cad

VG
21Pages

{{requestButtons}}

Catalog excerpts

VG - 1

VACUUM EXTERNAL VACUUM GENERATOR CONTROLLER VACUUM PAD VACUUM ACCESSORIES Complex Ejector focusing on basic performance Vacuum Generator switch and blow-off valve are united. Select the best combination in accordance with applications. are 3 output types: 1 switch output and 1 analog output type, 2-point switch output type, and cost saving 1 analog output type. Ejector unit Vacuum switch Filter Valve unit (Suction valve / Blow-off valve) Blow-off air rate adjustment needle Air supply port (P)

Open the catalog to page 1
VG - 2

Vacuum Generator Series VACUUM GENERATOR Vacuum Generator VG ■ Model Designation (Example) VG Complex Vacuum Generator ⑧ Vacuum Switch ⑦ Wire lead-out direction ⑥ Valve unit voltage spec ⑤ Air supply port size ④ Vacuum port size ① Vacuum characteristics Code H Performance High-vacuum type Performance Large-flow type Code Performance E High-vacuum at low air supply pressure type ② Nozzle bore Code 05 07 10 L type E type Nozzle H type bore Vacuum level, Suction flow Vacuum level, Suction flow Vacuum level, Suction flow -90kPa -66kPa – 0.5mm 7l/min(ANR) 12l/min(ANR) -93kPa -66kPa -90kPa 0.7mm...

Open the catalog to page 2
VG - 3

Fluid medium VACUUM EXTERNAL VACUUM GENERATOR CONTROLLER Operating pressure range Operating temp. range ■ Suction Valve Specification Valve type Pilot operated poppet valve Rated voltage Power consumption Effective sectional area Manual operation VACUUM ACCESSORIES 5 mm2 Push button (non-lock) ■ Blow-off Valve Specification Valve type Direct operating poppet Rated voltage Power consumption Manual operation Push button (non-lock) ■ Vacuum Switch Specification Model code Output Specification Power requirements Current consumption (when 24VDC supplied) Max. 17mA (1 switch: ON) Max. 25mA (2...

Open the catalog to page 3
VG - 4

Vacuum Generator Series VACUUM GENERATOR Vacuum Generator VG ■ Filter Specification Element material PVF(Polyvinyl formal) Filtering capacity Element model code ■ Characteristics Supply pressure - Final vacuum / Suction Flow / Air Consumption VGH07, VGL07, VGE07 Vacuum characteristics Suction flow (l/min(ANR)) Vacuum characteristics flow 40 type suction 30 H type suction flow E type suction flow 20 Flow rate (l/min(ANR)) Supply pressure:0.5MPa (H, L type) 0.35MPa (E type) Flow characteristics H type Final vacuum H type suction flow E type suction flow Flow rate (l/min(ANR)) Flow rate...

Open the catalog to page 4
VG - 5

1. How to insert and disconnect tubes ① Tube insertion Insert a tube into Push-In Fitting of the vacuum generator VG up to the tube end. Lock-claws bite the tube to fix it and the elastic sleeve seals around the tube. Refer to “2. Instructions for Tube Insertion” under “Common Safety Instructions ② Tube disconnection Make sure to stop air supply before the tube disconnection. VACUUM ACCESSORIES The tube is disconnected by pushing release-ring to release Lock-claws. VACUUM EXTERNAL VACUUM GENERATOR CONTROLLER 2. How to fix the product In order to fix the vacuum generator VG, tighten M3...

Open the catalog to page 5
VG - 6

Vacuum Generator Series VACUUM GENERATOR Vacuum Generator VG ■ Standard Size List Unit combination : Built-in Filter Type Unit combination: Vacuum Switch (digital type) / Built-in Filter Type Ejector Vacuum switch Page Air supply Type to refer port 4mm VG A Type 112 6mm Unit combination: Suction Valve / Blow-off Valve / Built-in Filter Type Page Air supply Type to refer port 4mm VG B Type 112 6mm Silencer Air source Vacuum switch Page Air supply to refer port 4mm 113 6mm Suction pilot valve Unit combination: Vacuum Switch (digital type) / Suction Valve / Blow-off Valve / Built-in Filter...

Open the catalog to page 6
VG - 7

A Type Built-in Filer Type Circuit Ejector CAD Nozzle Bore Final vacuum Suction flow Air consumption Weight (g) (mm) (-kPa) (l/min(ANR)) (l/min(ANR)) file name Vacuum Sensor (digital type) / Built-in Filter Type VACUUM ACCESSORIES Silencer Filter VACUUM EXTERNAL VACUUM GENERATOR CONTROLLER -NA:Hysteresis setting trimmer -NW:SW2 Vacuum setting trimmer 112 -NA:SW Vacuum setting trimmer -NW:SW1 Vacuum setting trimmer Air source Vacuum sensor ※ 1 analog output type does not have Operation indicator LED and Vacuum Setting Trimmer. Tube O.D. øD 4 VGH05B-44- □ VGH07B-66- □ 6 VGH10B-66- □ 4...

Open the catalog to page 7
VG - 8

Vacuum Generator Series VACUUM GENERATOR Vacuum Generator VG VG E-L Type Suction Pilot Valve / Blow-off Valve / Built-in Filter Type Cable lead-out direction: Top Manual button Suction pilot valve Blow-off valve Suction Pilot Valve / Blow-off Valve / Built-in Filter Type Cable lead-out direction: Side Manual button Suction pilot valve Blow-off valve CAD Nozzle Bore Final vacuum Suction flow Air consumption Weight (g) (mm) (-kPa) (l/min(ANR)) (l/min(ANR)) file name 0.5 0.7 1 Chart Characteristic chart page Pilot valve Blow-off air adjustment release needle Model code CAD Nozzle Bore Final...

Open the catalog to page 8
VG - 9

Vacuum Sensor (digital type) / Suction Pilot Valve / Blow-off Valve / Built-in Filter TypeCable lead-out direction: Top -NA:Hysteresis setting trimmer -NW:SW2 Vacuum setting trimmer Blow-off valve Suction pilot valve -NA:SW Vacuum setting trimmer -NW:SW1 Vacuum setting trimmer ※ 1 analog output type does not have Operation indicator LED and Vacuum Setting Trimmer. CAD Nozzle Bore Final vacuum Suction flow Air consumption Weight (g) (mm) (-kPa) (l/min(ANR)) (l/min(ANR)) file name Vacuum Sensor (digital type) / Suction Pilot Valve / Blow-off Valve / Built-in Filter Type Cable lead-out...

Open the catalog to page 9
VG - 10

Vacuum Generator Series VACUUM GENERATOR Vacuum Generator VG Detailed Safety Instructions Before using PISCO products, be sure to read “Safety Instructions” and “Safety Instruction Manual” on page 35-39, “Common Safety Instructions for Vacuum Series” on page 47-49 and “Common Safety Instructions for Vacuum Generator VG & VK” on page 105. Warning 1. Attentions should be paid when pipe resistance is large or a large amount of blow-off air rate is required. Insufficient blow-off air may cause troubles. Make sure to evaluate PISCO products by actual system. 2. The coil in a pilot valve...

Open the catalog to page 10
VG - 11

■ Attaching / Detaching Individual Plug-in Connector  ● Insert the connector into the socket until it stops. ■ Connector Detaching Method  ● Pull out the connector while pushing the latch to the arrowed direction. ■Backside of connector Latch VACUUM ACCESSORIES ■ Attaching / Detaching Individual Plug-in Connector ■AC100V ■ Adjusting Method of Blow-off Air  ● Turn the release needle in the clockwise direction to reduce P blow-off air and counter-clockwise to increase. Air rate: Increase Air rate: Reduce   ※ After adjustment of the blow-off air rate, make sure to Blow-off air rate adjustment...

Open the catalog to page 11

All NIHON PISCO CO. catalogs and technical brochures

  1. CTB series

    1 Pages

  2. FUS8 series

    3 Pages

  3. 31 & 32 Series

    20 Pages

  4. VP series

    106 Pages

  5. CHA series

    8 Pages

  6. Gripper Series

    15 Pages

  7. SVB Series

    50 Pages

  8. SVA series

    13 Pages

  9. SVR series

    31 Pages

  10. NSB series

    8 Pages

  11. BV series

    8 Pages

  12. HV series

    5 Pages

  13. HPO

    12 Pages

  14. HPU

    12 Pages

  15. PJN series

    15 Pages

  16. KJNC series

    15 Pages

  17. SSJS series

    6 Pages

  18. UE series

    12 Pages

  19. FB series

    1 Pages

  20. CTA series

    1 Pages

  21. SFTN series

    2 Pages

  22. SET series

    1 Pages

  23. SFT series

    14 Pages

  24. ULF series

    12 Pages

  25. UCQ series

    2 Pages

  26. UQ series

    12 Pages

  27. NB series

    12 Pages

  28. NA series

    12 Pages

  29. UD series

    12 Pages

  30. UBS series

    12 Pages

  31. UBT series

    12 Pages

  32. UC series

    1 Pages

  33. UB series

    12 Pages

  34. AK/AS series

    26 Pages

  35. NK series

    18 Pages

  36. Brass Series

    30 Pages

  37. V-0 series

    27 Pages

  38. EG Series

    27 Pages

  39. PP Series

    26 Pages

  40. AP series

    18 Pages

  41. SL series

    16 Pages

  42. P-SUS series

    33 Pages

  43. NS series

    24 Pages

  44. SSP series

    8 Pages

  45. ATS series

    6 Pages

  46. Air Filter

    20 Pages

  47. SFU series

    9 Pages

  48. JP series

    15 Pages

  49. ET series

    11 Pages

  50. EQ series

    19 Pages

  51. CVLU series

    21 Pages

  52. CV series

    24 Pages

  53. JN series

    25 Pages

  54. JSD series

    10 Pages

  55. JSC series

    13 Pages

  56. JS series

    30 Pages

  57. MA series

    16 Pages

  58. RH series

    16 Pages

  59. R series

    16 Pages

  60. PS series

    16 Pages

  61. L series

    41 Pages

  62. FUS20

    7 Pages

  63. GP series

    13 Pages

  64. VUS12 series

    2 Pages

  65. VUS21 series

    14 Pages

  66. VUS8-S series

    22 Pages

  67. JSD series

    10 Pages

  68. JK series

    10 Pages

  69. RVFUP series

    6 Pages

  70. VLF series

    16 Pages

  71. VFL series

    8 Pages

  72. VF series

    22 Pages

  73. ECV series

    8 Pages

  74. VPKE series

    4 Pages

  75. RPV06 Series

    8 Pages

  76. VZ Series

    34 Pages

  77. VX Series

    42 Pages

  78. VQ Series

    4 Pages

  79. VN Series

    40 Pages

  80. VK series

    53 Pages

  81. VJ Series

    34 Pages

  82. VG series

    21 Pages

  83. VRL series

    17 Pages

  84. VVV series

    11 Pages

  85. VLS series

    4 Pages

  86. VM | VC series

    28 Pages

  87. VY series

    24 Pages

  88. VB series

    11 Pages

  89. VH | VS series

    28 Pages

  90. VPHMP series

    12 Pages

  91. VYR series

    5 Pages

  92. HS series

    13 Pages

  93. HML series

    14 Pages

  94. VRG series

    18 Pages

  95. VLM series

    12 Pages

  96. VSPE series

    5 Pages

  97. VT series

    21 Pages

  98. PB series

    13 Pages

  99. JSG series

    17 Pages

  100. pararel

    3 Pages

  101. fitting

    4 Pages

  102. BJSU series

    4 Pages

  103. SC

    15 Pages

  104. SPO

    12 Pages

  105. SP

    13 Pages

  106. RPV pump

    8 Pages

  107. Pre-set

    6 Pages

  108. Flange

    13 Pages

  109. HML

    14 Pages

  110. VYR

    5 Pages

  111. VPLFC

    17 Pages

  112. SVB

    172 Pages

  113. SVR

    39 Pages

  114. 8mm Sensor

    22 Pages

  115. Vacuum Filter

    28 Pages

  116. Vacuum Pen

    21 Pages

  117. cylinder

    22 Pages

  118. FDAbellows

    6 Pages

  119. Oval

    80 Pages

  120. sponge

    50 Pages

  121. mark-free

    34 Pages

  122. flat

    42 Pages

  123. Ultrathin

    34 Pages

  124. packaging bag

    13 Pages

  125. multi-bellow

    46 Pages

  126. bellows pad

    74 Pages

  127. Skid proof pad

    42 Pages

  128. soft pad

    66 Pages

  129. VRL

    17 Pages

  130. VZ

    34 Pages

  131. VX

    42 Pages

  132. VVV

    11 Pages

  133. VQ

    42 Pages

  134. VN

    40 Pages

  135. VLS

    4 Pages

  136. VLM

    12 Pages

  137. VK

    53 Pages

  138. VJ

    34 Pages

  139. Vacuum Tube

    12 Pages

  140. Twin Coiling

    12 Pages

  141. Tube Cutter

    12 Pages

  142. Insert Ring

    12 Pages

  143. UL series

    12 Pages

  144. K series

    30 Pages

  145. Color Cap

    12 Pages

  146. SSNC series

    13 Pages

  147. SJSC series

    24 Pages

  148. KJSC series

    17 Pages

  149. Check Valve

    4 Pages

  150. JSG

    17 Pages

  151. GENERAL

    106 Pages

  152. Change Valve

    11 Pages

  153. SVA21 Series

    21 Pages

  154. P Series

    71 Pages

  155. SVA20 Series

    43 Pages

  156. BJSU series

    6 Pages

  157. NP68-01e

    17 Pages