cad

Fiber Membrane Air Dryer
12Pages

{{requestButtons}}

Catalog excerpts

Fiber Membrane Air Dryer - 1

Hollow Fiber Membrane Air Dryer with Built-in Push-In Fitting Fiber Membrane Filter Type Dryer which does require no power supply. Higher performance than a refrigeration air dryer. is removed through Hollow Fiber Membrane with no drain. ● No heat discharge nor vibration. Compact and lightweight body makes it portable and space saving. ● Easy ● Purging air volume is adjustable. ● Push-In

Open the catalog to page 1
Fiber Membrane Air Dryer - 2

Membrane Dryer ■ Model Designation (Example) DMM 100 ⑤ Operating Flow Rate (Outlet Port) ③ Tubing Dia. or Female Thread Dryer (Plastic Body) Dryer (Metal Body) Dryer (Union Straight) Dryer (Flexible Type) Code Flow Rate SFCM ③ Tube Dia. / Female Taper Thread (DMM100 and 301 only) 00 Code Female thread  In case INCH size tubing connection is needed; Rc1/4 - specify PC1/4-02 (straight 1/4" O.D.), PC3/8-02 (straight 3/8" O.D.), PL1/4-02 (elbow 1/4" O.D.) or PL3/8-02 (elbow 3/8" O.D.) Rc3/8 - specify PC3/8-03 (straight 3/8" O.D.), PC1/2-03 (straight 1/2" O.D.), PL3/8-03 (elbow 3/8" O.D.) or...

Open the catalog to page 2
Fiber Membrane Air Dryer - 3

■ Specifications Fluid Medium Operating Pressure Range Fluid Medium Temp. Inside of hollow fiber:43 ~ 123psi (0.3 ~ 0.85MPa) Outside of hollow fiber:0 ~ 7.25psi (0 ~ 0.05MPa) 32~104°F ( 0 ~ 40℃ (No freezing)) Operating Temp. Range * When fluid medium other than air is used, contact us for details before using. ■ Basic Performance(For 3.53SCFM (100l/min(ANR))) ■ Inlet Port Air Pressure Air Temp. Water Vapor Amount Purge Rate ■ Outlet Port Air 3.53SCFM (100 l/min(ANR)) -13°F (-25℃) or less (Atmospheric pressure) ■ Mechanism of Dehumidification ■ Only vapor in compressed air flows inside the...

Open the catalog to page 3
Fiber Membrane Air Dryer - 4

Membrane Dryer ■ Piping Example ■ neumatic System with Oil Mist P * Place a Dry Unit with Mist Filter for a pneumatic system containing oil mist. ■ neumatic System without Oil Mist P * Make sure to place a filter for a pneumatic system generating water drop. ■ Relation between Use Condition and Dry Level Refer to the following chart when you select Fiber Dry Series. Low High Supplied Air Pressure Low High Supplied Air Temp. Small Large Supplied Air Amount ■ Classification by Flow Rate Flow Rate (l/min(ANR)) 500 Small Large Purging

Open the catalog to page 4
Fiber Membrane Air Dryer - 5

Detailed Safety Instructions Before using PISCO products, be sure to read “Safety Instructions” and “Safety Instruction Manual” and “Common Safety Instructions for Fiber Dry Series and Dry Unit Series” . 1. Be sure to turn Purging Flow Adjustment Dial to the correct direction as the marking on the body shows. Incorrect way can damage the product. ■ Adjustment Method of Purging Flow Purging Flow Adjustment Dial ・When the amount of Purging Flow is large, turn the dial clockwise so that purging flow decreases. Turn the dial counterclockwise to increase the purging flow. But the temp. of dew...

Open the catalog to page 5
Fiber Membrane Air Dryer - 6

Membrane Dryer DMM Metal Body Dryer 100 Tube O.D. Model Code øD Weight CAD (g) file name Dehumidifying Performance Chart (example) Purging Flow Chart Achieved Dew Point (At atmospheric pressure) (℃) Purging Flow (l/min(ANR)) Purging Hole DMM Resin Body Dryer 301 Unit:mm Tube O.D. Model Code øD DMM301-6 DMM301-8 DMM301-10 DMM301-12 DMM301-16 DMM301-00 Purging Flow Adjustment Dial Weight CAD (g) file name Dehumidifying Performance Chart (example) Purging Flow Chart Achieved Dew Point (At atmospheric pressure) (℃) Purging Flow (l/min(ANR)) Purging Hole 100 150 200 250 Operating Flow Rate...

Open the catalog to page 6
Fiber Membrane Air Dryer - 7

DMM Resin Body Dryer Unit:mm Tube O.D. Model Code øD Weight CAD (g) file name 65 * Purging Flow Adjustment is not available for DMM040. Refer to the following table to select the best item. Operating Flow Rate (Outlet Port) Dehumidifying Performance Chart (example) Purging Flow Chart Purging Flow(l/min(ANR)) Achieved Dew Point (At atmospheric pressure) (℃) DMP Resin Body Dryer 100 Tube O.D. Model Code øD DMP100-4 DMP100-6 DMP100-8 DMP100-10 Weight CAD (g) file name Dehumidifying Performance Chart(example) FDT, DMP Purging Flow Chart Achieved Dew Point (At atmospheric pressure) (℃) Purging...

Open the catalog to page 7
Fiber Membrane Air Dryer - 8

Membrane Dryer FDT DMP Dryer and Filter Set 100 Manual Drain Tube O.D. Model Code L1 øD Auto Drain M5 Female Thread Drainage

Open the catalog to page 8
Fiber Membrane Air Dryer - 9

DMB Union Straight Dryer 100 Tube O.D. Model Code øD Weight CAD (g) file name Dehumidifying Performance Chart (example) Purging Flow Chart Achieved Dew Point (At atmospheric pressure) (℃) Purging Flow (l/min(ANR)) (Fixing hole for bracket) DMB Union Straight Dryer Unit:mm Model Code Dehumidifying Performance Chart (example) Purging Flow Chart Purging Flow (l/min(ANR)) Achieved Dew Point (At atmospheric pressure) (℃)

Open the catalog to page 9
Fiber Membrane Air Dryer - 10

Membrane Dryer DMF Flexible Type Dryer 040 526 Tube O.D. Model Code øD Dehumidifying Performance Chart (example) Purging Flow Chart Purging Flow (l/min(ANR)) Achieved Dew Point (At atmospheric pressure) (℃) Weight CAD E2 (g) file name ■ Fiber Dry Series Mounting Bracket ■ Use two fixing holes to install the product by M5 screws Push-In Fitting ■ Recommended Tube O.D.: Wide range of the O.D. ø4, 6, 8, 10, 12 and 16mm ■ When the Purging Flow is too much, it can be reduced b

Open the catalog to page 10
Fiber Membrane Air Dryer - 11

Visit "Dryer Unit" for combination with air filter, mist filter and regulator

Open the catalog to page 11
Fiber Membrane Air Dryer - 12

Common Safety Instructions for Fiber Dry Series and Dry Unit Series  Before selecting or using PISCO products, read the following instructions. Read the detailed instructions for individual series. Warning 1. When installing the dryer, provide adequate support and fix it securely. Looseness or dropping off of the dryer may cause injuries. 2. Do not use the dryer without the explosion-proof casing (bowl guard). If the bowl breaks, the pieces may fly apart to cause injuries. 3. Make sure to set the lock lever on the filter, mist filter and micromist filter to "lock" before using. Otherwise,...

Open the catalog to page 12

All NIHON PISCO CO. catalogs and technical brochures

  1. CTB series

    1 Pages

  2. FUS8 series

    3 Pages

  3. 31 & 32 Series

    20 Pages

  4. VP series

    106 Pages

  5. CHA series

    8 Pages

  6. Gripper Series

    15 Pages

  7. SVB Series

    50 Pages

  8. SVA series

    13 Pages

  9. SVR series

    31 Pages

  10. NSB series

    8 Pages

  11. BV series

    8 Pages

  12. HV series

    5 Pages

  13. HPO

    12 Pages

  14. HPU

    12 Pages

  15. PJN series

    15 Pages

  16. KJNC series

    15 Pages

  17. SSJS series

    6 Pages

  18. UE series

    12 Pages

  19. FB series

    1 Pages

  20. CTA series

    1 Pages

  21. SFTN series

    2 Pages

  22. SET series

    1 Pages

  23. SFT series

    14 Pages

  24. ULF series

    12 Pages

  25. UCQ series

    2 Pages

  26. UQ series

    12 Pages

  27. NB series

    12 Pages

  28. NA series

    12 Pages

  29. UD series

    12 Pages

  30. UBS series

    12 Pages

  31. UBT series

    12 Pages

  32. UC series

    1 Pages

  33. UB series

    12 Pages

  34. AK/AS series

    26 Pages

  35. NK series

    18 Pages

  36. Brass Series

    30 Pages

  37. V-0 series

    27 Pages

  38. EG Series

    27 Pages

  39. PP Series

    26 Pages

  40. AP series

    18 Pages

  41. SL series

    16 Pages

  42. P-SUS series

    33 Pages

  43. NS series

    24 Pages

  44. SSP series

    8 Pages

  45. ATS series

    6 Pages

  46. Air Filter

    20 Pages

  47. SFU series

    9 Pages

  48. JP series

    15 Pages

  49. ET series

    11 Pages

  50. EQ series

    19 Pages

  51. CVLU series

    21 Pages

  52. CV series

    24 Pages

  53. JN series

    25 Pages

  54. JSD series

    10 Pages

  55. JSC series

    13 Pages

  56. JS series

    30 Pages

  57. MA series

    16 Pages

  58. RH series

    16 Pages

  59. R series

    16 Pages

  60. PS series

    16 Pages

  61. L series

    41 Pages

  62. FUS20

    7 Pages

  63. GP series

    13 Pages

  64. VUS12 series

    2 Pages

  65. VUS21 series

    14 Pages

  66. VUS8-S series

    22 Pages

  67. JSD series

    10 Pages

  68. JK series

    10 Pages

  69. RVFUP series

    6 Pages

  70. VLF series

    16 Pages

  71. VFL series

    8 Pages

  72. VF series

    22 Pages

  73. ECV series

    8 Pages

  74. VPKE series

    4 Pages

  75. RPV06 Series

    8 Pages

  76. VZ Series

    34 Pages

  77. VX Series

    42 Pages

  78. VQ Series

    4 Pages

  79. VN Series

    40 Pages

  80. VK series

    53 Pages

  81. VJ Series

    34 Pages

  82. VG series

    21 Pages

  83. VRL series

    17 Pages

  84. VVV series

    11 Pages

  85. VLS series

    4 Pages

  86. VM | VC series

    28 Pages

  87. VY series

    24 Pages

  88. VB series

    11 Pages

  89. VH | VS series

    28 Pages

  90. VPHMP series

    12 Pages

  91. VYR series

    5 Pages

  92. HS series

    13 Pages

  93. HML series

    14 Pages

  94. VRG series

    18 Pages

  95. VLM series

    12 Pages

  96. VSPE series

    5 Pages

  97. VT series

    21 Pages

  98. PB series

    13 Pages

  99. JSG series

    17 Pages

  100. pararel

    3 Pages

  101. fitting

    4 Pages

  102. BJSU series

    4 Pages

  103. SC

    15 Pages

  104. SPO

    12 Pages

  105. SP

    13 Pages

  106. RPV pump

    8 Pages

  107. Pre-set

    6 Pages

  108. Flange

    13 Pages

  109. HML

    14 Pages

  110. VYR

    5 Pages

  111. VPLFC

    17 Pages

  112. SVB

    172 Pages

  113. SVR

    39 Pages

  114. 8mm Sensor

    22 Pages

  115. Vacuum Filter

    28 Pages

  116. Vacuum Pen

    21 Pages

  117. cylinder

    22 Pages

  118. FDAbellows

    6 Pages

  119. Oval

    80 Pages

  120. sponge

    50 Pages

  121. mark-free

    34 Pages

  122. flat

    42 Pages

  123. Ultrathin

    34 Pages

  124. packaging bag

    13 Pages

  125. multi-bellow

    46 Pages

  126. bellows pad

    74 Pages

  127. Skid proof pad

    42 Pages

  128. soft pad

    66 Pages

  129. VRL

    17 Pages

  130. VZ

    34 Pages

  131. VX

    42 Pages

  132. VVV

    11 Pages

  133. VQ

    42 Pages

  134. VN

    40 Pages

  135. VLS

    4 Pages

  136. VLM

    12 Pages

  137. VK

    53 Pages

  138. VJ

    34 Pages

  139. VG

    21 Pages

  140. Vacuum Tube

    12 Pages

  141. Twin Coiling

    12 Pages

  142. Tube Cutter

    12 Pages

  143. Insert Ring

    12 Pages

  144. UL series

    12 Pages

  145. K series

    30 Pages

  146. Color Cap

    12 Pages

  147. SSNC series

    13 Pages

  148. SJSC series

    24 Pages

  149. KJSC series

    17 Pages

  150. Check Valve

    4 Pages

  151. JSG

    17 Pages

  152. GENERAL

    106 Pages

  153. Change Valve

    11 Pages

  154. SVA21 Series

    21 Pages

  155. P Series

    71 Pages

  156. SVA20 Series

    43 Pages

  157. BJSU series

    6 Pages

  158. NP68-01e

    17 Pages