Overview of Product
The MST 410P is a portable multi-gas detector designed for personal protection, capable of detecting multiple gas concentrations continuously. It features a color TFT display, high-decibel buzzer, alarm indicator, and vibrator to alert users when gas concentrations exceed safe limits. It is equipped with smart sensors, data storage, and optional Bluetooth data transfer, making it suitable for industries like metallurgy, petrochemical, and emergency rescue.
Features
The MST 410P includes a quick-start pump, blockage detection, visual dust filter, and support for up to five gases. It uses smart sensors that can be easily replaced and identified by the detector. Additional features include data storage, Bluetooth transfer, fall alarm, SOS button, selectable gas concentration units, self-monitoring, calibration reminders, temperature display, and a durable antistatic shell.
Specifications
The detector measures gases such as CO, H2S, O2, and more, with specific ranges for each. It operates on a rechargeable lithium-ion battery and has an explosion-proof grade. The device uses various sensor types and a pump sampling method, offering a response time of less than 30 seconds for most gases and a continuous working time of over 15 hours on a full charge. It operates in temperatures from -20℃ to 55℃ and has specific storage conditions.
System Structure and Working Principle
The MST 410P features a structured display interface showing working status, battery capacity, wireless connectivity, and more. It uses a sensor to react with target gases, producing signals that are processed to determine gas concentrations. If concentrations exceed set limits, alarms are triggered. The device can also transmit data wirelessly for remote monitoring.
Operation Instructions
To power on, hold the On/Off button for 3 seconds. The device performs a self-test and pump test upon startup. Users can switch between normal and sensor information screens, mute alarms, and enter settings using a password. The settings menu includes options for messages, data recording, time adjustment, sensor management, pump settings, and calibration.
Maintenance Precautions
Regular maintenance includes checking the pump and sensors, ensuring proper calibration, and replacing components as needed to maintain accuracy and functionality.
Solutions of Common Faults
The manual provides troubleshooting steps for common issues such as pump blockages, sensor errors, and calibration failures.
Accessories List
The detector comes with various accessories, including chargers, calibration kits, and protective cases.
Warranty
The MST 410P is covered by a warranty that outlines the terms and conditions for repairs and replacements.
Alarm Settings
Users can configure alarm points and types for different gases. Combustible gases and oxygen have low and high alarm points, while toxic gases like H2S, CO, and NH3 have additional STEL and TWA thresholds. Alarm types include light, sound, and vibration.
Default Alarm Points
The manual provides default alarm thresholds for various gases, such as CO, H2S, O2, and others, with specific low, high, STEL, and TWA values.
Other Settings
Includes auto-calibration, screen rotation, fall alarm, unit selection, calibration overdue warning, screen brightness, and wireless settings. Auto-calibration ensures zero-point accuracy at startup, and the fall alarm triggers if the detector remains stationary for 25 seconds.
Battery and Charging
The battery icon indicates charge level, with a full charge shown by four bars. Charging should occur in a safe environment, and the detector should be off during charging.
Maintenance Precautions
Regular calibration every six months is recommended. Avoid exposure to high concentrations of certain gases to prevent sensor poisoning. Use only original batteries and avoid cleaning with harmful substances.
Common Faults and Solutions
The manual lists common faults such as system failure, memory error, and sensor issues, along with recommended solutions like recalibration or returning the device for service.
Accessories and Warranty
The package includes a user manual, power adapter, sampling probe, dust filters, PVC hose, and calibration certification. A one-year warranty covers material and process defects, excluding man-made damage or misuse.
See more

Catalog excerpts

MaiYa MST 410P portable multi- gas detector manual-1

MST410P Portable pumping multi-gas detector (Ver.1.0) The manual is subject to change without prior notice User's Manual

 Open the catalog to page 1
MaiYa MST 410P portable multi- gas detector manual-2

MST 410P pump multi-gas detector manual

 Open the catalog to page 2
MaiYa MST 410P portable multi- gas detector manual-3

MST 410P pump multi-gas detector manual Ⅰ. Overview of product MST 410P Portable Multi-Gas Detector is a pumping gas detector for personal protection that continuously detects the concentration of multiple gases. The colour TFT display shows the concentration of the detected gases and other information. A buzzer with a high decibel level, the alarm indicator, and a vibrator work together to alert the user that the current gas concentration has exceeded the limit alarm point. The detector uses smart sensors, which are easy to maintain. It has built-in program to reach many functions. The detector...

 Open the catalog to page 3
MaiYa MST 410P portable multi- gas detector manual-4

MST 410P pump multi-gas detector manual The pump can be turned off and started quickly in order to save electricity during use. Blocking pump detection. The detector alerts the user when the pump is blocked in use. It has visual dust filter, easy to observe it’s dirty and replace it. It supports up to 5 gases (CO/H2S must be selected in this case of 5 gases). The detector uses smart sensors. The smart sensor can be installed at will and the detector will automatically identify it. This make it to detect any gas by simply replacing the smart sensor. Optional data storage(event recording and data...

 Open the catalog to page 4
MaiYa MST 410P portable multi- gas detector manual-5

MST 410P pump multi-gas detector manual The detector can monitor its own working state, alarm and indication when it fails. 10. Calibration date countdown can be viewed. Calibration overdue reminder. 11. It displays sensors temperature, sensor has temperature compensation. 12. Color TFT display, it shows real-time data clearly and inimitably. 13. Display follows gravity, the screen is always positive when the meter is turned upside down. 14. Detector has rubber antistatic shell, durable, anti-static.

 Open the catalog to page 5
MaiYa MST 410P portable multi- gas detector manual-6

MST 410P pump multi-gas detector manual III. Specifications 1. Gases and measuring range: (Please contact us for other customized gases or ranges) No. Gas type Range 1. carbon monoxide(CO) hydrogen sulfide(H2S) oxygen(O2) combustible gas(Ex)

 Open the catalog to page 6
MaiYa MST 410P portable multi- gas detector manual-7

MST 410P pump multi-gas detector manual hydrocyanic acid(HCN) hydrogen fluoride(HF) hydrogen chloride(HCL) 2. Rechargeable polymer lithium-ion battery: rated voltage 3.7V, nominal capacity 5200mAh 3. Working current: Normal current:

 Open the catalog to page 7
MaiYa MST 410P portable multi- gas detector manual-8

MST 410P pump multi-gas detector manual 4. Explosion-proof grade: Ex ib IIC T4 Gb(CLEx), II 1G Ex ia IIC T4 Ga(ATEX) 5. Sensor type: Combustible gas: catalytic combustion, or infrared(NDIR) CO,H2S,NH3,CL2,NO2,HCN,PH3,O2,HCL,HF,SO2 and etc. Toxic gas: electrochemistry 6. Sampling method: pump sampling 7. Response time: Combustible gas:T90<30s Oxygen:T90<30s Toxic gas:ammonia, hydrocyanic acid within 120s, phosphine within 60s, other toxic gas response time within 30s 8. Continuous working time of full charge: ≥15h 9. Accuracy: 6

 Open the catalog to page 8
MaiYa MST 410P portable multi- gas detector manual-9

MST 410P pump multi-gas detector manual CO: ±10% H2S: ±10% LEL: ±5%FS O2: ±3.0%FS Other toxic gases: ±10% (displayed value) or ±5% (full scale) within the maximum 10. Working Environment: Temp.: -20℃~ 55℃ Humidity: 0% ~ 95%RH, no condensation 11. Storage Conditions: Temperature: -40℃~ 55℃ Relative humidity ≤90%RH, no condensation 12. Charging temperature ran

 Open the catalog to page 9
MaiYa MST 410P portable multi- gas detector manual-10

MST 410P pump multi-gas detector manual Carried Stard:GB12358-2006,GB/T3836.1-2021,GB/T3836.4-2021 Case material: ABS, PC, antistatic TPE Overall size: 161mm×76mm×57mm (including back clip thickness) Weight: About 450 g

 Open the catalog to page 10
MaiYa MST 410P portable multi- gas detector manual-11

MST 410P pump multi-gas detector manual IV. System structure and working principle 1 . Appearance structure drawing

 Open the catalog to page 11
MaiYa MST 410P portable multi- gas detector manual-12

MST 410P pump multi-gas detector manual 2. Description of main display interface

 Open the catalog to page 12
MaiYa MST 410P portable multi- gas detector manual-13

MST 410P pump multi-gas detector manual (1) Working status area: Display the working status of detector. Normal is white, failure is yellow, alarm is red. (2) Battery capacity: Shows the amount of battery left. (3) Wireless: Icon indicates detector has wireless,otherwise not. (4) Voice: (5) SMS : It shows that there are new messages unread. (6) Air pump : means working normal, means pump blockage. (7) Temp.: It shows the current temperature. (8) Time:It shows the current time. 3. The description of the light indicates (1) Green light: It sparkles: Alarm is working properly. (2) Yellow light:...

 Open the catalog to page 13
MaiYa MST 410P portable multi- gas detector manual-14

MST 410P pump multi-gas detector manual 4. Description of the button Detector has 5 buttons, ON/OFF button button , and Emergency help button SOS. 1) On/Off button :  In the off state, press and hold button for about 3 seconds to turn on the detector. In the on state, press and hold button for about 5 seconds to power off the detector. On the settings interface, press it to confirm. For alarm and fault status, press it to mute or unmute. It can works with on/off button, it can be used for detector self-test. On the normal interface, hold it for 3s to enter the password menu. On settings interface,...

 Open the catalog to page 14
MaiYa MST 410P portable multi- gas detector manual-15

MST 410P pump multi-gas detector manual  When the pump is not detected at detector’s startup, hold it for 3s to turn off the pump. 3) Up button :  On normal screen, press it to view sensor info and STEL/TWA value.  On settings interface, press it to scroll up or increase the digits. On normal screen, hold it for 3s to pause the pump or run the pump. 4) Down button :  On normal screen, press it to view sensor info and STEL/TWA value.  On settings interface, press it to scroll down or decrease the digits. 5) SOS emergency help button:  Press it, the detector emits sound and light vibration...

 Open the catalog to page 15
MaiYa MST 410P portable multi- gas detector manual-16

MST 410P pump multi-gas detector manual The sensor reacts with the target gas to produce a voltage or current signal. After the signal is amplified by circuit, the single chip microcomputer samples and calculates the measured concentration. If the measured concentration exceeds the alarm concentration setting value, alarm signals such as sound, light and vibration are sent out. If the detector has optional 4G wireless remote transmission module, managers can view the data of the detector and the location of the detector(wearer) on the PC or mobile data platform. V. Operation instructions 1. Power...

 Open the catalog to page 16

All Ningxia Maiya Sensor Technology catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.