ARIES1003, TOC AND METHANE - NMHC ANALYZER FOR EMISSIONS High quality construction High stability of analyses. Extremely long average instrumental
Open the catalog to page 1LAYOUT The analyser is assembled in an electro-pneumatic cabinet, suitable for indoor or outdoor installation. From the roof of the cabinet, the sample collection lines draw the gas from the sampling points. Our FID detector is Ex Proof certified, a hydrogen leak sensor guarantees total safety of the rack.
Open the catalog to page 2SAMPLING LOOP ANALYSIS TECHNOLOGY Our FID analyser is equipped with the best sampling technique. A known volume of sample is repeatedly aspirated, drawn (through a loop), and pushed into the detector, resulting in much more stable, accurate and repeatable results than all standard continuous sample flow technologies. The small volume used keeps analyser clean and reduces maintenance/calibration frequencies.
Open the catalog to page 3METHANE - NMHC ANALYSIS OPTION Performed via packed columns, directly integrated into the instrument. We don’t need any bulky and/or expensive accessories. Chromatographic separation with back flush technology ensure extraordinary reliability and stability on fixed analyzers.
Open the catalog to page 4PC EMBEDDED TECHNOLOGY Integrated a PC, working on Windows® operating system able to ensure: • Software supervision on all parameter. • Downloadable analysis in .csv compatible files. • Simple and clear user interface. • Downloads via USB or Ethernet ports.
Open the catalog to page 5ENHANCED FEATURES FOR TOC DETECTION Comparison Traditional FID analyzer Expensive costs due to a single point Cheaper costs due to the multipoint monitoring capacity monitoring capacity (inlet monitoring) Frequent calibration and maintenance Reduced calibration and maintenance costs due to Span& zero drifts costs thanks to our loop sampling system (capillary sampling) technology. Limited diagnostics and interface Developed diagnostics and interface thanks to our PC embedded t
Open the catalog to page 6REQUIREMENTS Our FID systems requires hydrogen and compressed air Hydrogen 4,5 grade pure (3 bar) Air from your network (5 bar) 40 Liters gas cylinder or optional H2 generator Nira filtering system
Open the catalog to page 7CALIBRATION AND MAINTENANCE We worked hard to minimize maintenance and calibration frequencies, obtaining record results. Every 6 months: Calibration check, the procedure is guided from the software and takes just few minutes using a preinstalled standard gas cylinder. Once a year, ask for a service visit from our staff.
Open the catalog to page 8• E-mail, remote and phone service. • More than 500 interventions performed per year. • More than 1000 instruments serviced worldwide. • Less than 5 working days to organize an intervention within Europe, 10 worldwide.