MST 410 Portable multi-gas detector & alarm
Open the catalog to page 1Portable multi-gas detector Manual
Open the catalog to page 2Portable multi-gas detector Manual I. Overview This portable multi-gas detector,It can continuously detect a variety of gas concentrations, easy to use,for personal protection.It has a color TFT display, loud buzzer, alarm indicator and vibration alarm.The detector has an optional wireless function for remote data transmission and personnel location. Detector conforms to standards related provisions and requirements: GB3836.1-2021《爆炸性环境第 1 部分:设备通用要求》 GB3836.2-2021《爆炸性环境第 2 部分:由隔爆外壳“d”保护的设备》 GB3836.4-2021《爆炸性环境第4 部分:由本质安全型“i”
Open the catalog to page 3Portable multi-gas detector Manual 3.Automatic calibration after replace new sensor, immediate use 4.Optional wireless module,for remote data trans,person location 5.Fall alarm function 6.The screen display can be inverted 7.Optional gas concentration unit 8.Full function test at startup 9.The monitoring of abnormal operation of the detector 10.Temperature monitoring 11.Calibration overdue reminder 12.Color TFT display,continuous real-time data display 13.Sound,light,vibration alarm modes 14.Built-in rechargeable lithium-ion battery 15.Coated anti-static shell 2
Open the catalog to page 4Portable multi-gas detector Manual III. Specifications 1. Gas type and measuring range: No. carbon monoxide(CO) combustible gas(LEL) hydrocyanic acid(HCN)
Open the catalog to page 5Portable multi-gas detector Manual 11 hydrogen fluoride(HF) hydrogen chloride(HCL) 2. Battery parameters: rated voltage 3.7V,nominal capacity 3000mAh 3. Working current: Normal current:<120mA (when the screen is off) Alarm current:<240mA 4. Explosion-Proof: Ex ib IIC T4 Gb(CLEx), II 1G Ex ia IIC T4 Ga(ATEX) 5. Sensor type: Combustible gas: catalytic combustion
Open the catalog to page 6Portable multi-gas detector Manual CO,H2S,NH3,CL2,NO2,HCN,PH3 and etc.toxic gas:electrochemistry CO2: Nondispersive infrared VOC:PID 6. Sampling method: Diffuse 7. Response time: combustible gas:T90<60s Toxic gas ammonia, hydrocyanic acid, ozone gas within 160s, phosphine within 100s,The response time of other toxic gases is within 60s 8.Continuous working time on full charge:≥ 15H 9.Accuracy: CO:±10%FS H2S:±10%FS LEL:
Open the catalog to page 7Portable multi-gas detector Manual Othertoxic gases: within ± 10% (display value) or ± 5% (full scale), take minimax value 10. Working Environment: Temp.: -20℃∼55℃ Humidity: 0%∼95%RH, no condensation 11. Storage Conditions Temp.: -40℃∼55℃ Humidity: ≤90%RH, no condensation 12. Charging temperature range: 0℃∼40℃ 13. Carried Stard: GB12358-2006,GB3836.1-2021,GB3836.2-2021,GB3836.4-2021 14. Case material: ABS,PC,antistatic TPE 15. Size: 130mm×74mm×37mm 16
Open the catalog to page 8Portable multi-gas detector Manual IV. System structure and working
Open the catalog to page 9Portable multi-gas detector Manual 2). Description of the main screen 1.Working status area: Normal is white, failure is yellow, alarm is red. 2.Battery capacity: Shows the amount of battery left. fig 2 3. Wireless: Icon indicates detector has wireless,otherwise not. 4. Voice:
Open the catalog to page 10Portable multi-gas detector Manual 5.SMS: It shows that there are new messages unread. 6. Temp.: It shows the current temperature. 7.Time: It shows the current time. 8.Data display area: Shows measured gases and realtime value. 3). The light indicator's description 1.Green light: It sparkles. The detector is working. 2.Yellow light: It sparkles.The detector is faulty. 3.Red light: When low alarm,the red light flashes once per second; When high alarm,the red light flashes twice per second; 4). Description of the keys 、 SET key Detector has 5 buttons, ON/OFF key
Open the catalog to page 11Portable multi-gas detector Manual Down key 1、ON/OFF key In the off state,long press for about 3 seconds to turn on. In the on state,long press for about 5 seconds to power off. On the Settings interface,press once to confirm. In alarm and fault state, press once to mute or unmute. 2、SET key On Normal interface,long press for 3 seconds to enter the password interface.The correct password lead to Settings. On the Settings,press once to back to previous menu. 3、UP key On Normal interface,press once to show the sensor information. On the Settings,press to turn page up or increase...
Open the catalog to page 12Portable multi-gas detector Manual On Normal interface,press once to show the sensor information. On the Settings,press to turn page down or reduce the digit. 5、Emergency key SOS Wireless detector sends a sos to connected phone or computer. Non-wireless detector sends local alarm for help. 5). Working principle The detector adopts diffusion sampling.The sensor converts the collected gas concentration signal into a voltage signal, which is amplified and calculated intelligtively by the IC and then converted into digits show on the screen. If the measured value exceeds the limited value,the...
Open the catalog to page 13Portable multi-gas detector Manual 1) Start up Long press On/Off key for more than 3 seconds, then the device will start up. 2) Self test Detector is turned on, it shows the model and user ID first. If the detector has wireless,user's ID can be changed.Otherwise the user's ID is "health and peace". During self-test,the internal circuit, light, vibration and sound are tested successively, as shown in Figure 3.
Open the catalog to page 14Portable multi-gas detector Manual After self-test passes,the machine configuration info will be displayed, as shown in Figure 4. Then the info of sensors is displayed, as shown in Figure 5. If the zero-calibration function is turned on,detector will perform zero calibration after 5s.User can cancel it during 5s. After zero calibration,it displays pass or not. The zeroing process is shown in Figure 6,7,8.
Open the catalog to page 15Portable multi-gas detector Manual 2. Power off The detector is on normal interface,press On/Off key for more than 5s,it shown as in Figure9. Continue to hold thebutton until it power off. If release the On/ Off key during the process, the detector will return to the normal interface. 3. Working statements 1) Normal working state
Open the catalog to page 16Portable multi-gas detector Manual When the detector is working,it should show the Normal interface,as shown in FIG.10. the green light flashes once/5 sec. If powersaving mode is on,and there are no detection ofalarms or anomalies,and no operation, detector will turn off the screen after 1 min. 2) Alarm When alarms,the red light will flash,the alarm item will be displayed in the status bar, and there will be a red flashing sign in the data area.Red light blinks once/sec at low alarm.Red light blinks twice/sec at high alarm.There is a buzzer sound and vibration (sound/vibration is on in the Settings)...