitoring of all parameters. It features a user-friendly interface and supports USB, Ethernet, Modbus, and 4-20mA outputs.
Ex-Proof and Norms:
The Sagittarius 2000 FID offers reduced calibration and maintenance costs, enhanced readings with interfering compounds, and high accuracy (±0.5% LEL). It complies with EN 60079-29-1 and EN 1539 standards.
Requirements:
The system requires hydrogen (4.5 grade pure, 3 bar) and air (5 bar), with a consumption of 50 ml/min. It also requires a power supply of 230V or 115V.
Calibration and Maintenance:
Maintenance and calibration frequencies are minimized, with a recommended service visit once a year and a calibration check every 6 months, guided by software.
Aftersales Competence:
The service department offers email, remote, and phone support, with over 500 interventions per year and more than 1000 instruments serviced worldwide. Interventions are organized within 5 working days in Europe and 10 worldwide.
See more

Catalog excerpts

Sagittarius 2000 ENG P-1

SAGITTARIUS (FID) FOR LOWER EXPLOSURE LIMIT MONITORING OF FLAMMABLE GASES Fast response time (T90 in less than 2 seconds). High reliability and stability in time. Ex Proof (Detector) and EN 1539 certifications. Low management costs. Single/multipoint monitoring, heating up to 200°C. Wall or rack mounting and outdoor ins

 Open the catalog to page 1
Sagittarius 2000 ENG P-2

LAYOUT The analyzer is assembled in an electro-pneumatic cabinet, suitable for indoor or outdoor installation. From the roof of the cabinet, the sample collection lines draw the gas from the sampling points. Our FID detector is Ex Proof certified, and a hydrogen leak sensor guarantees total safety of the system.

 Open the catalog to page 2
Sagittarius 2000 ENG P-3

WORKING PRINCIPLE F.I.D., flame ionization detector. Through the combustion between clean air, hydrogen and the sample gas, the FID can detect hydrocarbon’s ions that induce a current. This current is directly proportional to the organic chemical concentration inside the sample gas. The FID is considered the most precise and reliable detector on the market, fits any kind of application even for high temperature samples.

 Open the catalog to page 3
Sagittarius 2000 ENG P-4

SAMPLING LOOP ANALYSIS TECHNOLOGY Our FID analyser is equipped with the best sampling technique. A known volume of sample is repeatedly aspirated, drawn (through a loop), and pushed into the detector, resulting in much more stable, accurate and repeatable results than all standard continuous sample flow technologies. The small volume used keeps analyser clean and reduces maintenance/calibration frequencies.

 Open the catalog to page 4
Sagittarius 2000 ENG P-5

We integrated a robust industrial PC, advantages: • Software supervision on all parameter • High software stability, externally monitored by a watchdog system • Software supervision on every operation step • Analysis trend and alarms/faults storage in the local memory • Simple and clear user interface • USB , Ethernet, Modbus and 4-20mA outputs

 Open the catalog to page 5
Sagittarius 2000 ENG P-7

LEL MONITORING SYSTEMS COMPARISON Traditional Flame detector • Frequent calibration and maintenance costs due to huge Span and zero drifts • Unstable readings with interfering compounds like water or with low Oxygen content in the sample • Only complies with EN 60079-29-1 • Reduced calibration and maintenance costs due to our loop sampling system • Enhanced reading even with interfering compounds like water or with low oxygen content in the sample. • High accuracy in readings (±0,5% LEL) • Complies with EN 60079-29-1 and EN 1539 (oven and furnaces norm)

 Open the catalog to page 7
Sagittarius 2000 ENG P-8

REQUIREMENTS Our FID systems requires hydrogen and compressed air Hydrogen 4,5 grade pure (3 bar) Air from your network (5 bar) 40 Liters gas cylinder or optional H2 generator Nira filtering system

 Open the catalog to page 8
Sagittarius 2000 ENG P-9

CALIBRATION AND MAINTENANCE We worked hard to minimize maintenance and calibration frequencies, obtaining record results. Every 6 months: Calibration check, the procedure is guided from the software and takes just few minutes using a preinstalled standard gas cylinder. Once a year, ask for a service visit from our staff.

 Open the catalog to page 9
Sagittarius 2000 ENG P-10

COMPETENCE IN AFTERSALES Our service department work worldwide every day, on 6 different kind of Nira instruments:  E-mail, remote and phone service.  More than 500 interventions performed per year.  More than 1000 instruments serviced worldwide.  Less than 5 working days to organize an intervention within Europe, 10 world

 Open the catalog to page 10