Group: 株式会社日本ピスコ
Catalog excerpts
SUS316 Equivalent Ball Valve chemical and mixed gases Option for10 series - compact body Fitting attached type … SUS316 Push-in fitting designed for 10 series Handle Option … Butterfly handle for Space Feature 3 piece structure/Full bore 3 piece structure ⇨ Easy maintenance by retightening nuts ! Max service pressure 1000psi (6.9MPa) ⇨ Wide Ball Valve feature SUS316 equivalent is used for liquid contacting part ※) SUS316 or CF8M The stem does not come off Structure preventing stem fr
Open the catalog to page 1Model Designation (Example) ③. Female thread size Code Size *Rc stands for BSPP female thread Code 10 Construction 1 piece, reduced bore 30 3 pieces, full bore ①. Stainless Steel Ball Valve SUS316 equivalent Option for 10 series Ball Valve ■ SUS316 equivalent Ball Valve comes with SUS316 Push-in Fitting models ※)Fittings and a valve are packaged separately in a box. Fittings should be installed by yourself. ②. Construction Code Construction 10 1 piece, reduced bore ①. SUS316 equivalent Ball Valve comes with SUS316 Push-in Fitting models ■ SUS316 Push-in Fitting for SUS316 equivalent Ball...
Open the catalog to page 2Specification Fluid medium Max. operating pressure *2) ( Air, Inert gas such as Nitrogen/ Helium (no toxic), Water/ Liquid(*1), Other(*1) NSBVF10 model : 800psi (5.5MPa) at temp. range -20~170°F (-29~77°C) NSBVF30 model : 1000psi (6.9MPa) at temp. range -20~100°F (-29~38°C) -29.8 in.Hg (-101kPa) -20~450 °F (-29 ~ + 232°C) (No Freezing of liquid) Max. Vacuum Operating temp. range (*2) ⚠ Warnings *1. Conditionswhen fluid medium is liquid or chemical. 1. Surge pressure must be controlled lower than maximum operating pressure when using with water and other liquids. 2. The specification above...
Open the catalog to page 3SUS316 equivalent - Ball Valve Dimensions 3-piece construction, Full bore (30 series) E2 1-piece construction, Reduced bore (10 series) SUS316 equivalent 10 series models with SUS316 push-in fittings ※) The dimensions of E1 and E2 of with fittings being installed.
Open the catalog to page 4Butterfly lever for SUS316 equivalent Ball Valve 10 series models B2 E2 SUS316 fitting for SUS316 equivalent 10 series models
Open the catalog to page 5Safety instruction manual Warnings 1.When the fluid medium is chemicals, solvents or mixed gases, check the chemical resistance before using the products. Damage or leakage may occur to the valve upon the usage. 2.Do not use the valve in applications that cause shaking or shocking. Damage or leakage may occur to the valve upon usage. 3.Do not use the products in environments that have vibration or shocking. Damage or leakage may occur to the valve upon usage. 4.Use soapy water or any other method to check for leakage before use. 5.After installation, carry out maintenance and leakage...
Open the catalog to page 6Transportation • Storage ・Turn the valve handle to the fully open position when transport or store otherwise it may lead to ball seat deformation. ・Store the valve indoor, avoiding dust and foreign matter. ・To prevent from dust and foreign mater, do not unwrap packaging before installation. Installation ・Before installation, use air blow or water to clean valve internal. ・IN/OUT flow can be connected to both side of valve. Choose side which is easy to install and operate. ・Consider the load from the piping when installing valve. ・Follow the tightening torque for tube fitting. ・Consider...
Open the catalog to page 7SUS316 equivalent - Ball Valve Open and Close ・Turn the handle 90° counterclockwise (Open) to open the valve and turn 90° clockwise (Shut) to close the valve. ■NSBVF10 Maintenance 1.After the installation, carry out regular inspection and maintenance periodically, considering environment including use frequency, temperature, fluid flow rate, pressure, fluid medium, etc 2.Periodically use soapy water or leakage checker to ensure there is no leakage. 3.If leakage occurred or packing worn out, retighten handle nut (for NSBVF10), gland nut and flange bolt/nut (for NSBVF30). 4.Retighten the nut...
Open the catalog to page 8All NIHON PISCO CO. catalogs and technical brochures
-
CTB series
1 Pages
-
FUS8 series
3 Pages
-
31 & 32 Series
20 Pages
-
Vacuum Pad Soft Series
86 Pages
-
VP series
106 Pages
-
CHA series
8 Pages
-
Gripper Series
15 Pages
-
SVB Series
50 Pages
-
SVA series
13 Pages
-
SVR series
31 Pages
-
Ball Valve SUS304 series
8 Pages
-
BV series
8 Pages
-
HV series
5 Pages
-
Cable clamp & Dividing sheet
8 Pages
-
Plarailchain SC
15 Pages
-
Plarailchain SPO
12 Pages
-
Plarailchain SP
14 Pages
-
HPO
12 Pages
-
HPU
12 Pages
-
PJN series
15 Pages
-
KJNC series
15 Pages
-
SSJS series
6 Pages
-
Flow Control Valve PP Series
12 Pages
-
Stainless SUS316
13 Pages
-
UE series
12 Pages
-
FB series
1 Pages
-
CTA series
1 Pages
-
SFTN series
2 Pages
-
SET series
1 Pages
-
SFT series
14 Pages
-
ULF series
12 Pages
-
UCQ series
2 Pages
-
UQ series
12 Pages
-
NB series
12 Pages
-
NA series
12 Pages
-
UD series
12 Pages
-
UBS series
12 Pages
-
UBT series
12 Pages
-
UC series
1 Pages
-
UB series
12 Pages
-
AK/AS series
26 Pages
-
NK series
18 Pages
-
Brass Series
30 Pages
-
V-0 series
27 Pages
-
EG Series
27 Pages
-
PP Fitting series
12 Pages
-
PP Series
26 Pages
-
AP series
18 Pages
-
SL series
16 Pages
-
P-SUS series
33 Pages
-
NS series
24 Pages
-
SSP series
8 Pages
-
ATS series
6 Pages
-
Air Filter
20 Pages
-
Combination Unit Series
25 Pages
-
SFU series
9 Pages
-
JP series
15 Pages
-
ET series
11 Pages
-
EQ series
19 Pages
-
CVLU series
21 Pages
-
CV series
24 Pages
-
JN series
25 Pages
-
Speed Controller Constant Flow
15 Pages
-
JSD series
10 Pages
-
JS Low-Flow series
17 Pages
-
JSC series
13 Pages
-
JS series
30 Pages
-
Miniature Pressure Regulator
12 Pages
-
MA series
16 Pages
-
RH series
16 Pages
-
R series
16 Pages
-
PS series
16 Pages
-
L series
41 Pages
-
FUS20
7 Pages
-
Small Flow Sensor FUS8 Sries
3 Pages
-
GP series
13 Pages
-
VUS-32. SEU-32 Series
1 Pages
-
Small Pressure Sensor 11-series
24 Pages
-
VUS12 series
2 Pages
-
VUS21 series
14 Pages
-
VUS8-S series
22 Pages
-
JSD series
10 Pages
-
Orifice Fitting Series
6 Pages
-
JK series
10 Pages
-
RVFUP series
6 Pages
-
VLF series
16 Pages
-
VFL series
8 Pages
-
VF series
22 Pages
-
ECV series
8 Pages
-
VPLFC, VPLFD series
17 Pages
-
VPKE series
4 Pages
-
RPV06 Series
8 Pages
-
VZ Series
34 Pages
-
VX Series
42 Pages
-
VQ Series
4 Pages
-
VN Series
40 Pages
-
VK series
53 Pages
-
VJ Series
34 Pages
-
VG series
21 Pages
-
VRL series
17 Pages
-
VVV series
11 Pages
-
VLS series
4 Pages
-
VM | VC series
28 Pages
-
VY series
24 Pages
-
VB series
11 Pages
-
VH | VS series
28 Pages
-
VPHMP series
12 Pages
-
VYR series
5 Pages
-
HS series
13 Pages
-
HML series
14 Pages
-
VRG series
18 Pages
-
Dry Unit Series
33 Pages
-
Fiber Membrane Air Dryer
12 Pages
-
VLM series
12 Pages
-
VSPE series
5 Pages
-
VT series
21 Pages
-
PB series
13 Pages
-
JSG series
17 Pages
-
pararel
3 Pages
-
fitting
4 Pages
-
BJSU series
4 Pages
-
SC
15 Pages
-
SPO
12 Pages
-
SP
13 Pages
-
RPV pump
8 Pages
-
Pre-set
6 Pages
-
Stainless Steel Ball Valve
8 Pages
-
SUS316 Flow Control Valve
6 Pages
-
Flange
13 Pages
-
HML
14 Pages
-
End of Arm Vacuum Gripper
12 Pages
-
VYR
5 Pages
-
EOAT VRG | VMG series
18 Pages
-
VPLFC
17 Pages
-
SVB
172 Pages
-
SVR
39 Pages
-
8mm Sensor
22 Pages
-
Vacuum Filter
28 Pages
-
Fall Prevention
18 Pages
-
Vacuum Pen
21 Pages
-
Push-Rod Release
4 Pages
-
cylinder
22 Pages
-
FDAbellows
6 Pages
-
Oval
80 Pages
-
sponge
50 Pages
-
mark-free
34 Pages
-
flat
42 Pages
-
Ultrathin
34 Pages
-
packaging bag
13 Pages
-
multi-bellow
46 Pages
-
bellows pad
74 Pages
-
Skid proof pad
42 Pages
-
soft bellow pad
60 Pages
-
soft pad
66 Pages
-
VRL
17 Pages
-
VH VS VC VUM VU VY VB
336 Pages
-
VZ
34 Pages
-
VX
42 Pages
-
VVV
11 Pages
-
VQ
42 Pages
-
VN
40 Pages
-
VLS
4 Pages
-
VLM
12 Pages
-
VK
53 Pages
-
VJ
34 Pages
-
VG
21 Pages
-
Vacuum Tube
12 Pages
-
Twin Coiling
12 Pages
-
Tube Cutter
12 Pages
-
Polyurethane Tube
12 Pages
-
Nylon Tube Series
12 Pages
-
Multi-core Planar Tube
12 Pages
-
Low-Friction Polyurethane Tube
12 Pages
-
Insert Ring
12 Pages
-
Fluororesin (PFA) Tube
14 Pages
-
UL series
12 Pages
-
Anti-spatter Tube
12 Pages
-
Tube Fitting PP Series
26 Pages
-
Tube Fitting Mini Series
41 Pages
-
Tube Fitting Chemical Series
18 Pages
-
K series
30 Pages
-
Stop Fitting Series
16 Pages
-
Rotary Joint Series
16 Pages
-
Multi-Circuit Rotary Block
12 Pages
-
Minimal Fitting Series
20 Pages
-
Main Block Series
24 Pages
-
Light Coupling Series
24 Pages
-
High Rotary Joint Series
16 Pages
-
Connector Series
16 Pages
-
Color Cap
12 Pages
-
Brass Compression Fitting Series
18 Pages
-
2-Circuit Junction Block Series
16 Pages
-
Vacuum EOAT Kit HML
14 Pages
-
Vacduum gripper
18 Pages
-
Mounting Flange for EOAT.pdf
13 Pages
-
SSNC series
13 Pages
-
SJSC series
24 Pages
-
Speed Controller Series
32 Pages
-
Speed Controller PP Series
17 Pages
-
Speed Controller Low Flow
17 Pages
-
Speed Controller High Flow
13 Pages
-
Speed Controller Brass Series
15 Pages
-
KJSC series
17 Pages
-
Silencer Series
13 Pages
-
Quick Exhaust Valve Series
19 Pages
-
Pressure Gauge Series
13 Pages
-
Miniture quick-exhaust
17 Pages
-
Fixed Orifice Joint Series
22 Pages
-
Check Valve
4 Pages
-
SUS304_Ball Valve Series
8 Pages
-
Parallel Gripper
6 Pages
-
JSG
17 Pages
-
GENERAL
106 Pages
-
Mechanical Valve Series
19 Pages
-
Ball Valve Series
19 Pages
-
Stainless Steel ball valve
6 Pages
-
Hand Valve Series
15 Pages
-
Change Valve
11 Pages
-
SVA21 Series
21 Pages
-
P Series
71 Pages
-
SVA20 Series
43 Pages
-
RegulatorPL031821m
12 Pages
-
BJSU series
6 Pages
-
NP68-01e
17 Pages