1. Catalogs
  2. Ningxia Maiya Sensor Technology
  3. Dot type toxic gas detector MP840

Dot type toxic gas detector MP840

Dot type toxic gas detector MP840

Dot type toxic gas detector MP840

Product catalog summary
Overview: The VOXI MP840 is a point-type toxic gas detector designed for fixed installations in industries such as oil and gas, petrochemical, chemical, metallurgy, pharmaceutical, and semiconductor. It features a modular design with intelligent sensor detection technology, intrinsic safety, and explosion-proof capabilities.
Key Features:
  • Intelligent processing platform with Smart sensor technology for sensor interchange, off-line calibration, and zero self-calibration.
  • Supports 4~20mA analog, RS485 digital signal output, and optional wireless output.
  • Programmable switching output module and support for Hart protocol and SIL3 certification.
  • Non-invasive infrared remote control and integrated sound and light alarm.
  • IP67 protection level and easy-to-clean sensor and light source.
Universal Transmitter Platform:
  • Supports over 30 gas sensor platforms with standard three-wire 4~20mA, RS485 Modbus, and wireless output modes.
  • Aluminum alloy or stainless steel casing with three programmable relays.
  • Adjustable detection concentration range and flexible installation options.
mPower Sensor Technology:
  • 7R Smart sensor module with anti-poisoning features.
  • Off-line calibration and plug-and-play sensor support.
  • Sensor self-diagnosis technology and intelligent temperature and zero compensation algorithm.
  • Automatic calibration expiration reminders.
Specifications:
  • Configuration: Intelligent electrochemical sensor module.
  • Protection Class: IP66.
  • Working Power Supply: 9-30VDC.
  • Ambient Temperature: -40℃ to +70℃ (limit), -40℃ to +55℃ (typical).
  • Output Signal: 4-20mA and RS485 (standard), wireless (optional).
  • Security Authentication: IECEx, China explosion-proof certification, SIL3, HART (pending).
  • Size: 180mm x 213mm x 127mm; Weight: 1.5kg.
  • Installation: Riser/wall mounting.
  • Wireless Transmission Distance: Greater than 2000 meters.
  • Warranty: 1 year.
Sensor Range and Resolution:
  • Carbon monoxide (CO): 0-500 ppm to 0-2000 ppm, 1ppm resolution.
  • Hydrogen sulfide (H2S): 0-200 ppm to 0-1000 ppm, 0.1ppm to 1ppm resolution.
  • Oxygen (O2): 0-30%Vol, 0.1%Vol resolution.
  • Other gases include Ammonia, Chlorine, Nitric oxide, Nitrogen dioxide, Sulfur dioxide, Hydrogen cyanide, Phosphine, Hydrogen gas, Hydrogen chloride, Ethylene oxide, Phosgene, Chlorine dioxide, Fluorine gas, Hydrogen fluoride, Formaldehyde, Acrylonitrile, Methyl mercaptan with varying ranges and resolutions.
Installation and Connection:
  • Multiple connection modes and installation diagrams provided for transverse pipe, standpipe, and wall mounting.
Note: The document advises verifying the latest regulations and standards as information is subject to change.
See more

Catalog excerpts

Dot type toxic gas detector MP840-1

Dot type toxic gas detector MP840 VOXI MP840 is a point-type toxic gas detector with modular design, intelligent sensor detection technology, intrinsic safety plus flame-proof and explosion-proof design, and fixed installation. Its intelligent processing platform and Smart sensor technology realize the functions of sensor interchange, off-line calibration and zero self-calibration. Three-wire system 4~20mA analog and RS485 digital signal output, optional wireless output and other signal transmission mode, programmable switching output module, customized according to user needs, but also support output signal fine-tuning and other functions, convenient system networking and maintenance. Support for Hart protocol as well as Sil3 certification is widely available.Used in oil and gas, petrochemical, chemical, metallurgy, pharmaceutical, semiconductor and other industries. Universal transmitter platform ● Support for more than 30 gas sensor platforms ● Standard three wire 4 ~ 20mA, RS485 Modbus, wireless and other output signal mode can be selected ● Aluminum alloy or stainless steel case ●Three sets of programmable relays are standard ● The detection concentration range can be adjusted ● Wall or pipe installation, easy and flexible mPower sensor technology ●7R Smart Smart sensor module, anti-poisoning ●Sensor support off-line calibration, sensor plug and play ●Sensor self-diagnosis technology, to ensure the maximum effective operation of the sensor, reduce the cost of use ● Intelligent temperature and zero compensation algorithm ●Automatic reminder of expiration of calibration Security guarantee ● Non-invasive infrared remote control ● Integrated sound and light alarm ● Optional standard Hart protocol for remote diagnosis and setting ●IP67 protection level ●Sil3 Security level authentication ● Easy to clean sensor and light source ● Fault code, can i

 Open the catalog to page 1
Dot type toxic gas detector MP840-2

MP840 specifications and instrument indicators Configuration Intelligent (Smart) electrochemical sensor module Sampling mode Protection class Working power supply Ambient temperature -40℃~+70℃ (limit value) -40℃~+55℃ (typical value) Ambient humidity Environmental pressure Output signal 4-20mA and RS485 (Standard) 3 sets of relays (standard) Wireless (Optional) Electrical interface Security authentication IECEx:Ex d IIC T6 Gb(pending) Ex tb IIIC T80℃ Db China explosion-proof certification: Ex d IIC T6 Other certification Metrological certification Shell material Aluminium alloy Installation mode...

 Open the catalog to page 2
Dot type toxic gas detector MP840-3

Hydrogen chloride(HCl) Formaldehyde (HCHO) Carbon monoxide (Resist H2) Hydrogen sulfide (H2S) Oxygen (O2) Ammonia (NH3)

 Open the catalog to page 3
Dot type toxic gas detector MP840-4

MP840 system diagram Connection mode one Connection mode three

 Open the catalog to page 4
Dot type toxic gas detector MP840-5

Dimensions and installation diagram of MP840 Hold the transverse pipe installation Wall mounting Note: Despite our best efforts to ensure the accuracy of this publication, we are not responsible for any errors or omissions. Information and regulations are subject to change at any time, so we strongly recommend that you obtain the latest published regulations, standards, etc. The publication does not form the basis of the contract.

 Open the catalog to page 5

All Ningxia Maiya Sensor Technology catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.