video corpo

VFC Series

VFC Series

VFC Series

Product catalog summary
Overview: The document provides technical specifications and ordering information for the VFC Series Filter+Regulator+Lubricator (FRL) combination units, which are part of the V Series Air Treatment Units. These units are designed to clean and regulate compressed air systems.
Specifications:
  • Filtration Precision: Available in 20μm and 5μm options.
  • Port Sizes: G1/8, G1/4, G3/8, G1/2, G3/4.
  • Drain Types: Semi-Auto, Manual, and Auto drain types.
  • Pressure Ratings: Max working pressure is 1.0Mpa/1.6Mpa, with specific limits for auto drain and low-pressure types.
  • Working Temperature: 5 to 60℃.
  • Lubricator Oil Capacity: 15cc to 30cc, with recommended lubricant ISO VG 32 or equivalent.
Components: The VFC units consist of a filter regulator and a lubricator, which can be ordered separately. Key components include a pressure gauge, oil bowl, and various seals and springs.
Features:
  • The VF unit includes a water separator to remove oil, condensation, and dirt particles from compressed air.
  • The VR unit maintains constant operating pressure despite fluctuations.
  • The proportional lubricator adds oil to the filtered air, with an adjustable drip rate.
Ordering Information: The ordering code specifies the model, series code, filtration precision, and drain type. Additional options include pressure gauge type and thread type.
Dimensions: Detailed dimensions are provided for various models, including measurements for mounting and installation.
See more

Catalog excerpts

VFC Series-1

V Series Air Treatment Units V Series Air Treatment Units Ordering Code VFC Series FRL Combination Exploded View VFC 200 (Type code) (Series code) 200: 200 Body size 300: 300 Body size 400: 400 Body size ( Port size ) Nil: Semi-Auto drain type M: Manual drain type D: Auto drain type ((Pressure gauge) Nil: Pressure gauge N: Square embedded type pressure gauge O: Without pressure gauge Product Feature * The VFC consisted of VFR and VL, each unit can be ordered separately. * The VF with water separator cleans the compressed air of fluid oil, condensation, and dirt particles. For special applications, a 20|jm filter element can be replaced a by 5|jm filter element. * The VR maintains inputting constant operating pressure despite fluctuations in line pressure and the amount of air consumed. * The proportional lubricator adds a regulated quantity of oil to the filtered air. The oil mist content is proportional to the flow and oil can be added during operation. The oil drip rate is controlled by the adjustable bolt. Normally, 1 to 12drops/1000L of air is sufficient. * Max pressure for V Series auto drain is 0.8Mpa. * Max pressure for the Low-pressure type is 0.4Mpa. * Pressure gauges are available at 10 bar or 16 bar, for other pressure ranges please contact VPC. Specifications Model Umbrelln base Filter cartridge

 Open the catalog to page 1
VFC Series-2

V Series Air Treatment Units Main Dimensions B1 D1

 Open the catalog to page 2

All Ningbo VPC Pneumatic Co., Ltd. catalogs and technical brochures

  1. Silencer

    1  Page

  2. MQR Series

    2  Pages

  3. VBA Series

    6  Pages

  4. AS-FS Series

    2  Pages

  5. VNB Series

    2  Pages

  6. VK300 Series

    2  Pages

  7. VPCP Series

    1  Page

  8. VMK Series

    2  Pages

  9. VPC Series

    1  Page

  10. GAG Series

    1  Page

  11. SLP Series

    2  Pages

  12. TWH Series

    2  Pages

  13. CY1S Series

    2  Pages

  14. CP96 Series

    3  Pages

  15. DNC Series

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry