The Laser Gas Sensor 4Series by Ningxia Maiya Sensor Technology Development Co., LTD is a high-precision methane sensor utilizing Tunable Diode Laser Absorption Spectroscopy (TDLAS) technology. It offers good stability, unique selectivity to methane, fast response, and high accuracy without the need for calibration. The sensor is shockproof, waterproof, and dustproof, with dual output options via TTL serial port and analog signal.
Product Specifications:
  • Object Gas: Methane
  • Sampling Method: Diffusion
  • Response Time: ≤20 seconds
  • Measurement Range: 0-1%VOL (10000ppm), 0-5%VOL, 0-100%VOL
  • Accuracy: 0-1% ±0.03%VOL; 1%-100% ±5% of true value
  • Display Resolution: 0.01%VOL
  • Expected Life: > 5 years
  • Operating Temperature: -5℃ to +55℃ (customizable from -40℃ to +70℃)
  • Humidity: <98%RH (no condensation)
  • Pressure Range: 86Kpa to 106Kpa
  • Voltage: 3V-5.5V
  • Current: <100mA
  • Communication: TTL serial port and dual 0.4V-2V analog outputs
  • Material: 304 stainless steel
  • Dimensions: Φ20mm x 16.6mm
  • Protection Level: IP65
Size and Pin Definition:
  • V+: Power input (3.0V-5.5V DC)
  • Gnd: Ground
  • Tx/Rx: Serial port transmitter/receiver
  • DA: Analog Voltage Output Terminal
  • OV: Sensor Fault Indicator
TTL Serial Port Data Usage Guide:
  • Porter Rate: 38400
  • Data Packet Format: ASCII codes with checksum calculation
  • Commands: F1 for active transmission, F0 for passive response, R6 for reading concentration data
Transportation and Storage:
The sensor is suitable for various transportation modes and must be protected from water and collision. It should be stored at room temperature away from corrosive gases.
Precautions:
  • Ensure correct power connection and normal voltage before use.
  • Avoid disassembly or repair in explosive environments.
  • Keep away from high temperatures and fire sources.
  • Use a dedicated adapter for external wiring during testing.
  • Comply with GB/T 3836.15-2017 for installation.
Contact Information:
Ningxia Maiya Sensor Technology Development Co., LTD, Yinchuan Zhongguancun Innovation Center A Building, Helanshan Road, Xingzhou Street, Yinchuan City. Email: [email protected], Tel: +86 189 9527 8133/13995001037, Whatsapp: +86-17045980316, Website: maiya-sensor.com
See more

Catalog excerpts

MaiYa  MST LS4 laser methane gas sensor-1

The LS4 series laser methane sensor is a high-precision, miniaturized gas sensor designed based on Tunable Diode Laser Absorption Spectroscopy (TDLAS) technology. It features small size, low power consumption, stable performance, long service life of sensor components and high sensitivity. • Good stability, no calibration required; • Unique selectivity to methane, not interfered by other gases, water vapor or dust; • Fast response speed, wide measurement range and high measurement accuracy; • Shockproof, waterproof and dustproof performance; • TTL serial port and analog signal dual output;

 Open the catalog to page 1
MaiYa  MST LS4 laser methane gas sensor-2

Table 1: Room Temperature Linear Test Data

 Open the catalog to page 2
MaiYa  MST LS4 laser methane gas sensor-3

Size and Pin Definition Pin symbol TTL Serial Port Data Usage Guide l.Porter rate: 38400 Data Bit: 8; Stop Bit: 1; Parity Bit: None 2. Data Packet Format Data Area Tab Check Area Carriage Return Carriage Return 1. A data packet is a string composed of ASCII codes. 2. Checksum = 100 (Hex) - (function code + data 1 + ... + dataN).For example: Ningxia Maiya Sensor Technology Development Co., LTD

 Open the catalog to page 3
MaiYa  MST LS4 laser methane gas sensor-4

Laser gas sensor 4series If the calculated checksum is 0x89, the corresponding high byte is 0x38 (ASCII character "8") and the low byte is 0x39 (ASCII character "9"). If the calculated checksum is 0xAC, the corresponding high byte is 0x41 (ASCII character "A") and the low byte is 0x43 (ASCII character "C"). 3. F1 Command (Enter F1 Active Transmission Mode) Instruction: When it is necessary to enter F1 automatic data transmission mode (the sensor is in F1 automatic data transmission mode at factory), send the following command. After receiving the command, the sensor will periodically print and...

 Open the catalog to page 4
MaiYa  MST LS4 laser methane gas sensor-5

It is recommended to use a dedicated adapter for external wiring welding during independent testing. For products that have passed explosion-proof inspection, do not arbitrarily replace or modify components and structures that affect explosion-proof performance. Installation must comply with the requirements of GB/T 3836.15-2017 Explosive Atmospheres - Part 15: Design, Selection and Installation of Electrical Installations. Do not attempt to disassemble or repair the sensor by yourself. Ningxia Maiya Sensor Technology Development Co., LTD Address: Yinchuan Zhongguancun Innovation Center A Building,...

 Open the catalog to page 5

All Ningxia Maiya Sensor Technology catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.