Twin Coiling
1 /12Pages

Twin Coiling

Twin Coiling
1 /12Pages

Catalog excerpts

Twin Coiling-1

TUBE MAKE-TO-ORDER PRODUCTS Two-core Coiling Tube for General Pneumatic Piping Twin Coiling Tube Coiling Tube for General Pneumatic Piping. ● Fine ● Suitable Piping for Plural Actuators. Twin Coiling Tube Fluororesin / Polyamide Tube Clean Room Tube Anti-Spatter Tube Anti-Stalic Tube Tube Binder Tube cutter Insert Ring Tube R

 Open the catalog to page 1
Twin Coiling-2

Tube Series ■ Model Designation (Example) ULF Twin Coiling Tube Twin Coiling Tube ② Tube length (before coiled) ② Tube length (before coiled) Code Standard Tube Multi-core Tube Coiling Tube Twin Coiling Tube ③ Tube color L  ④ Tube color R Code

 Open the catalog to page 2
Twin Coiling-3

■ Specifications Fluid medium Max. operating pressure (20℃ 65%RH) Max. vacuum Operating temp. range Warning ※ The value of max. operating pressure is measured at 20℃ and 65%RH. When Tubes are used in different conditions, consider a safety ratio of the pressure with an enough margin, referring to Burst Pressure Curve. When Tubes are frequently swung and bent, there is a possibility of generating heat between molecules and damaging the products. TUBE MAKE-TO-ORDER PRODUCTS ■ Burst Pressure Curve (Reference value) 10 9 Twin Coiling Tube Fluororesin / Polyamide Tube Clean Room Tube Detailed Safety...

 Open the catalog to page 3
Twin Coiling-4

Tube Series ULF Twin Coiling Tube compliant Twin Coiling Tube TUBE Standard Tube Multi-core Tube Coiling Tube Twin Coiling Tube Model code ※ . Left □ in model code: Replaced

 Open the catalog to page 4
Twin Coiling-5

Safety Instructions SAFETY Instructions  This safety instructions aim to prevent personal injury and damage to properties by requiring proper use of PISCO products.  Be certain to follow ISO 4414 and JIS B 8370 ISO 4414Pneumatic fluid power…Recomendations for the application of equipment to transmission and control systems. JIS B 8370General rules and safety requirements for systems and their components. This safety instructions is classified into “Danger”, “Warning” and “Caution” depending on the degree of danger or damages caused by improper use of PISCO products. Danger Hazardous conditions....

 Open the catalog to page 5
Twin Coiling-6

http://www.pisco.co.jp http://www.pisco.co.jp Disclaimer 1. PISCO does not take any responsibility for any incidental or indirect loss, such as production line stop, interruption of business, loss of benefits, personal injury, etc., caused by any failure on use or application of PISCO products. 2. PISCO does not take any responsibility for any loss caused by natural disasters, fires not related to PISCO products, acts by third parties, and intentional or accidental damages of PISCO products due to incorrect usage. 3. PISCO does not take any responsibility for any loss caused by improper usage...

 Open the catalog to page 6
Twin Coiling-7

Safety Instructions SAFETY INSTRUCTION MANUAL PISCO products are designed and manufactured for use in general industrial machines. Be sure to read and follow the instructions below. 1. Do not use PISCO products for the following applications. ① Equipment used for maintaining / handling human life and body. ② Equipment used for moving / transporting human. ③ Equipment specifically used for safety purposes. 1. Do not use PISCO products under the following conditions. ① Beyond the specifications or conditions stated in the catalog, or the instructions. ② Under the direct sunlight or outdoors. ③...

 Open the catalog to page 7
Twin Coiling-8

http://www.pisco.co.jp http://www.pisco.co.jp 1. Remove dusts or drain before piping. They may get into the peripheral machine / facilities and cause malfunction. 2. When inserting an ultra-soft tube into push-in fitting, make sure to place an Insert Ring into the tube edge. There is a risk of causing the escape of tube and a fluid leakage without using an Insert Ring. 3. The product incorporating NBR as seal rubber material has a risk of malfunction caused by ozone crack. Ozone exists in high concentrations in static elimination air, clean-room, and near the high-voltage motors, etc. As a countermeasure,...

 Open the catalog to page 8
Twin Coiling-9

Safety Instructions 7. Instructions for Tube Disconnection ① Make sure there is no air pressure inside of the tube, before disconnecting it. ② Push the release-ring of the push-in fitting evenly and deeply enough to pull out the tube toward oneself. By insufficient pushing of the releasering, the tube may not be pulled out or damaged by scratch, and tube shavings may remain inside of the fitting, which may cause the leakage later. 8. Instructions for Installing a fitting ① When installing a fitting, use proper tools to tighten a hexagonal-column or an inner hexagonal socket. When inserting a...

 Open the catalog to page 9
Twin Coiling-10

Tube Series Common Safety Instructions for Tubes Before selecting or using PISCO products, read the following instructions. Read the detailed instructions for individual series as well as the instructions below. Warning 1. Avoid any load on Tubes such as tensile strength, twisting and bending. These may cause the crush, burst and escape of Tubes. 2. Protect Tubes from scratches caused by snagging or kinking. It may cause the burst of Tubes. 3. The burst pressure of Tubes drops as temperature rises. Read the operating pressure in the catalog well, and apply safety factor. 4. The minimum bending...

 Open the catalog to page 10
Twin Coiling-11

Caution 1. When bending tubes, observe the minimum bending radius and minimum installation radius. 2. When piping, provide sufficient lengths of tube, considering possible shrinkage. 3. When Tubes are inserted into Push-In Fitting, make sure that cut end surface of Tubes are right angle, without any scratches on the surface and deformations. 4. Note that the effective cross-section area varies by tube length. Refer to Effective Area of Piping in Tube Performance . ■ Minimum Bending Radius & Minimum Mounting Radius   n= Deformation ratio (%). Standard: under 25%   d= Tube O.D.   L= Measured value...

 Open the catalog to page 11
Twin Coiling-12

Tube Series ■ Effective Sectional Area of Piping 1000 500 200 Effective Sectional Area (mm2) Tube Performance 100 50 Tube I.D. ø11 Tube I.D. ø9 Tube I.D. ø7.5 Tube I.D. ø6.5 Tube I.D. ø6(ø5.9) Tube I.D. ø5 Tube I.D. ø4 Tube I.D. ø3.48

 Open the catalog to page 12

All NIHON PISCO CO., Ltd. catalogs and technical brochures

  1. Twin Coupling

    6  Pages

  2. CTB series

    1  Page

  3. FUS8 series

    3  Pages

  4. 31 & 32 Series

    20  Pages

  5. VP series

    106  Pages

  6. CHA series

    8  Pages

  7. Gripper Series

    15  Pages

  8. SVB Series

    50  Pages

  9. SVA series

    13  Pages

  10. SVR series

    31  Pages

  11. NSB series

    8  Pages

  12. BV series

    8  Pages

  13. HV series

    5  Pages

  14. Plarailchain SC

    15  Pages

  15. Plarailchain SP

    14  Pages

  16. HPO

    12  Pages

  17. HPU

    12  Pages

  18. PJN series

    15  Pages

  19. KJNC series

    15  Pages

  20. SSJS series

    6  Pages

  21. UE series

    12  Pages

  22. FB series

    1  Page

  23. CTA series

    1  Page

  24. SFTN series

    2  Pages

  25. SET series

    1  Page

  26. SFT series

    14  Pages

  27. ULF series

    12  Pages

  28. UCQ series

    2  Pages

  29. UQ series

    12  Pages

  30. NB series

    12  Pages

  31. NA series

    12  Pages

  32. UD series

    12  Pages

  33. UBS series

    12  Pages

  34. UBT series

    12  Pages

  35. UC series

    1  Page

  36. UB series

    12  Pages

  37. AK/AS series

    26  Pages

  38. NK series

    18  Pages

  39. Brass Series

    30  Pages

  40. V-0 series

    27  Pages

  41. EG Series

    27  Pages

  42. PP Series

    26  Pages

  43. AP series

    18  Pages

  44. SL series

    16  Pages

  45. P-SUS series

    33  Pages

  46. NS series

    24  Pages

  47. SSP series

    8  Pages

  48. ATS series

    6  Pages

  49. Air Filter

    20  Pages

  50. SFU series

    9  Pages

  51. JP series

    15  Pages

  52. ET series

    11  Pages

  53. EQ series

    19  Pages

  54. CVLU series

    21  Pages

  55. CV series

    24  Pages

  56. JN series

    25  Pages

  57. JSD series

    10  Pages

  58. JSC series

    13  Pages

  59. JS series

    30  Pages

  60. MA series

    16  Pages

  61. RH series

    16  Pages

  62. R series

    16  Pages

  63. PS series

    16  Pages

  64. L series

    41  Pages

  65. FUS20

    7  Pages

  66. GP series

    13  Pages

  67. VUS12 series

    2  Pages

  68. VUS21 series

    14  Pages

  69. VUS8-S series

    22  Pages

  70. JSD series

    10  Pages

  71. JK series

    10  Pages

  72. RVFUP series

    6  Pages

  73. VLF series

    16  Pages

  74. VFL series

    8  Pages

  75. VF series

    22  Pages

  76. ECV series

    8  Pages

  77. VPKE series

    4  Pages

  78. RPV06 Series

    8  Pages

  79. VZ Series

    34  Pages

  80. VX Series

    42  Pages

  81. VQ Series

    4  Pages

  82. VN Series

    40  Pages

  83. VK series

    53  Pages

  84. VJ Series

    34  Pages

  85. VG series

    21  Pages

  86. VRL series

    17  Pages

  87. VVV series

    11  Pages

  88. VLS series

    4  Pages

  89. VM | VC series

    28  Pages

  90. VY series

    24  Pages

  91. VB series

    11  Pages

  92. VH | VS series

    28  Pages

  93. VPHMP series

    12  Pages

  94. VYR series

    5  Pages

  95. HS series

    13  Pages

  96. HML series

    14  Pages

  97. VRG series

    18  Pages

  98. Dry Unit Series

    33  Pages

  99. VLM series

    12  Pages

  100. VSPE series

    5  Pages

  101. VT series

    21  Pages

  102. PB series

    13  Pages

  103. JSG series

    17  Pages

  104. pararel

    3  Pages

  105. fitting

    4  Pages

  106. BJSU series

    4  Pages

  107. SC

    15  Pages

  108. SPO

    12  Pages

  109. SP

    13  Pages

  110. RPV pump

    8  Pages

  111. Pre-set

    6  Pages

  112. Flange

    13  Pages

  113. HML

    14  Pages

  114. VYR

    5  Pages

  115. VPLFC

    17  Pages

  116. SVB

    172  Pages

  117. SVR

    39  Pages

  118. 8mm Sensor

    22  Pages

  119. Vacuum Filter

    28  Pages

  120. Fall Prevention

    18  Pages

  121. Vacuum Pen

    21  Pages

  122. cylinder

    22  Pages

  123. FDAbellows

    6  Pages

  124. Oval

    80  Pages

  125. sponge

    50  Pages

  126. mark-free

    34  Pages

  127. flat

    42  Pages

  128. Ultrathin

    34  Pages

  129. packaging bag

    13  Pages

  130. multi-bellow

    46  Pages

  131. bellows pad

    74  Pages

  132. Skid proof pad

    42  Pages

  133. soft bellow pad

    60  Pages

  134. soft pad

    66  Pages

  135. VRL

    17  Pages

  136. VZ

    34  Pages

  137. VX

    42  Pages

  138. VVV

    11  Pages

  139. VQ

    42  Pages

  140. VN

    40  Pages

  141. VLS

    4  Pages

  142. VLM

    12  Pages

  143. VK

    53  Pages

  144. VJ

    34  Pages

  145. VG

    21  Pages

  146. Vacuum Tube

    12  Pages

  147. Tube Cutter

    12  Pages

  148. Insert Ring

    12  Pages

  149. UL series

    12  Pages

  150. K series

    30  Pages

  151. Color Cap

    12  Pages

  152. Vacduum gripper

    18  Pages

  153. SSNC series

    13  Pages

  154. SJSC series

    24  Pages

  155. KJSC series

    17  Pages

  156. Silencer Series

    13  Pages

  157. Check Valve

    4  Pages

  158. JSG

    17  Pages

  159. GENERAL

    106  Pages

  160. Change Valve

    11  Pages

  161. SVA21 Series

    21  Pages

  162. P Series

    71  Pages

  163. SVA20 Series

    43  Pages

  164. BJSU series

    6  Pages

  165. NP68-01e

    17  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.