Group: 株式会社日本ピスコ
Catalog excerpts
Tamper-Proof Family Push-In Fitting Type Flow Control Valve for Constant Flow Rate Preset / Orifice Flow Control Valve ● ● Factory Preset Actuator Speed Preset Flow Rate by an orifice restrictor No-adjustable constant flow ● Selectable from 20 types of Orifice Bore (If the selection is difficult, contact us for support.)
Open the catalog to page 1Preset / Orifice Flow Control Valve ■ Model Designation (Example) JK Preset / Orifice Flow Control Valve Inch Hex. ④ Control direction ③ Thread size inch size ③ Thread size Thread size Straight thread (Special-Made) Taper pipe thread ※Theunitofwrenchsizeisinch(thecodesuffixis“U”). 10-32UNF and M5 thread are not standard for the series. Please ask us for available models. R thread is same as BSPT ④ Control direction Code Control direction Meter-out (Exhasut) Meter-in (Supply) ■ Air from thread side is controlled. Air from ■ Air from tube side is controlled. Air from tube side is not...
Open the catalog to page 2■ Specifications Fluid medium Operating pressure range Check valve cracking pressure Operating temp. range ■ Construction (Straight: JKC) Symbol Tubing Release ring (POM) Guide ring (Nickel-plated brass) Lock-claws (Stainless steel) Elastic sleeve (NBR) Metallic body (Nickel-plated brass) Orifice Tube End Sealock - coating ■ Standard Size List Connection: Thread ⇔ Tube Type JKC Straight 10-32UNF thread and M5 thread are not as standard. Please ask us for availabilities. Detailed Safety Instructions Before “Safety Instruction Manual” and “Common Safety Instructions for Controllers” Caution...
Open the catalog to page 3※ Specify "A" for Meter-out (Exhaust) control or "B" for Meter-in (Supply) control in ④ and orifice diameter from the following table in ⑤ ※ Orifice size 0 .1mm and 0 .2mm is available only for tubing O.D. 5/32" and 4mm "L" is reference values for height dimensions after tightening the thread Ask us availability for JKC5/32-U10 - 10-32UNF thread model ※ Specify "A" for Meter-out (Exhaust) control or "B" for Meter-in (Supply) control in ④ and orifice diameter from the following table in ⑤ ※ Orifice size 0 .1mm and 0 .2mm is available only for tubing O.D. 5/32" and 4mm "L" is reference values...
Open the catalog to page 4Controller Series Flow Characteristics (reference only) [Control Flow] [Free Flow]
Open the catalog to page 5Tube O.D. Model code øD JKC4-01 □□ JKC6-01 □□ JKC6-02□□ JKC8-01 □□ JKC8-02□□ Free flow effective area Weight CAD (mm2) (g) file name ※ 1. “L” is a reference value for height dimension after tightening taper thread. ※ 2. Left □ in Model code / Replaced with ”A” for Meter-out (Exhaust), “B” for Meter-in (Supply). Right □ in Model code / Replaced with orifice bore size selected from the following table. Tube O.D. Model code øD JKL4-01 □□ JKL6-01 □□ JKL6-02 □□ JKL8-01 □□ JKL8-02 □□ Hex. Free flow effective area Weight CAD (mm2) (g) file name H 10 ※ 1. “L” is a reference value for height...
Open the catalog to page 6■ How to select orifice bore ■ Select orifice bore by the following method, when controlling cylinder speed with Speed Controller Constant Flow. ① Use the following calculation formula and find an necessary air flow rate in order to control cylinder at desired speed. (Calculation to find air flow rate) P + 0.1013 D2 × L Q = 4.7 × 10-5 ×────×────── t 0.1013 Q = Air flow rate (l/min(ANR)) D = Cylinder tube I.D.(mm) L = Cylinder stroke (mm) t = One-way stroke time (sec) P = Operating pressure (MPa) ② Use the chart of Flow Characteristic. Select 2 or 3 orifice bores which are closer...
Open the catalog to page 7Flow rate (l/min(ANR)) Flow rate (l/min(ANR)) Flow rate (l/min(ANR)) Free flow
Open the catalog to page 8Air flow rate (l/min(ANR)) [Chart 2.] Chart for obtaining air flow rate of air cylinder 20 50 Cylinder speed (mm/sec)
Open the catalog to page 9Common Safety Instructions for Controllers Before selecting or using PISCO products, read the following instructions. Read the detailed instructions for individual series as well as the instructions below. Warning 1. Some products have an air direction to control. Make sure to distinguish the direction by marking on the products. Installing the product with the wrong direction may cause personal injury or property damage. 2. Avoid any load on PISCO products such as a tensile strength, twisting, bending, dropping and excessive impacts. These may cause damage to the products. 3. Locknut needs...
Open the catalog to page 10All NIHON PISCO CO. catalogs and technical brochures
-
CTB series
1 Pages
-
FUS8 series
3 Pages
-
31 & 32 Series
20 Pages
-
Vacuum Pad Soft Series
86 Pages
-
VP series
106 Pages
-
CHA series
8 Pages
-
Gripper Series
15 Pages
-
SVB Series
50 Pages
-
SVA series
13 Pages
-
SVR series
31 Pages
-
NSB series
8 Pages
-
Ball Valve SUS304 series
8 Pages
-
BV series
8 Pages
-
HV series
5 Pages
-
Cable clamp & Dividing sheet
8 Pages
-
Plarailchain SC
15 Pages
-
Plarailchain SPO
12 Pages
-
Plarailchain SP
14 Pages
-
HPO
12 Pages
-
HPU
12 Pages
-
PJN series
15 Pages
-
KJNC series
15 Pages
-
SSJS series
6 Pages
-
Flow Control Valve PP Series
12 Pages
-
Stainless SUS316
13 Pages
-
UE series
12 Pages
-
FB series
1 Pages
-
CTA series
1 Pages
-
SFTN series
2 Pages
-
SET series
1 Pages
-
SFT series
14 Pages
-
ULF series
12 Pages
-
UCQ series
2 Pages
-
UQ series
12 Pages
-
NB series
12 Pages
-
NA series
12 Pages
-
UD series
12 Pages
-
UBS series
12 Pages
-
UBT series
12 Pages
-
UC series
1 Pages
-
UB series
12 Pages
-
AK/AS series
26 Pages
-
NK series
18 Pages
-
Brass Series
30 Pages
-
V-0 series
27 Pages
-
EG Series
27 Pages
-
PP Fitting series
12 Pages
-
PP Series
26 Pages
-
AP series
18 Pages
-
SL series
16 Pages
-
P-SUS series
33 Pages
-
NS series
24 Pages
-
SSP series
8 Pages
-
ATS series
6 Pages
-
Air Filter
20 Pages
-
Combination Unit Series
25 Pages
-
SFU series
9 Pages
-
JP series
15 Pages
-
ET series
11 Pages
-
EQ series
19 Pages
-
CVLU series
21 Pages
-
CV series
24 Pages
-
JN series
25 Pages
-
Speed Controller Constant Flow
15 Pages
-
JSD series
10 Pages
-
JS Low-Flow series
17 Pages
-
JSC series
13 Pages
-
JS series
30 Pages
-
Miniature Pressure Regulator
12 Pages
-
MA series
16 Pages
-
RH series
16 Pages
-
R series
16 Pages
-
PS series
16 Pages
-
L series
41 Pages
-
FUS20
7 Pages
-
Small Flow Sensor FUS8 Sries
3 Pages
-
GP series
13 Pages
-
VUS-32. SEU-32 Series
1 Pages
-
Small Pressure Sensor 11-series
24 Pages
-
VUS12 series
2 Pages
-
VUS21 series
14 Pages
-
VUS8-S series
22 Pages
-
JSD series
10 Pages
-
Orifice Fitting Series
6 Pages
-
RVFUP series
6 Pages
-
VLF series
16 Pages
-
VFL series
8 Pages
-
VF series
22 Pages
-
ECV series
8 Pages
-
VPLFC, VPLFD series
17 Pages
-
VPKE series
4 Pages
-
RPV06 Series
8 Pages
-
VZ Series
34 Pages
-
VX Series
42 Pages
-
VQ Series
4 Pages
-
VN Series
40 Pages
-
VK series
53 Pages
-
VJ Series
34 Pages
-
VG series
21 Pages
-
VRL series
17 Pages
-
VVV series
11 Pages
-
VLS series
4 Pages
-
VM | VC series
28 Pages
-
VY series
24 Pages
-
VB series
11 Pages
-
VH | VS series
28 Pages
-
VPHMP series
12 Pages
-
VYR series
5 Pages
-
HS series
13 Pages
-
HML series
14 Pages
-
VRG series
18 Pages
-
Dry Unit Series
33 Pages
-
Fiber Membrane Air Dryer
12 Pages
-
VLM series
12 Pages
-
VSPE series
5 Pages
-
VT series
21 Pages
-
PB series
13 Pages
-
JSG series
17 Pages
-
pararel
3 Pages
-
fitting
4 Pages
-
BJSU series
4 Pages
-
SC
15 Pages
-
SPO
12 Pages
-
SP
13 Pages
-
RPV pump
8 Pages
-
Pre-set
6 Pages
-
Stainless Steel Ball Valve
8 Pages
-
SUS316 Flow Control Valve
6 Pages
-
Flange
13 Pages
-
HML
14 Pages
-
End of Arm Vacuum Gripper
12 Pages
-
VYR
5 Pages
-
EOAT VRG | VMG series
18 Pages
-
VPLFC
17 Pages
-
SVB
172 Pages
-
SVR
39 Pages
-
8mm Sensor
22 Pages
-
Vacuum Filter
28 Pages
-
Fall Prevention
18 Pages
-
Vacuum Pen
21 Pages
-
Push-Rod Release
4 Pages
-
cylinder
22 Pages
-
FDAbellows
6 Pages
-
Oval
80 Pages
-
sponge
50 Pages
-
mark-free
34 Pages
-
flat
42 Pages
-
Ultrathin
34 Pages
-
packaging bag
13 Pages
-
multi-bellow
46 Pages
-
bellows pad
74 Pages
-
Skid proof pad
42 Pages
-
soft bellow pad
60 Pages
-
soft pad
66 Pages
-
VRL
17 Pages
-
VH VS VC VUM VU VY VB
336 Pages
-
VZ
34 Pages
-
VX
42 Pages
-
VVV
11 Pages
-
VQ
42 Pages
-
VN
40 Pages
-
VLS
4 Pages
-
VLM
12 Pages
-
VK
53 Pages
-
VJ
34 Pages
-
VG
21 Pages
-
Vacuum Tube
12 Pages
-
Twin Coiling
12 Pages
-
Tube Cutter
12 Pages
-
Polyurethane Tube
12 Pages
-
Nylon Tube Series
12 Pages
-
Multi-core Planar Tube
12 Pages
-
Low-Friction Polyurethane Tube
12 Pages
-
Insert Ring
12 Pages
-
Fluororesin (PFA) Tube
14 Pages
-
UL series
12 Pages
-
Anti-spatter Tube
12 Pages
-
Tube Fitting PP Series
26 Pages
-
Tube Fitting Mini Series
41 Pages
-
Tube Fitting Chemical Series
18 Pages
-
K series
30 Pages
-
Stop Fitting Series
16 Pages
-
Rotary Joint Series
16 Pages
-
Multi-Circuit Rotary Block
12 Pages
-
Minimal Fitting Series
20 Pages
-
Main Block Series
24 Pages
-
Light Coupling Series
24 Pages
-
High Rotary Joint Series
16 Pages
-
Connector Series
16 Pages
-
Color Cap
12 Pages
-
Brass Compression Fitting Series
18 Pages
-
2-Circuit Junction Block Series
16 Pages
-
Vacuum EOAT Kit HML
14 Pages
-
Vacduum gripper
18 Pages
-
Mounting Flange for EOAT.pdf
13 Pages
-
SSNC series
13 Pages
-
SJSC series
24 Pages
-
Speed Controller Series
32 Pages
-
Speed Controller PP Series
17 Pages
-
Speed Controller Low Flow
17 Pages
-
Speed Controller High Flow
13 Pages
-
Speed Controller Brass Series
15 Pages
-
KJSC series
17 Pages
-
Silencer Series
13 Pages
-
Quick Exhaust Valve Series
19 Pages
-
Pressure Gauge Series
13 Pages
-
Miniture quick-exhaust
17 Pages
-
Fixed Orifice Joint Series
22 Pages
-
Check Valve
4 Pages
-
SUS304_Ball Valve Series
8 Pages
-
Parallel Gripper
6 Pages
-
JSG
17 Pages
-
GENERAL
106 Pages
-
Mechanical Valve Series
19 Pages
-
Ball Valve Series
19 Pages
-
Stainless Steel ball valve
6 Pages
-
Hand Valve Series
15 Pages
-
Change Valve
11 Pages
-
SVA21 Series
21 Pages
-
P Series
71 Pages
-
SVA20 Series
43 Pages
-
RegulatorPL031821m
12 Pages
-
BJSU series
6 Pages
-
NP68-01e
17 Pages