cad

VLF series
16Pages

{{requestButtons}}

Catalog excerpts

VLF series - 1

VACUUM ACCESSORIES Vacuum Blow-off Control Valve equipped with Blow-off Air & Pressure adjusting needles Add-on Blow-off Controller Vacuum Pad Vacuum generator Vacuum air Blow-off air Blow-off pressure adjustment needle Add-on Blow off Controller is for Vacuum air vacuum generators with vacuum Blow-off air blow-off function and controls (controlled flow) Blow-off air rate blow-off air while maintaining adjustment needle characteristics of vacuum Blow-off pressure adjustment needle generators. ● Blow-off pressure control Blow-off flow control Blow-off air rate adjustment needle Newly added pressure Add-on Blow off Controller control function prevents work-pieces from being blown off. ● Relief function releases unnecessary air and shortens blow-off response time by attaching Add-on Blow-off Controller near Vacuum Pad. Blow-off air Vacuum Pad ※”Blow-off air” is for releasing work-piece from vacuum pad. Prevent work-piece from being blown-off Tiny and light work-piece Rotatable body and fitting make it easy to connect or disconnect tube in any direction. Add-on Blow-off Controller Vacuum Filter Free Holder Fall Prevention Valve 8mm LED Pressure Sensor LED Pressure Sensor Small Sensor Pressure Sensor Wit

Open the catalog to page 1
VLF series - 2

Vacuum Accessories Series VACUUM ACCESSORIES EXTERNAL VACUUM VACUUM CONTROLLER GENERATOR Add-on Blow-off Controller ■ Model Designation (Example) VLF Add-on Blow-off Controller ① VR port size (Vacuum generator side) ② W port size (Work-piece side) ① VR port size (Vacuum generator side) 4 ø4mm Code Port size ② W port size (Work-piece side) Push-In Fitting Joint type Code Port size Taper pipe thread 01 R1/8 ■ Specifications Fluid medium Operating pressure range Setting range of relief valve operating pressure Operating vacuum pressure 751 Small Vacuum Regulator Add-on Blow-off Controller...

Open the catalog to page 2
VLF series - 3

■ How to insert and disconnect 1. How to insert and disconnect tubes (Push-In Fitting) ① Tube insertion Insert a tube into Push-In Fitting up to the tube end. Lock-claws bite the tube and fix it automatically, then the elastic sleeve seals around the tube. Refer to “2. Instructions for Tube Insertion” under “Common Safety Instructions for Fittings” . ② Tube disconnection Make sure to stop air supply before the tube disconnection. VACUUM ACCESSORIES The tube is disconnected by pushing release-ring to release Lock-claws. 2. How to tighten thread Tighten the hexagonal-column with a proper tool...

Open the catalog to page 3
VLF series - 4

Vacuum Accessories Series ■ Characteristics Flow rate characteristics of blow-off air 25 Setting pressure of vacuum generator:0.7MPa Blow-off air rate:60l/min[ANR] Flow rate (l/min[ANR]) VACUUM ACCESSORIES EXTERNAL VACUUM VACUUM CONTROLLER GENERATOR Add-on Blow-off Controller Setting pressure of vacuum generator:0.5MPa Blow-off air rate:47l/min[ANR] 15 Setting pressure of vacuum generator:0.3MPa Blow-off air rate:30l/min[ANR] Number of rotations of Blow-off air rate adjustment needle Pressure characteristics of brow-off air (Pressure supply: 0.5MPa, Tube length: 100mm) 0.025 Small Vacuum...

Open the catalog to page 4
VLF series - 5

Detailed Safety Instructions Before using PISCO products, be sure to read “Safety Instructions” and “Safety Instruction Manual” on page 35-39 and “Common Safety Instructions for Vacuum Series” on page 47-49. Warning 1. Since Add-on Blow-off Controller has an installing direction, please read the catalog thoroughly and confirm before using it. There is a possibility of personal injury or product damage by installing the product in a wrong way. 2. Only air can be used as a fluid medium. Contact us when any other fluid is used. 3. Avoid an excessive tensile force, twisting force, bending,...

Open the catalog to page 5
VLF series - 6

Vacuum Accessories Series VLF VR port (Vacuum generator side): Push-In Fitting / W port Relief port VR port Blow-off pressure adjustment needle Blow-off air rate adjustment needle VACUUM ACCESSORIES Weight CAD (g) file name VLF VR port (Vacuum generator side): Push-In Fitting / compliant Blow-off air rate adjustment needle Add-on Blow-off Controller Blow-off pressure adjustment needle Weight CAD (g) file name Chart Characteristic chart page Relief port Small Vacuum Regulator W port (Work-piece side): Taper Pipe Thread W port (Work-piece side): Push-In Fitting EXTERNAL VACUUM VACUUM...

Open the catalog to page 6
VLF series - 7

■ How to adjust Add-on Blow-off Controller 1. Connect VR port with vacuum generator side and W port with work-piece side. Fully open the blow-off pressure adjustment needle ① and fully close the for blow-off air rate adjustment needle ② . 2. Start the operation of vacuum generator and gradually close the needle ① to adjust the required vacuum condition. Make sure there is no vacuum startup delay. Repeat generating vacuum several times to check the operation goes smoothly. 3. Open the needle ② gradually to supply the proper blow-off air rate. VR port (Vacuum generator side) ② Blow-off air...

Open the catalog to page 7
VLF series - 8

Vacuum Accessories Series VACUUM ACCESSORIES EXTERNAL VACUUM VACUUM CONTROLLER GENERATOR Add-on Blow-off Controller 757 Small Vacuum Regulator Add-on Blow-off Controller

Open the catalog to page 8
VLF series - 9

Safety Instructions SAFETY Instructions  This safety instructions aim to prevent personal injury and damage to properties by requiring proper use of PISCO products.  Be certain to follow ISO 4414 and JIS B 8370 ISO 4414Pneumatic fluid power…Recomendations for the application of equipment to transmission and control systems. JIS B 8370General rules and safety requirements for systems and their components. This safety instructions is classified into “Danger”, “Warning” and “Caution” depending on the degree of danger or damages caused by improper use of PISCO products. Danger Hazardous...

Open the catalog to page 9
VLF series - 10

http://www.pisco.co.jp http://www.pisco.co.jp Disclaimer 1. PISCO does not take any responsibility for any incidental or indirect loss, such as production line stop, interruption of business, loss of benefits, personal injury, etc., caused by any failure on use or application of PISCO products. 2. PISCO does not take any responsibility for any loss caused by natural disasters, fires not related to PISCO products, acts by third parties, and intentional or accidental damages of PISCO products due to incorrect usage. 3. PISCO does not take any responsibility for any loss caused by improper...

Open the catalog to page 10

All NIHON PISCO CO. catalogs and technical brochures

  1. CTB series

    1 Pages

  2. FUS8 series

    3 Pages

  3. 31 & 32 Series

    20 Pages

  4. VP series

    106 Pages

  5. CHA series

    8 Pages

  6. Gripper Series

    15 Pages

  7. SVB Series

    50 Pages

  8. SVA series

    13 Pages

  9. SVR series

    31 Pages

  10. NSB series

    8 Pages

  11. BV series

    8 Pages

  12. HV series

    5 Pages

  13. HPO

    12 Pages

  14. HPU

    12 Pages

  15. PJN series

    15 Pages

  16. KJNC series

    15 Pages

  17. SSJS series

    6 Pages

  18. UE series

    12 Pages

  19. FB series

    1 Pages

  20. CTA series

    1 Pages

  21. SFTN series

    2 Pages

  22. SET series

    1 Pages

  23. SFT series

    14 Pages

  24. ULF series

    12 Pages

  25. UCQ series

    2 Pages

  26. UQ series

    12 Pages

  27. NB series

    12 Pages

  28. NA series

    12 Pages

  29. UD series

    12 Pages

  30. UBS series

    12 Pages

  31. UBT series

    12 Pages

  32. UC series

    1 Pages

  33. UB series

    12 Pages

  34. AK/AS series

    26 Pages

  35. NK series

    18 Pages

  36. Brass Series

    30 Pages

  37. V-0 series

    27 Pages

  38. EG Series

    27 Pages

  39. PP Series

    26 Pages

  40. AP series

    18 Pages

  41. SL series

    16 Pages

  42. P-SUS series

    33 Pages

  43. NS series

    24 Pages

  44. SSP series

    8 Pages

  45. ATS series

    6 Pages

  46. Air Filter

    20 Pages

  47. SFU series

    9 Pages

  48. JP series

    15 Pages

  49. ET series

    11 Pages

  50. EQ series

    19 Pages

  51. CVLU series

    21 Pages

  52. CV series

    24 Pages

  53. JN series

    25 Pages

  54. JSD series

    10 Pages

  55. JSC series

    13 Pages

  56. JS series

    30 Pages

  57. MA series

    16 Pages

  58. RH series

    16 Pages

  59. R series

    16 Pages

  60. PS series

    16 Pages

  61. L series

    41 Pages

  62. FUS20

    7 Pages

  63. GP series

    13 Pages

  64. VUS12 series

    2 Pages

  65. VUS21 series

    14 Pages

  66. VUS8-S series

    22 Pages

  67. JSD series

    10 Pages

  68. JK series

    10 Pages

  69. RVFUP series

    6 Pages

  70. VFL series

    8 Pages

  71. VF series

    22 Pages

  72. ECV series

    8 Pages

  73. VPKE series

    4 Pages

  74. RPV06 Series

    8 Pages

  75. VZ Series

    34 Pages

  76. VX Series

    42 Pages

  77. VQ Series

    4 Pages

  78. VN Series

    40 Pages

  79. VK series

    53 Pages

  80. VJ Series

    34 Pages

  81. VG series

    21 Pages

  82. VRL series

    17 Pages

  83. VVV series

    11 Pages

  84. VLS series

    4 Pages

  85. VM | VC series

    28 Pages

  86. VY series

    24 Pages

  87. VB series

    11 Pages

  88. VH | VS series

    28 Pages

  89. VPHMP series

    12 Pages

  90. VYR series

    5 Pages

  91. HS series

    13 Pages

  92. HML series

    14 Pages

  93. VRG series

    18 Pages

  94. VLM series

    12 Pages

  95. VSPE series

    5 Pages

  96. VT series

    21 Pages

  97. PB series

    13 Pages

  98. JSG series

    17 Pages

  99. pararel

    3 Pages

  100. fitting

    4 Pages

  101. BJSU series

    4 Pages

  102. SC

    15 Pages

  103. SPO

    12 Pages

  104. SP

    13 Pages

  105. RPV pump

    8 Pages

  106. Pre-set

    6 Pages

  107. Flange

    13 Pages

  108. HML

    14 Pages

  109. VYR

    5 Pages

  110. VPLFC

    17 Pages

  111. SVB

    172 Pages

  112. SVR

    39 Pages

  113. 8mm Sensor

    22 Pages

  114. Vacuum Filter

    28 Pages

  115. Vacuum Pen

    21 Pages

  116. cylinder

    22 Pages

  117. FDAbellows

    6 Pages

  118. Oval

    80 Pages

  119. sponge

    50 Pages

  120. mark-free

    34 Pages

  121. flat

    42 Pages

  122. Ultrathin

    34 Pages

  123. packaging bag

    13 Pages

  124. multi-bellow

    46 Pages

  125. bellows pad

    74 Pages

  126. Skid proof pad

    42 Pages

  127. soft pad

    66 Pages

  128. VRL

    17 Pages

  129. VZ

    34 Pages

  130. VX

    42 Pages

  131. VVV

    11 Pages

  132. VQ

    42 Pages

  133. VN

    40 Pages

  134. VLS

    4 Pages

  135. VLM

    12 Pages

  136. VK

    53 Pages

  137. VJ

    34 Pages

  138. VG

    21 Pages

  139. Vacuum Tube

    12 Pages

  140. Twin Coiling

    12 Pages

  141. Tube Cutter

    12 Pages

  142. Insert Ring

    12 Pages

  143. UL series

    12 Pages

  144. K series

    30 Pages

  145. Color Cap

    12 Pages

  146. SSNC series

    13 Pages

  147. SJSC series

    24 Pages

  148. KJSC series

    17 Pages

  149. Check Valve

    4 Pages

  150. JSG

    17 Pages

  151. GENERAL

    106 Pages

  152. Change Valve

    11 Pages

  153. SVA21 Series

    21 Pages

  154. P Series

    71 Pages

  155. SVA20 Series

    43 Pages

  156. BJSU series

    6 Pages

  157. NP68-01e

    17 Pages