Catalog - Electricity meters
37Pages

{{requestButtons}}

Catalog excerpts

Catalog - Electricity meters - 2

Content Device Language Message Specification (DLMS) provides for the exchange of data for intelligent measurement, intelligent energy management and related industries. The IEC 62056-1-0 (2014) standard regulates remote reading of readings from meters, remote control, and also additional services for measurement of any type of energy resource (electricity, water, gas, heat). Based on the International Electrotechnical Commission (IEC) 62056 DLMS/COSEM suite of international standards, IDIS Companion Specifications define precise Use Cases and Options to ensure 100% interoperable smart...

Open the catalog to page 2
Catalog - Electricity meters - 3

The Company started its activity in 1997 and over the years of successful work has grown into a large enterprise with its own engineering department (qualified design and installation engineers, programmers, laboratory). For 27 years of purposeful work the Company has proved to be a reliable and stable partner. An individual approach to the customers needs is the key for long-term strategic partnership. Based on smart energy metering devices, industrial controllers, specialized equipment and developed software, NIK implements and maintains the AMI system that provide full control and...

Open the catalog to page 3
Catalog - Electricity meters - 4

SINGLE-PHASE METER SINGLE-PHASE METER Proper ties Two visual elements Design 1 Active + reactive energy 4 tariffs / 12 zones Optical port Sensors of influence magnetic and electromagnetic fields Battery mode Instantaneous values of power, voltage, amperage Design 2 (additions to design 1) Voltage quality control «RESET» button with configurable actions Modern communication interfaces Two batteries LCD with vector diagram and OBIS codes Terminal block for DIN 43857 Tamper sensor for case and terminal cover Enclosure DIN rail mounting (option) Optoport cover «View» button «RESET» button...

Open the catalog to page 4
Catalog - Electricity meters - 5

SINGLE-PHASE METER SINGLE-PHASE METER Accuracy class for measuring of active energy: EN 50470-1 Table of construction types Accuracy class for measuring of reactive energy: 192 172 192 172 Nominal voltage Operation voltage range Nominal frequency Nominal current Maximum current Meter constant Starting current (reactive energy) Power consumption, no more: in the voltage circuits without PLC interface in the voltage circuits with PLC interface in current circuits Operating temperature Service life Battery lifetime Nominal voltage 2 230 V 3 240 V Active energy measurement 1 Import energy 2...

Open the catalog to page 5
Catalog - Electricity meters - 6

SINGLE-PHASE METER SINGLE-PHASE METER Proper ties DLMS Modern communication interfaces Active and reactive energy Instantaneous values of power, voltage, amperage 4 tariffs / 12 zones Two measuring elements Prepaid functions (option, together with the NOVASYS software package) Voltage quality control Optical port Disconnector Sensors of the influence of magnetic and electromagnetic fields Tamper sensor for case and terminal cover Transparent case Battery mode Active and reactive energy «RESET» button with configurable actions Two batteries LCD with vector diagram and OBIS codes Data...

Open the catalog to page 6
Catalog - Electricity meters - 7

SINGLE-PHASE METER SINGLE-PHASE METER Table of construction types Accuracy class for measuring of active energy: EN 50470-1 Accuracy class for measuring of reactive energy: IEC 62053-23 Nominal voltage Operation voltage range Nominal frequency N I K 2 1 04 ХРXX . XХXХ . Х . ХХ Nominal voltage 2 230 V 3 240 V Active energy measurement 1 Import energy 2 Export and import energy Nominal current Maximum current, Imax Meter constant Sensors of influence of magnetic and electromagnetic fields 0 No sensor M Magnetic field sensor C Electromagnetic field sensor MC Both sensors 6400 imp/(kWAr*h)...

Open the catalog to page 7
Catalog - Electricity meters - 8

SINGLE-PHASE METER SINGLE-PHASE METER Proper ties Pre-payment functions according to STS IEC 62055-41 Active and reactive energy Instantaneous measurements of power, voltage, amperage DLMS STS Modern communication interfaces Keypad Data protection by encryption Remote firmware update Voltage quality control Optical port Disconnector Terminal cover sensor Meter case sensor Transparent case Battery mode Enclosure DIN rail mounting (option)

Open the catalog to page 8
Catalog - Electricity meters - 9

SINGLE-PHASE METER SINGLE-PHASE METER Accuracy class for measuring of active energy: IEC 62053-21 Accuracy class for measuring of reactive energy: IEC 62053-23 Nominal voltage Operation voltage range Nominal frequency Nominal current Maximum current Meter constant 6400 imp/(kWAr*h) Starting current for measuring of active energy Starting current for measuring of reactive energy Placement capacity, no more than: in voltage circuits without PLC interface in voltage circuits with PLC interface Operating temperature Weight, no more than Battery lifetime Service life Table of construction types...

Open the catalog to page 9
Catalog - Electricity meters - 10

SINGLE-PHASE METER SINGLE-PHASE METER Proper ties Last GASP (last breath function) - sending a message to the specified server when there is a power loss with 4G/LTE modules Active and reactive energy Instantaneous measurements of power, voltage, amperage DLMS Two measuring elements Modern communication interfaces Replaceable data transfer module Data protection by encryption Remote firmware update Voltage quality control Optical port Disconnector Terminal cover sensor Meter case sensor Battery mode Enclosure DIN rail mounting (option)

Open the catalog to page 10
Catalog - Electricity meters - 11

SINGLE-PHASE METER SINGLE-PHASE METER Table of construction types Accuracy class for measuring of active energy: EN 50470-1 Accuracy class for measuring of reactive energy: IEC 62053-23 Nominal voltage Operation voltage range Nominal frequency Nominal current Maximum current Meter constant Starting current for measuring of reactive energy Nominal voltage: 2 230 V 3 240 V Active energy measurement 1 Import energy 2 Export and import energy 6400 imp/(kWAr*h) Starting current for measuring of active energy Placement capacity, no more than: in voltage circuits without PLC interface in voltage...

Open the catalog to page 11
Catalog - Electricity meters - 12

SINGLE-PHASE METER SINGLE-PHASE METER Proper ties Pre-payment functions according to STS IEC 62055-41 Last GASP (last breath function) - sending a message to the specified server when there is a power loss with 4G/LTE modules Active and reactive energy Instantaneous measurements of power, voltage, amperage DLMS STS Two measuring elements Modern communication interfaces Replaceable data transfer module Keypad Data protection by encryption Remote firmware update Voltage quality control Optical port Disconnector Terminal cover sensor Meter case sensor Battery mode Enclosure DIN rail mounting...

Open the catalog to page 12

All NIK Electronics catalogs and technical brochures