Emission VOC FID Aries-Mercury

Emission VOC FID Aries-Mercury

Emission VOC FID Aries-Mercury

Product catalog summary
Overview
ARIES 1003 and MERCURY 903 are advanced solutions for monitoring Volatile Organic Compounds (VOCs) emissions, offering high accuracy, simplicity, and analytical stability. These instruments are equipped with FID detectors and automatic pressure regulators controlled by software, ensuring reliable performance.

Key Features
  • Integrated PC and Software: Both models include an industrial PC with Windows® OS, featuring a touch screen interface. The PC functions as a data logger, storing analysis results in Excel® compatible formats and detecting faults.
  • Sampling Technology: Utilizes a sampling valve with no mechanical moving parts, enhancing analytical stability and reducing maintenance needs.
  • Methane Analysis: Conducted via a catalytic converter or packed column, compliant with European standard EN 25140:2010.

System Variants
  • ARIES 1003 (Stationary): Features an ejector system requiring no maintenance and includes a vacuum sensor for leak detection.
  • MERCURY 903 (Portable): Equipped with a heated suction pump to prevent condensation and a vacuum sensor for leak detection.

Accessories
  • ARIES: Rack assembly with IP55 protection, customizable data logger, heated sampling line, VOC sampling line, and pure air generator.
  • MERCURY: Heated sampling line, pure air generator, and metal hydride cylinder for hydrogen gas supply.

Technical Specifications
  • Operating Temperature: ARIES: -20 to +50°C, MERCURY: +5 to +40°C
  • Oven Temperature: 0-180°C for ARIES, 50-180°C for MERCURY
  • Detector Type: FID for both models
  • Maintenance Interval: 6 months
  • Response Time: 12 seconds
  • VOC and Methane Ranges: 0-100, 1000, 10000 mgC/m³ for VOCs; 0-100, 1000 mg/m³ for Methane
  • Detection Limit: 0.1 mg/m³
  • Accuracy and Linearity: <0.1% f.s. accuracy, <2.0% f.s. linearity
  • Data Availability: 1000 days FIFO
  • Power Supply: 230Vdc or 110Vdc

Compliance
Both analyzers comply with EN 12619, EN 15267-3/4 for VOC analysis, EN 25140 for methane analysis, and EN 14181 QAL1 standards.
See more

Catalog excerpts

Emission VOC FID Aries-Mercury-1

New Instruments and Research for Analysis 0ERMJ EMISSION ANRLVZERS TO MONITOR THE TOTAL GASEOUS ORGANIC CARBON ARIES 1003 (fixed version) and MERCURY 903 (portable version), are the right solution for the VOCs emission monitoring, in term of accuracy, simplicity and analytical stability. > FID detector and automatic pressure regulators driven by software > Industrial integrated PC equipped with Windows® OS > Touch screen display interface > Methane analytical kit with catalyst INTEGRATED PC EMBEDDED TECHNOLOGY The industrial PC housed in the analyzer, in addition to monitor and control the Detector, the thermoregulation and every operation, has the task of Data logger and saves the analysis in an Excel® compatible format file. The Windows Embedded® operating system with his advanced software, guides and supports you at all times. Every fault is detected and stored. We use sampling valve with no mechanical moving parts, able to guarantee two exclusives advantages despite the classic calibrated capillaries tachnology. • More analytical stability • Less maintenance frequency Performed via a catalytic converter or packed column directly housed into the instrument. Doesn't need any bulky and/or expensive accessory. The converter is automatically excluded in the event of an exceeding organic concentration may overheat it.The catalyst analysis is carried out in accordance with European standard EN 25140:2010.

 Open the catalog to page 1
Emission VOC FID Aries-Mercury-2

NORMATIVE REFERENCES SAMPLE SUCTION SYSTEMS & VACUUM SENSORS > Mercury (portable system) use a head heated suction pump to prevent any kind of condensation in the sample. > Aries (stationary system) use an ejector system (no maintenance required). Both analyzers are equipped with a vacuum sensor which generate an alarm if any leakage or filter clogging condition occur. These two analyzers are compliant with the following regulations: > EN 12619 and EN 15267-3/4 - construction and performance criteria for the analysis of VOCs > EN 25140 - construction and performance criteria for the analysis...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.