video corpo

Eclipse TE2000 Brochure
28Pages

{{requestButtons}}

Catalog excerpts

Eclipse TE2000 Brochure - 1

Inverted Research Microscope TE2000 Inverted Research Microscope >

Open the catalog to page 1
Eclipse TE2000 Brochure - 3

3. 2. Configured with an epi-fluorescence attachment 3 >

Open the catalog to page 3
Eclipse TE2000 Brochure - 4

Configured with an epi-fluorescence attachmentPFS can also work in brightfield, phase, and DIC observations. > Medium; n: approx 1.35Glass; n: approx 1.5Water: n: 1.333 Oil; n: 1.514 or Air; n: 1.0LED detection light The coverslip surface* is detected by the LED light emitted through the objective.*Interface of glass and medium in immersion applications or glass and air in dry applications. *Patent pending Observation method: Laser TIRF >

Open the catalog to page 4
Eclipse TE2000 Brochure - 5

Nikon Original! Single molecular fluorescence image of YFP label receptor *Patent pending Observation method: DIC Focus is maintained during time-lapse recording 3 m Contours of the cell photobleach 00.10.20.3 (s) Cell: dendrite (part) of a primary dispersion culture cell of a hippocampusTime-lapse image: being photobleached at after 0.3 sObservation method: TIRFNotes:Օ To prevent reduction in transmittance in the near-infrared range (680nm or higher), Nikonrecommends removing the PFS optics from the optical path when PFS is not in use. During observation of fluorescent dyes with...

Open the catalog to page 5
Eclipse TE2000 Brochure - 6

70mm Epi-fl attachment Other attachment >

Open the catalog to page 6
Eclipse TE2000 Brochure - 8

Nikons two process mechanism first removes stray light from the filtercube completely, then absorbs it through the light absorbing material.Therefore stray light is eliminated thoroughly. > Viewed with a conventional filter Viewed with a high quality filter > 7. 7.

Open the catalog to page 8
Eclipse TE2000 Brochure - 9

23C37ںC before correction 37C after correction Aberration can be corrected using the correction ring.When the temperature changes, aberration occurs. >

Open the catalog to page 9
Eclipse TE2000 Brochure - 10

Main bodyPort select address 12345TE2000-PFSEye 100%Right 80% Bottom Front 80%Left 100% TE2000-EEye 20% 100%* > 1 Eye 20%TE2000-UEye 100%Right 80% (Optional) Front 80%Left 100% Eye 20% * > 2 Eye 20%TE2000-SEye 100% Left 80% ֖ Eye 20%* > 3 By changing the optional prism, the light distribution ratio ofthe shaded portions can be changed as below.*1 Right: 100 Front: 100 Left: 80 (Eye: 20)*2 Right: 100 Front: 100 Left: 80 (Eye: 20)*3 Left: 100 The following portions can also be changed by altering themicroscope body.(Optional at the time of purchase) *2 Bottom: 100*3 Right: 100 TE2000-U/E/PFS...

Open the catalog to page 10
Eclipse TE2000 Brochure - 11

Nikon has instituted numerous innovations to providecomfortable operation and reduce strain, even over aprolonged period of operation. Knobs and buttons > Main controls are concentrated in thefront, close to the operator. Nosepiece is inclined to the left for easyhandling. Eye-level riser (as indicated by arrow) External fine focusing unit Ergonomic tube Large stage-handle knob Frequently used buttons and controls are all located at thefront and within easy reach. Fine focusing unit The TE2000-PFS and TE2000-E come with a compactexternal fine focusing unit that can be placed anywhere on the...

Open the catalog to page 11
Eclipse TE2000 Brochure - 12

All four models accept retrofittable motorized accessories,allowing researchers to not only choose the desired combinations,but also to control the microscope from external PCs. Motorized barrier filter wheel > This motorized barrier filter wheel with a turret rotary system can mount up to 8 25mm barrier filters. Flexible motorized operation for a variety of uses A wide variety of motorized accessories are available and canbe controlled by an external computer when a HUB controller is attached. 蕕 Motorized switching of objectives and observation methodsbetween epi-fluorescence, Nomarski...

Open the catalog to page 12
Eclipse TE2000 Brochure - 13

The HUB controller manages all the cables of each motorized unit at the back of the microscope. By connecting to the RS-232C interface of a PC, motorized units can be controlled from the PC. This epi-fluorescence attachment has a built-in motorized illumination shutter. > This motorized excitation filter wheel with a turret rotary system can mount up to 8 25mm excitation filters. > This motorized analyzer is used toremove and insert an analyzer for Nomarski DIC. > All motorized units attached to the microscope can be operated from this control pad with an LCD screen. Filter position labels...

Open the catalog to page 13
Eclipse TE2000 Brochure - 14

10. 9. 8. The Noise Terminator mechanism directsdeviated stray light out of the optical path. This results in images of high contrast and unparalleled S/N ratio. > Each filter/mirror incorporated in these filters has a very sharp rising edge at the corresponding wavelength that minimizes the crossover of signals. Zoom-type lamphouse adapter allows theoperator to increase light intensity.Remote control unit and filter turret usephosphorescent display tags to enhance visibility during operation in dark rooms. 14 >

Open the catalog to page 14
Eclipse TE2000 Brochure - 15

With the new DIC system, it is possible to obtainthe best image appropriate to the needs Uniform coloration > Excellent images with uniform coloration are now possible, at any magnifications, by changing the material composition of the DIC prisms. Using Rotating Senarmont Compensation method The perfect balance of high contrast and high resolution > Polarizer1/4 PlateRotate polarizerto change DIC contrast. DIC Prism Slider de SenarmontCompensator The standard DIC prisms for the system condensercan cover observation at 10X-100X with only twomodules that are greatly balanced in contrast and...

Open the catalog to page 15
Eclipse TE2000 Brochure - 16

Enables high-contrast imagery of minute livingcells > Viewed with a conventional phasecontrast objectiveViewed with an ADL objective Phase contrast is the most popular observationmethod for inverted microscopes. This method does not require the staining of the specimen,therefore you can observe and research precisestructures of living cells without influencing the live organism. CFI Plan Fluor ELWD ADL objectives > 13. 13. 14.14. Nikon developed Apodized phase contrastobjectives to effectively reduce halos, which wasconsidered troublesome with the conventional phase contrast method. The...

Open the catalog to page 16
Eclipse TE2000 Brochure - 19

A packaged set of instrumentation required for cellularmicromanipulation, the NT-88-V3 is ideal for IVF (in-vitro fertilization), ICSI (intracytoplasmic sperm injection), electrophysiology, or biotechnology applications. This all-in-one compact CO > 2 incubator sustains the internaltemperature at 37C with humidity of 90% and CO > 2 of 5%to keep the specimen in a stable and precise condition. Aspecial technique that minimizes focus blur facilitates longhours of time-lapse imaging. With an acrylic plastic enclosure providing easy access to thespecimen area, this accessory utilizes warm air...

Open the catalog to page 19

All Nikon Metrology catalogs and technical brochures

  1. NEXIV VMZ-S

    5 Pages

  2. bw series

    8 Pages

  3. automated ct

    8 Pages

  4. CAMIO8

    16 Pages

  5. ALTERA CMM

    8 Pages

  6. CMM-Manager

    8 Pages

  7. MCAx-MM

    8 Pages

  8. LC60Dx

    4 Pages

  9. LC15Dx

    8 Pages

  10. NWL200

    5 Pages

  11. XT V Series

    12 Pages

  12. VMZ-R Series

    7 Pages

  13. MM-Series

    15 Pages

  14. AZ100M-AZ100

    20 Pages

  15. NIS-Elements

    20 Pages

  16. XC65Dx(-LS)

    2 Pages

  17. XT H Series

    12 Pages

  18. Automated CT

    8 Pages

  19. Focus

    6 Pages

  20. iSpace

    6 Pages

  21. H14L

    4 Pages

  22. gehl-kseries

    2 Pages

  23. BW-Series

    8 Pages

  24. X.Tract

    2 Pages

Archived catalogs

  1. K-Robot

    2 Pages

  2. AMI-3000

    2 Pages

  3. COOLSCOPE

    8 Pages

  4. DXM-1200C

    6 Pages

  5. AMI-3000

    2 Pages

  6. Eclipse FN1

    7 Pages

  7. COOLSCOPE

    8 Pages