MST101 Portable single gas Detector & alarm (Ver.1.0) The manual is subject to change without prior notice User's Manual

 Open the catalog to page 1
MaiYa MST101 single gas detector manual-2

MST101 single gas detector manual

 Open the catalog to page 2
MaiYa MST101 single gas detector manual-3

MST101 single gas detector manual MST 101 single gas detector is a high-quility detector which with fall alarm, OLED display, wide range of working temp. Screen is visible in sunlight. The shell is covered with anti-static rubber, so it has good sealing, waterproof and dustproof. can meet the explosion-proof use requirements. By assembling different sensors, the detector can detect a variety of dangerous gases. 1. OLED display can continuously show gas concentration in real time 2. English menu operation mode 3. Automatic zeroing calibration when starting up (It can be set to on/off)

 Open the catalog to page 3
MaiYa MST101 single gas detector manual-4

MST101 single gas detector manual 4. It offers a variety of concentration units that can be switched 5. Fall alarm function (It can be set to on/off) 7. Compact, light weight, easy to carry 8. With sound, light, vibration of three alarm modes 9. With alarm types of low limit, high limit, STEL, TWA 10. It supports changing alarm points 11. The sensor has temperature compensation 12. Detecting and displaying temperature 13. Reminder of calibration’s overdue 14. Starting up self-test, including sensor, circuit board, light and alarm test. 15. Rechargeable lithium-ion polymer battery 16. Anti-fall,...

 Open the catalog to page 4
MaiYa MST101 single gas detector manual-5

MST101 single gas detector manual III. Specifications 1. Gases/range, It can be customized No. Product Model carbon monoxide(CO) hydrocyanic acid(HCN)

 Open the catalog to page 5
MaiYa MST101 single gas detector manual-6

MST101 single gas detector manual 2. Battery parameters: rated voltage 3.7V, capacity 500mAh Normal current: <0.1mA (when the screen is off) Oxygen: The Kavani battery

 Open the catalog to page 6
MaiYa MST101 single gas detector manual-7

MST101 single gas detector manual Combustible gas: Infrared sensor 6. Detection method: Diffused Response time: For ammonia, hydrocyanic acid, ozone: < 60s. Phosphine: <100s. For other toxic gases: < 30s. Relative humidity: 0% ~ 95%, no condensation

 Open the catalog to page 7
MaiYa MST101 single gas detector manual-8

MST101 single gas detector manual 10. Charging temperature range: 0°C ~ 40°C 12. Shell material: ABS, PC, antistatic TPE 13. Overall size: 93mm*52mm*30mm (without back clip)

 Open the catalog to page 8
MaiYa MST101 single gas detector manual-9

MST101 single gas detector manual

 Open the catalog to page 9
MaiYa MST101 single gas detector manual-10

MST101 single gas detector manual 2. Description of main display interface 4

 Open the catalog to page 10
MaiYa MST101 single gas detector manual-11

MST101 single gas detector manual 2.1. Battery power icon: It displays the remaining battery level. 2.2. Working status show: It display detector’s working status. When it is normal, the system displays the picture as shown in fig 3. When it is alarmed, the display shows as picture in fig 2 : 2.3. It displays the current time. It can be adjusted in "Setting". 2.4. Sound icon: When there is a alarm or fault, press ® key to switch the mute/stop mute state, and the prompt icon will change accordingly. ^ means the sound is off. a^') means the sound is on. 2.5. It displays the current temperature.

 Open the catalog to page 11
MaiYa MST101 single gas detector manual-12

MST101 single gas detector manual 2.6. Concentration value: It display the realtime value of the measured gas. 2.7. Concentration unit: It displays the current gas concentration unit, which can be changed in "Setting" 2.8. Target gas: It display the name of measured gas. 2.9. Alarm icon: When alarm, the heart icon will flash. 3.1. Green light: It flashes once / 5sec, the detector is working normally. 3.2. Yellow light: It flashes once / 6sec, it indicates that the detector is faulty. 3.3. Red light: It flashes once / 2 sec, the detector is in alarm. The detector has 3 keys, namely the On/Off...

 Open the catalog to page 12
MaiYa MST101 single gas detector manual-13

MST101 single gas detector manual 4.1.1. When detector is at off, long press it for 3 seconds to turn on the detector. 4.1.2. On non-setting interface, long press it for 8 seconds to power off. 4.1.3. On the setting interface, click it to perform the confirmation. 4.1.4. When detector is alarming, click it to turn on or off the sound. 4.2.1. In the main interface, click it to Switch screen to view the real time value, Unit, STEL/TWA/PEAK, Range, Alarm point. As shown in fig 4 and fig 5.

 Open the catalog to page 13
MaiYa MST101 single gas detector manual-14

MST101 single gas detector manual 4.2.2. In setting interface, click to turn the page up or down, and increase or decrease the value. 4.3. In the main interface, press the On/Off key O and the down key ^ at the same time for 3 sec, it leads to the system Settings. (In this case it need to enter the password) 4.4. In die main interface, press the up key and down key ^ at the same time to return. The sensor will convert the collected gas concentration signal into a voltage signal, which will be amplified and then displayed by the MCU after sampling and intelligent calculation. If the measured concentration...

 Open the catalog to page 14
MaiYa MST101 single gas detector manual-15

MST101 single gas detector manual 1.1. Start up: Press and hold the On/Off key for more than 3 seconds when the device is powered off, then the device will start up. After the detector is started, it displays the name and model of the company, then the sound, light, vibration and internal circuit will be tested successively, as shown in Figure 6:

 Open the catalog to page 15
MaiYa MST101 single gas detector manual-16

MST101 single gas detector manual After the self-test, if there is not faulty, it leads to display of info that includes measured gas, range, low indicator, high indicator, time from next calibration, software version, etc., as shown in fig 7. Then if the “Auto Cal” is enabled, the zero calibration procedure is executed. If the “Auto Cal” is not enabled, it’ll leads to the main interface, as shown in fig 3.

 Open the catalog to page 16
MaiYa MST101 single gas detector manual-17

MST101 single gas detector manual Press and hold the On/Off key for more than 3 seconds in the main interface, countdown appears on the interface for power off, the detector will be displayed as shown in Figure 8. Keep holding the key down untill it appears 0. If user release the On/Off key during the countdown, the detector will return to the main interface.

 Open the catalog to page 17
MaiYa MST101 single gas detector manual-18

MST101 single gas detector manual If detector is in the normal detection state, The main screen displays "Normal". The green light blinks once every 5 seconds. If the detector does not detect the alarm and fault information, and there is no any keys operation, in about 18 seconds, it will go into power-saving mode, the screen will be off, but the green light still kept blink every 5 seconds. a) The red light will flash once every 2 seconds when the detector is in the state of low alarm, STEL alarm or TWA alarm. If the sound is not silenced, detector will intermittently chirp, and keep vibrating....