FAST RESIDUAL SOLVENT ANALYSIS NEPTUNE 803 Tabletop model • Quickly analyse residual solvents from single or complex films (5 to 10 minutes). • Usable by unskilled personnel. • Check the solvents, inks and adhesives composition. • EN 13628 and ASTM 1884 compliant.
Open the catalog to page 1TURN RESIDUAL SOLVENT ANALYSIS INTO NEPTUNE 803 Skilled technician required Usable by press Neptune803 operators Response time 7 min. Response time in 45 min. The speed of the Neptune analyser allows production to correct for high concentrations of residual solvent, starting with the first roll produced.
Open the catalog to page 2COMPARISON WITH STANDARD GCs TRADITIONAL LAB GC Response time from 45 to 50 min. Slow and complex sampling. Need frequent span checks. Complex software and report reading. For skilled personnel only. Works in clean and temperaturecontrolled environment only. No fault alarm recording. NEPTUNE GC Response time from 7 to 14 min. Quick and easy sampling. Stability up to 6 months. Guided software and easy reports. Anyone can use it. Works in harsh environment (made for production areas).
Open the catalog to page 3HOW TO USE IT? Neptune 803 quickly extract and measure residual solvents from single or multilayer films automatically Simply cut a known film sample and insert it into the headspace. Neptune will print and create a .pdf file report with the results, directly on your corporate network within 7 minutes.
Open the catalog to page 4SIMPLE & COMPLETE REPORTS Information Date and time Single solvent Concentration Analysis conditions TOTAL RESIDUAL SOLVENT in mg/m²
Open the catalog to page 5COMPARABLE RESULTS TO THE MAIN EUROPEAN AND US STANDARDS
Open the catalog to page 6REQUIREMENTS Our FID systems requires hydrogen and compressed air Air from your network (3 bar) Hydrogen 4,5 grade pure (3 bar) 40 Liters gas cylinder or optional H2 generator CONSUMPTION = 50 ml/min. Nira filtering system CONSUMPTION = 1 m³/hour
Open the catalog to page 7CALIBRATION AND MAINTENANCE We worked hard to minimize maintenance and calibration frequencies, obtaining record results. Every 6 months: Calibration check, the procedure is guided from the software and takes just few minutes using a single injection of a customized standard mixture. Once a year, ask for a service visit from our staff.
Open the catalog to page 8COMPETENCE IN AFTERSALES Our service department work worldwide every day, on 6 different kind of Nira instruments: E-mail, remote and phone service. More than 500 interventions performed per year. More than 1000 instruments serviced worldwide. Less than 5 working days to organize an intervention within Europe, 10 world