Dry Unit Series - 1

Hollow Fiber Membrane Type Air Drier Unit electric power supply is required. Air Filter, Mist Filter (Micromist Filter) and Regulator are integrated. type achieving direct connection to air source. Air Filter Mist Filter or Micromist Filter Gauge Option - Bourdon tube Compact Pressure Gauge Battery Operated Digital Display Gauge Dual LCD Display Pressure Sensor Swi

Open the catalog to page 1
Dry Unit Series - 2

Dry Unit ■ Model Designation (Example) FMDR ① Unit Type ③ Inlet-side Connection Port ④ Outlet-side Connection Port ① Unit Type Code Mist Filter Micromist Filter ② Flow Rate Code Flow Rate(l/min(ANR)) Table 1. Thread Size (Female) 100 Series (*For Rc thread (02 and 03), size of Inlet and Outlet Ports are same.) C6(e.g.):Fitting Size (Refer to Table 2) ④ Outlet Port (* Selectable for Fitting Size only) No Code:Same size as Inlet port C6(e.g.):Fitting Size (Refer to Table 2) ⑤ Drainage Cock Table 2. Thread Size of Push-In Fitting C Straight Type MD:Manual Drain Cock AD:Auto Drain Cock No...

Open the catalog to page 2
Dry Unit Series - 3

⑦ Pressure Gauge No entry:Bourdon tube pressure gauge L:No gauge G:Digital pressure gauge T2:Dual LCD digital pressure sensor(1 point SW +analog output(2m cable) ) ) T2C:Dual LCD digital pressure sensor(1point SW+analog output(M8, 4-pin male connector) T3:Dual LCD digital pressure sensor(2 points SW output(2m cable) ) T3C:Dual LCD digital pressure sensor(2 points SW output(M8, 4-pin male connector) ) T4:Dual LCD digital pressure sensor(NPN output, 2 points SW output+analog output) T4P:Dual LCD digital pressure sensor(PNP output, 2 points SW output+analog output) T5:Dual LCD digital pressure...

Open the catalog to page 3
Dry Unit Series - 4

Dry Unit ■ Calculation Method of Dehumidification Amount ● Conditions [Fig. 2] (Table of Saturated Vapor Amount) Temp. Vapor Amount Temp. Vapor Amount Dehumification amount is under the following condition. (ºC) (ºC) (g/m3) (g/m3) Compressed air of temp.: 20oC, humidity: 100%, pressure: -50 0.0617 0 4.85 0.7MPa is dehumidified up to dew point -25oC by an air dryer. ■ Example: Calculation Method of Atmospheric Dew Point (Temp.: 20oC, Humidity: 100%, Pressure: 0.7MPa)   [Fig. 1] Atmospheric Dew Point………- 8℃ Check the saturated vapor at -8oC and -25oC in the figure 1.   [Fig. 2]     Amount of...

Open the catalog to page 4
Dry Unit Series - 5

Relative Humidity (%) Air Temp. 25℃ Detailed Safety Instructions Before using PISCO products, be sure to read “Safety Instructions” and “Safety Instruction Manual” and Common Safety Instructions for Fiber Dry and Dry Unit”. Caution 1. Make sure to adjust the pressure of the regulator in the increasing direction and lock it by pressing the lock button after adjustment. 2. Air is exhauseted from the drain port until the supply pressure rises to 0.05MPa for Manual Drain Type and to 0.15Mpa for Auto Drain Type. During this time, the air will not stop coming out even if the drain knob is turned....

Open the catalog to page 5
Dry Unit Series - 6

Dry Unit ■ How to insert and disconnect 1. How to insert and disconnect tubes ① Tube installation For Dry Unit Series (Dry Unit Series with a Built-in Tube Fitting), insert a Push-In Fitting until it touches to the tube end which makes the lock-claws bite the tube to fix and the elastic sleeve seal around the tube. Refer to “2. Instructions for Tube Installation” under “Common Safety Instructions for Fittings” when installing a tube fitting. ② Tube disconnection The tube is disconnected by pushing the release-ring which releases the lock-claws. Make sure to stop air supply before the tube...

Open the catalog to page 6
Dry Unit Series - 7

Unit of Air Filter, Micromist Filter, Fiber Dry and Regulator with Bourdon Tube Pressure Gauge Unit of Air Filter, Mist Filter, Fiber Dry and Regulator with Bourdon Tube Pressure Gauge Purging Flow Adjustment Dial Manual Drain Cock Automatic Drain Cock Push-In Fitting Drainage Drainage Barb Fitting Weight (g) Port Dia.:02(Rc1/4) Port Dia.:03(Rc3/8) 1,593

Open the catalog to page 7
Dry Unit Series - 8

Dry Unit ■ 100 Series FMDR Unit of Air Filter, Micromist Filter, Fiber Dry and Regulator with Digital Pressure Gauge Unit of Air Filter, Mist Filter, Fiber Dry and Regulator with Digital Pressure Gauge Purging Flow Adjusting knob Digital Pressure Gauge:GPD ø7 Automatic Drain Cock Push-in type Fitting Manual Drain Cock Weight (g) Port Dia.:02(Rc1/4) Port Dia.:03(Rc3/8) 1,602 ※ 1. The dimension of 108.5mm is just for reference. ※ 2. Fill in ③ of model code with 02 for Rc1/4 thread or 03 for Rc3/8 thread. Fill in ⑥ with R only if the flow direction from right to left is needed. Otherwise leave...

Open the catalog to page 8
Dry Unit Series - 9

Unit of Air Filter, Micromist Filter, Fiber Dry and Regulator with Digital Pressure Gauge Unit of Air Filter, Mist Filter, Fiber Dry and Regulator with Digital Pressure Gauge Purging Flow Adjusting knob Cable length about 2000 (※2) : Digital Pressure Sensor Manual Drain Cock Barb Fitting Drainage Drainage For digital pressure sensor: SEU-31-N□ ( model codes come with T2□ and T3□) Push-in type Fitting Automatic Drain Cock For digital pressure sensor:SEU-32-□ (model codes come with T4□ and T5□) ●For model codes with T2 □ and T3 □ Weight (g) Port Dia.:02(Rc1/4) Port Dia.:03(Rc3/8) 1,638 Fill...

Open the catalog to page 9
Dry Unit Series - 10

Dry Unit ■ 100 Series FMDR Unit of Air Filter, Micromist Filter, Fiber Dry 100 and Regulator with No Gauge FBDR Unit of Air Filter, Mist Filter, Fiber Dry compliant and Regulator with No Gauge Purging Flow Adjustment Dial Manual Drain Cock Drainage Drainage Automatic Drain Cock Push-In Fitting Barb Fitting Weight (g) Port Dia:02(Rc1/4) Port Dia:03(Rc3/8) 1,556

Open the catalog to page 10
Dry Unit Series - 11

Micromist Filter and Fiber Dry Mist Filter and Fiber Dry Purging Flow Adjustment Dial Manual Drain Cock Automatic Drain Cock Push-In Fitting Barb Fitting

Open the catalog to page 11
Dry Unit Series - 12

Dry Unit ■ 100 Series FDR Unit of Air Filter, Fiber Dry and Regulator compliant with Bourdon Tube Pressure Gauge Manual Drain Cock Automatic Drain Cock Push-In Fitting Barb Fitting Purging Flow Adjustment Dial Weight (g) Port Dia.:02(Rc1/4) Port Dia.:03(Rc3/8) 1,246.5

Open the catalog to page 12
Dry Unit Series - 13

Unit of Air Filter, Fiber Dry and Regulator with Digital Pressure Gauge Purging Flow Adjusting knob Manual Drain Cock Drainage Barb Fitting Automatic Drain Cock Push-in type Fitting Digital Pressure Gauge:GPD Weight (g) Port Dia.:02(Rc1/4) Port Dia.:03(Rc3/8) 1,255 ※ 1. The dimension of 108.5mm is just for reference. ※ 2. Fill in ③ of model code with 02 for Rc1/4 thread or 03 for Rc3/8 thread. Fill in ⑥ with R only if the flow direction from right to left is needed. Otherwise leave it blank (standard flow direc

Open the catalog to page 13

All NIHON PISCO CO. catalogs and technical brochures

  1. CTB series

    1 Pages

  2. FUS8 series

    3 Pages

  3. 31 & 32 Series

    20 Pages

  4. VP series

    106 Pages

  5. CHA series

    8 Pages

  6. Gripper Series

    15 Pages

  7. SVB Series

    50 Pages

  8. SVA series

    13 Pages

  9. SVR series

    31 Pages

  10. NSB series

    8 Pages

  11. BV series

    8 Pages

  12. HV series

    5 Pages

  13. HPO

    12 Pages

  14. HPU

    12 Pages

  15. PJN series

    15 Pages

  16. KJNC series

    15 Pages

  17. SSJS series

    6 Pages

  18. UE series

    12 Pages

  19. FB series

    1 Pages

  20. CTA series

    1 Pages

  21. SFTN series

    2 Pages

  22. SET series

    1 Pages

  23. SFT series

    14 Pages

  24. ULF series

    12 Pages

  25. UCQ series

    2 Pages

  26. UQ series

    12 Pages

  27. NB series

    12 Pages

  28. NA series

    12 Pages

  29. UD series

    12 Pages

  30. UBS series

    12 Pages

  31. UBT series

    12 Pages

  32. UC series

    1 Pages

  33. UB series

    12 Pages

  34. AK/AS series

    26 Pages

  35. NK series

    18 Pages

  36. Brass Series

    30 Pages

  37. V-0 series

    27 Pages

  38. EG Series

    27 Pages

  39. PP Series

    26 Pages

  40. AP series

    18 Pages

  41. SL series

    16 Pages

  42. P-SUS series

    33 Pages

  43. NS series

    24 Pages

  44. SSP series

    8 Pages

  45. ATS series

    6 Pages

  46. Air Filter

    20 Pages

  47. SFU series

    9 Pages

  48. JP series

    15 Pages

  49. ET series

    11 Pages

  50. EQ series

    19 Pages

  51. CVLU series

    21 Pages

  52. CV series

    24 Pages

  53. JN series

    25 Pages

  54. JSD series

    10 Pages

  55. JSC series

    13 Pages

  56. JS series

    30 Pages

  57. MA series

    16 Pages

  58. RH series

    16 Pages

  59. R series

    16 Pages

  60. PS series

    16 Pages

  61. L series

    41 Pages

  62. FUS20

    7 Pages

  63. GP series

    13 Pages

  64. VUS12 series

    2 Pages

  65. VUS21 series

    14 Pages

  66. VUS8-S series

    22 Pages

  67. JSD series

    10 Pages

  68. JK series

    10 Pages

  69. RVFUP series

    6 Pages

  70. VLF series

    16 Pages

  71. VFL series

    8 Pages

  72. VF series

    22 Pages

  73. ECV series

    8 Pages

  74. VPKE series

    4 Pages

  75. RPV06 Series

    8 Pages

  76. VZ Series

    34 Pages

  77. VX Series

    42 Pages

  78. VQ Series

    4 Pages

  79. VN Series

    40 Pages

  80. VK series

    53 Pages

  81. VJ Series

    34 Pages

  82. VG series

    21 Pages

  83. VRL series

    17 Pages

  84. VVV series

    11 Pages

  85. VLS series

    4 Pages

  86. VM | VC series

    28 Pages

  87. VY series

    24 Pages

  88. VB series

    11 Pages

  89. VH | VS series

    28 Pages

  90. VPHMP series

    12 Pages

  91. VYR series

    5 Pages

  92. HS series

    13 Pages

  93. HML series

    14 Pages

  94. VRG series

    18 Pages

  95. VLM series

    12 Pages

  96. VSPE series

    5 Pages

  97. VT series

    21 Pages

  98. PB series

    13 Pages

  99. JSG series

    17 Pages

  100. pararel

    3 Pages

  101. fitting

    4 Pages

  102. BJSU series

    4 Pages

  103. SC

    15 Pages

  104. SPO

    12 Pages

  105. SP

    13 Pages

  106. RPV pump

    8 Pages

  107. Pre-set

    6 Pages

  108. Flange

    13 Pages

  109. HML

    14 Pages

  110. VYR

    5 Pages

  111. VPLFC

    17 Pages

  112. SVB

    172 Pages

  113. SVR

    39 Pages

  114. 8mm Sensor

    22 Pages

  115. Vacuum Filter

    28 Pages

  116. Vacuum Pen

    21 Pages

  117. cylinder

    22 Pages

  118. FDAbellows

    6 Pages

  119. Oval

    80 Pages

  120. sponge

    50 Pages

  121. mark-free

    34 Pages

  122. flat

    42 Pages

  123. Ultrathin

    34 Pages

  124. packaging bag

    13 Pages

  125. multi-bellow

    46 Pages

  126. bellows pad

    74 Pages

  127. Skid proof pad

    42 Pages

  128. soft pad

    66 Pages

  129. VRL

    17 Pages

  130. VZ

    34 Pages

  131. VX

    42 Pages

  132. VVV

    11 Pages

  133. VQ

    42 Pages

  134. VN

    40 Pages

  135. VLS

    4 Pages

  136. VLM

    12 Pages

  137. VK

    53 Pages

  138. VJ

    34 Pages

  139. VG

    21 Pages

  140. Vacuum Tube

    12 Pages

  141. Twin Coiling

    12 Pages

  142. Tube Cutter

    12 Pages

  143. Insert Ring

    12 Pages

  144. UL series

    12 Pages

  145. K series

    30 Pages

  146. Color Cap

    12 Pages

  147. SSNC series

    13 Pages

  148. SJSC series

    24 Pages

  149. KJSC series

    17 Pages

  150. Check Valve

    4 Pages

  151. JSG

    17 Pages

  152. GENERAL

    106 Pages

  153. Change Valve

    11 Pages

  154. SVA21 Series

    21 Pages

  155. P Series

    71 Pages

  156. SVA20 Series

    43 Pages

  157. BJSU series

    6 Pages

  158. NP68-01e

    17 Pages