cad

Ball Valve Series
19Pages

{{requestButtons}}

Catalog excerpts

Ball Valve Series - 1

VALVE TUBE MAKE-TO-ORDER PRODUCTS Push-In Fitting Type Shut-off Valve Ball Valve Series ● Control Effective Area for Variety of Tube Dia. Adjustable lever with Scale for 10 series Shut-off Valve Material for 20/60 Series. Water can be used. Mechanical

Open the catalog to page 1
Ball Valve Series - 2

Valve Series ■ Model Designation (Example) BV Ball Valve Series Ball Valve ② Effective area (Series) Union Straight Unequal Dia. Union Straight Bulkhead Union Straight Union Elbow Unequal Dia. Union Elbow Bulkhead Union Elbow ② Effective area (Series)  No code: 10mm2  20: 20mm2  60: 60mm2 ③ Port 1 size mm Tube dia. (mm) Taper pipe thread size ※ Code in ( ) is for code for 10 Series Change Valve ④ Port 2 size mm Tube dia. (mm) Taper pipe thread size ※ Code in ( ) is for code for 10 Series ■ Air (Water) can be supplied from both sides.  10 Series : To open the valve, turn the lever 90 degrees...

Open the catalog to page 2
Ball Valve Series - 3

Fluid medium Operating pressure range Operating temp. range Machine screw (Steel) Ball presser (Nickel-plated brass) MAKE-TO-ORDER PRODUCTS ■ Construction (20/60 Series Union (Handle : Close)) Warning ※ Make sure to follow the instructions below when the fluid medium is water. 1. Surge pressure must be controlled lower than max. operating pressure when using water as a fluid medium. 2. Tap water can be used. Consult with PISCO for using other kind of water. 3. Be sure to place Insert Ring into the tube edge when using water as a fluid medium. Effective area Stem (Nickel-plated brass)...

Open the catalog to page 3
Ball Valve Series - 4

Valve Series Ball Valve Series ■ Standard Size List 10 Series: Thread ⇔ Tube Type BVC Straight BVLC Elbow Tube O.D.(mm) BVLC Elbow 10 Series: Tube ⇔ Tube Type BVU Union Straight P.569 BVG Unequal Dia. Union Straight P.569 BVM Bulkhead Union Straight P.570 Tube O.D.1 (mm) 4 BVLU Union Elbow P.570 6 4 BVLG Unequal Dia. Union Elbow P.570 6 6 BVLM Bulkhead Union Elbow P.571 Type 20/60 Series: Thread ⇔ Tube Type BVC Straight Type BVLC Elbow 20/60 Series: Tube ⇔ Tube Type BVG Unequal Dia. Union Straight P.572 Change Valve BVM Bulkhead Union Straight P.573

Open the catalog to page 4
Ball Valve Series - 5

■ How to insert and disconnect 1. How to insert and disconnect tubes ① Tube insertion  Insert a tube into Push-In Fitting up to the tube end. Lock-claws bite the tube and fix it automatically, then the elastic sleeve seals around the tube.  Refer to 2. Instructions for Tube Insertion under Common Safety Instructions  The tube is disconnected by pushing release-ring to release Lock-claws.  Make sure to stop air supply before the tube disconnection. MAKE-TO-ORDER PRODUCTS 2. How to tighten thread ① Tightening thread  Use a spanner to tighten a hexagonal-column of BVC and BVLC type.  Refer to...

Open the catalog to page 5
Ball Valve Series - 6

Valve Series ■ 10 Series BVU Union Straight Ball Valve Series Tube end Effective area (mm2) C2 BVG Unequal Dia. Union Straight Model code Change Valve Shut-off Valve Unit:mm Effective area (mm2) ※ L is a reference value for height dimension after tightening thread. 3D 3D CAD data is available at PISCO website. CAD

Open the catalog to page 6
Ball Valve Series - 7

BVM Bulkhead Union Straight BVLU Union Elbow 10 3D 3D CAD data is available at PISCO website. CAD Effective area Weight CAD (mm2) (g) file name CAD CAD data is available at PISCO website. Mechanical Valve Tube O.D. Tube O.D. Model code øD1 øD2 Shut-off Valve BVLG Unequal Dia. Union Elbow MAKE-TO-ORDER PRODUCTS ※ Release-ring on the bulkhead side is round shape. Tube O.D. Model code øD

Open the catalog to page 7
Ball Valve Series - 8

Valve Series ■ 10 Series BVLC Elbow 10 Ball Valve Series Unit:mm Model code BVLC4-01 BVLC6-01 ※ Reference value for height dimension after tightening thread. Unit:mm Effective area (mm2) ※ Reference value for height dimension after tightening thread. ※ Release-ring on the bulkhead side is round shape. 3D 3D CAD data is available at PISCO website. CAD Shut-off Valve BVLM Bulkhead Union Elbow Change Valve Model code

Open the catalog to page 8
Ball Valve Series - 9

■ 20/60 Series BVU Union Straight BVG Unequal Dia. Union Straight Tube O.D. Tube O.D. Model code øD1 øD2 BVG20-0806 BVG60-1210 Unit:mm Tube end Tube end C1 C2 Hex. Effective area Weight CAD (mm2) (g) file name H ※ L1 and L2 are reference values for height dimensions after tightening thread. 3D 3D CAD data is available at PISCO website. CAD CAD CAD data is available at PISCO website. Mechanical Valve Shut-off Valve Effective area Weight CAD (mm2) (g) file name Tube O.D. Model code øD

Open the catalog to page 9
Ball Valve Series - 10

Valve Series ■ 20/60 Series 36 BVLU Union Elbow Hex. Hex. Effective area Weight CAD H1 H2 (mm2) (g) file name Unit:mm CAD Effective area Weight (mm2) (g) file name Tube O.D. Tube O.D. Model code øD1 øD2 6 8 10 12 Shut-off Valve BVLG Unequal Dia. Union Elbow Change Valve Tube O.D. Model code øD BVM Bulkhead Union Straight Ball Valve Series Effective area Weight CAD (mm2) (g) file name 3D 3D CAD data is available at PISCO website. CAD

Open the catalog to page 10
Ball Valve Series - 11

BVLC Elbow Hex. Effective area Weight CAD H (mm2) (g) file name ※ L1 and L2 are reference values for height dimensions after tightening thread. BVLM Bulkhead Union Elbow Hex. Effective area Weight CAD (mm2) (g) file name H2 19 27 3D 3D CAD data is available at PISCO website. CAD CAD CAD data is available at PISCO website. Mechanical Valve Model code Shut-off Valve Unit:mm Tube O.D. Tube O.D. Model code øD1 øD2 MAKE-TO-ORDER PRODUCTS

Open the catalog to page 11
Ball Valve Series - 12

Valve Series Ball Valve Series 575 Change Valve Shut-off Valve

Open the catalog to page 12
Ball Valve Series - 13

Safety Instructions SAFETY Instructions  This safety instructions aim to prevent personal injury and damage to properties by requiring proper use of PISCO products.  Be certain to follow ISO 4414 and JIS B 8370 ISO 4414Pneumatic fluid power…Recomendations for the application of equipment to transmission and control systems. JIS B 8370General rules and safety requirements for systems and their components. This safety instructions is classified into “Danger”, “Warning” and “Caution” depending on the degree of danger or damages caused by improper use of PISCO products. Danger Hazardous...

Open the catalog to page 13
Ball Valve Series - 14

http://www.pisco.co.jp http://www.pisco.co.jp Disclaimer 1. PISCO does not take any responsibility for any incidental or indirect loss, such as production line stop, interruption of business, loss of benefits, personal injury, etc., caused by any failure on use or application of PISCO products. 2. PISCO does not take any responsibility for any loss caused by natural disasters, fires not related to PISCO products, acts by third parties, and intentional or accidental damages of PISCO products due to incorrect usage. 3. PISCO does not take any responsibility for any loss caused by improper...

Open the catalog to page 14

All NIHON PISCO CO. catalogs and technical brochures

  1. CTB series

    1 Pages

  2. FUS8 series

    3 Pages

  3. 31 & 32 Series

    20 Pages

  4. VP series

    106 Pages

  5. CHA series

    8 Pages

  6. Gripper Series

    15 Pages

  7. SVB Series

    50 Pages

  8. SVA series

    13 Pages

  9. SVR series

    31 Pages

  10. NSB series

    8 Pages

  11. BV series

    8 Pages

  12. HV series

    5 Pages

  13. HPO

    12 Pages

  14. HPU

    12 Pages

  15. PJN series

    15 Pages

  16. KJNC series

    15 Pages

  17. SSJS series

    6 Pages

  18. UE series

    12 Pages

  19. FB series

    1 Pages

  20. CTA series

    1 Pages

  21. SFTN series

    2 Pages

  22. SET series

    1 Pages

  23. SFT series

    14 Pages

  24. ULF series

    12 Pages

  25. UCQ series

    2 Pages

  26. UQ series

    12 Pages

  27. NB series

    12 Pages

  28. NA series

    12 Pages

  29. UD series

    12 Pages

  30. UBS series

    12 Pages

  31. UBT series

    12 Pages

  32. UC series

    1 Pages

  33. UB series

    12 Pages

  34. AK/AS series

    26 Pages

  35. NK series

    18 Pages

  36. Brass Series

    30 Pages

  37. V-0 series

    27 Pages

  38. EG Series

    27 Pages

  39. PP Series

    26 Pages

  40. AP series

    18 Pages

  41. SL series

    16 Pages

  42. P-SUS series

    33 Pages

  43. NS series

    24 Pages

  44. SSP series

    8 Pages

  45. ATS series

    6 Pages

  46. Air Filter

    20 Pages

  47. SFU series

    9 Pages

  48. JP series

    15 Pages

  49. ET series

    11 Pages

  50. EQ series

    19 Pages

  51. CVLU series

    21 Pages

  52. CV series

    24 Pages

  53. JN series

    25 Pages

  54. JSD series

    10 Pages

  55. JSC series

    13 Pages

  56. JS series

    30 Pages

  57. MA series

    16 Pages

  58. RH series

    16 Pages

  59. R series

    16 Pages

  60. PS series

    16 Pages

  61. L series

    41 Pages

  62. FUS20

    7 Pages

  63. GP series

    13 Pages

  64. VUS12 series

    2 Pages

  65. VUS21 series

    14 Pages

  66. VUS8-S series

    22 Pages

  67. JSD series

    10 Pages

  68. JK series

    10 Pages

  69. RVFUP series

    6 Pages

  70. VLF series

    16 Pages

  71. VFL series

    8 Pages

  72. VF series

    22 Pages

  73. ECV series

    8 Pages

  74. VPKE series

    4 Pages

  75. RPV06 Series

    8 Pages

  76. VZ Series

    34 Pages

  77. VX Series

    42 Pages

  78. VQ Series

    4 Pages

  79. VN Series

    40 Pages

  80. VK series

    53 Pages

  81. VJ Series

    34 Pages

  82. VG series

    21 Pages

  83. VRL series

    17 Pages

  84. VVV series

    11 Pages

  85. VLS series

    4 Pages

  86. VM | VC series

    28 Pages

  87. VY series

    24 Pages

  88. VB series

    11 Pages

  89. VH | VS series

    28 Pages

  90. VPHMP series

    12 Pages

  91. VYR series

    5 Pages

  92. HS series

    13 Pages

  93. HML series

    14 Pages

  94. VRG series

    18 Pages

  95. VLM series

    12 Pages

  96. VSPE series

    5 Pages

  97. VT series

    21 Pages

  98. PB series

    13 Pages

  99. JSG series

    17 Pages

  100. pararel

    3 Pages

  101. fitting

    4 Pages

  102. BJSU series

    4 Pages

  103. SC

    15 Pages

  104. SPO

    12 Pages

  105. SP

    13 Pages

  106. RPV pump

    8 Pages

  107. Pre-set

    6 Pages

  108. Flange

    13 Pages

  109. HML

    14 Pages

  110. VYR

    5 Pages

  111. VPLFC

    17 Pages

  112. SVB

    172 Pages

  113. SVR

    39 Pages

  114. 8mm Sensor

    22 Pages

  115. Vacuum Filter

    28 Pages

  116. Vacuum Pen

    21 Pages

  117. cylinder

    22 Pages

  118. FDAbellows

    6 Pages

  119. Oval

    80 Pages

  120. sponge

    50 Pages

  121. mark-free

    34 Pages

  122. flat

    42 Pages

  123. Ultrathin

    34 Pages

  124. packaging bag

    13 Pages

  125. multi-bellow

    46 Pages

  126. bellows pad

    74 Pages

  127. Skid proof pad

    42 Pages

  128. soft pad

    66 Pages

  129. VRL

    17 Pages

  130. VZ

    34 Pages

  131. VX

    42 Pages

  132. VVV

    11 Pages

  133. VQ

    42 Pages

  134. VN

    40 Pages

  135. VLS

    4 Pages

  136. VLM

    12 Pages

  137. VK

    53 Pages

  138. VJ

    34 Pages

  139. VG

    21 Pages

  140. Vacuum Tube

    12 Pages

  141. Twin Coiling

    12 Pages

  142. Tube Cutter

    12 Pages

  143. Insert Ring

    12 Pages

  144. UL series

    12 Pages

  145. K series

    30 Pages

  146. Color Cap

    12 Pages

  147. SSNC series

    13 Pages

  148. SJSC series

    24 Pages

  149. KJSC series

    17 Pages

  150. Check Valve

    4 Pages

  151. JSG

    17 Pages

  152. GENERAL

    106 Pages

  153. Change Valve

    11 Pages

  154. SVA21 Series

    21 Pages

  155. P Series

    71 Pages

  156. SVA20 Series

    43 Pages

  157. BJSU series

    6 Pages

  158. NP68-01e

    17 Pages