ARIES1003, TOC AND METHANE - NMHC ANALYZER FOR EMISSIONS High quality construction High stability of analyses. Extremely long average instrumental Comply with: EN 12619 EN 15267-3 Certified
Open the catalog to page 1PC EMBEDDED TECHNOLOGY Integrated a PC, working on Windows® operating system able to ensure: Software supervision on all parameter. Software supervision on every operation step. Analysis recording and alarms/faults storage in local memory. Downloadable analysis in .csv compatible files. Simple and clear user interface. Downloads via USB or Ether
Open the catalog to page 2SAMPLING LOOP ANALYSIS TECHNOLOGY A known volume of the sample flow is repeatedly picked up and pushed into the detector using a loop sampling. In this way, we get much more stable and accurate results with lower maintenance, despite standard systems, which use continuous sample flow capillaries that may clog.
Open the catalog to page 3METHANE - NMHC ANALYSIS OPTION Performed via packed columns, directly integrated into the instrument. We don’t need any bulky and/or expensive accessories. Chromatographic separation with back flush technology ensure extraordinary reliability and stability on fixed analyzers.
Open the catalog to page 4ENHANCED FEATURES FOR TOC DETECTION Expensive costs due to a single point Cheaper costs due to the multipoint monitoring capacity monitoring capacity (inlet monitoring) Frequent calibration and maintenance Reduced calibration and maintenance costs due to Span& zero drifts costs thanks to our loop sampling system (capillary sampling) technology. Limited diagnostics and interface Developed diagnostics and interface thanks to our PC embedded t
Open the catalog to page 5REQUIREMENTS Our FID systems requires hydrogen and compressed air Hydrogen 4,5 grade pure (3 bar) Air from your network (5 bar) 40 Liters gas cylinder or optional H2 generator Nira filtering system
Open the catalog to page 6CALIBRATION AND MAINTENANCE We worked hard to minimize maintenance and calibration frequencies, obtaining record results. Every 6 months: Calibration check, the procedure is guided from the software and takes just few minutes using a preinstalled standard gas cylinder. Once a year, ask for a service visit from our staff.
Open the catalog to page 7COMPETENCE IN AFTERSALES Our service department work worldwide every day, on 6 different kind of Nira instruments: E-mail, remote and phone service. More than 500 interventions performed per year. More than 1000 instruments serviced worldwide. Less than 5 working days to organize an intervention within Europe, 10 world