Centrifugal Fans double inlet with direct drive forward curved blades
108Pages

{{requestButtons}}

Catalog excerpts

Centrifugal Fans double inlet with direct drive forward curved blades - 1

Centrifugal Fans double inlet with direct drive forward curved blades

Open the catalog to page 1
Centrifugal Fans double inlet with direct drive forward curved blades - 2

The overall picture will decide Complete systems by Nicotra Gebhardt Depending on the model of the fan, the efficiency grade “N” set in accordance with the ErP Directive must be achieved from 2013 and 2015 respectively. Efficiency grade “N” to ErP-Directive Centrifugal fans with backward curved blades without with housing housing static static total Centrifugal fans with forward curved blades with housing static total Nicotra Gebhardt can supply complete systems in all product categories which meet the ErP requirements. We offer highly efficient fan systems A ith matching components and...

Open the catalog to page 2
Centrifugal Fans double inlet with direct drive forward curved blades - 3

Flow rate Media temperature Speed control Casing material Inlet type Double inlet ErP status Single inlet Coated steel Galvanised steel Backward curved blades coated steel Forward curved blades galvanised sheet steel External Inverter

Open the catalog to page 3
Centrifugal Fans double inlet with direct drive forward curved blades - 4

proSELECTA II Simple and reliable selection proSELECTA II is a technical selection program that allows you to configure your own individually designed fan. It provides you with the opportunity to choose from the entire range of fan types and their associated options. The result from proSELECTA II is the provision of all the technical data for your fan, including sound level data, dimension specifications and accessories. Apart from that, as a registered user, your purchase prices are provided. Additionally fully dimensioned drawings in dxf format are available, which can be downloaded and...

Open the catalog to page 4
Centrifugal Fans double inlet with direct drive forward curved blades - 5

High performance centrifugal fans DDM double width, double inlet, (DWDI), with built-in, optimised external rotor motor, made of galvanised sheet steel; available in various models; Impeller with forward curved blades of galvanised steel plate High performance centrifugal fans DDMB double width, double inlet, (DWDI), with built-in, brushless DC external rotor motor and external commutation unit, made of galvanised sheet steel; available in various models; Impeller with forward curved blades of galvanised steel plate High performance centrifugal fans DD double width, double inlet, (DWDI),...

Open the catalog to page 5
Centrifugal Fans double inlet with direct drive forward curved blades - 6

The best fan for your application! DDM range – direct driven fans Direct driven centrifugal fans of DDM range with forward curved impeller directly mounted on the external rotor motor are the ideal solution for your applications in the HVAC business. The fact of manufacturing by ourselves each fan component – the casing, the impeller and motor – enables us to create fans that perfectly meet the requirements of high performances and low power consumptions. The wide range of different versions and motor types allows you to find the fan exactly matching what you really need. You anyway get the...

Open the catalog to page 6
Centrifugal Fans double inlet with direct drive forward curved blades - 7

This kind of fans are specially conceived for use in dust-free environments, at temperatures up to +40 °C, or higher on selected models. The performance data have been obtained in a laboratory registered by AMCA for AMCA 210/99 air performance testing. Data are not certified by AMCA. We have the right fan for all your application! Many different sizes, versions and motor types are available in the DDM range. Impeller size (width and diameter) up to 15“ Speed variation either by step-transformers or stepless External rotor motor with integrated thermal protector Fan models suitable for 60 Hz...

Open the catalog to page 7
Centrifugal Fans double inlet with direct drive forward curved blades - 8

Direct driven centrifugal fans / DDM / Technical Data Technical Data Speed control Nominal motor power Poles W – Nominal capacitor voltage V Motor protection class Motor thermal class Thermal protection Density of media kg/m³ Mains Connection frequency Hz Max. current consumption Speed A 1/min 0.5 Article number Technical Data Attention! We suggest to do not use the fan in the grey marked area! The noise ratings given in the performance curves are sound power level LWA7, see „Technical Description“. (1) = Speed controllable via Transformer (2) = Speed controllable via TRIAC or Transformer...

Open the catalog to page 8
Centrifugal Fans double inlet with direct drive forward curved blades - 9

Direct driven centrifugal fans / DDM / Technical Data Technical Data Speed control Nominal motor power Poles W – Nominal capacitor voltage V Motor protection class Motor thermal class Thermal protection Density of media kg/m³ Mains Connection frequency Hz Max. current consumption Speed A 1/min Article number Technical Data Attention! We suggest to do not use the fan in the grey marked area! The noise ratings given in the performance curves are sound power level LWA7, see „Technical Description“. (1) = Speed controllable via Transformer (2) = Speed controllable via TRIAC or Transformer (3) =...

Open the catalog to page 9
Centrifugal Fans double inlet with direct drive forward curved blades - 10

Direct driven centrifugal fans / DDM / Technical Data Technical Data Speed control Nominal motor power Poles W – Nominal capacitor voltage V Motor protection class Motor thermal class Thermal protection Density of media kg/m³ Mains Connection frequency Hz Max. current consumption Speed A 1/min 0.9 Article number Technical Data Attention! We suggest to do not use the fan in the grey marked area! The noise ratings given in the performance curves are sound power level LWA7, see „Technical Description“. (1) = Speed controllable via Transformer (2) = Speed controllable via TRIAC or Transformer...

Open the catalog to page 10
Centrifugal Fans double inlet with direct drive forward curved blades - 11

Direct driven centrifugal fans / DDM / Technical Data Technical Data Speed control Nominal motor power Poles W – Nominal capacitor voltage V Motor protection class Motor thermal class Thermal protection Density of media kg/m³ Mains Connection frequency Hz 50/60 Max. current consumption Speed A 1/min Article number Technical Data Attention! We suggest to do not use the fan in the grey marked area! The noise ratings given in the performance curves are sound power level LWA7, see „Technical Description“. (1) = Speed controllable via Transformer (2) = Speed controllable via TRIAC or Transformer...

Open the catalog to page 11
Centrifugal Fans double inlet with direct drive forward curved blades - 12

Direct driven centrifugal fans / DDM / Technical Data Technical Data Speed control Nominal motor power Poles W – Nominal capacitor voltage V Motor protection class Motor thermal class Thermal protection Density of media kg/m³ Mains Connection frequency Hz Max. current consumption Speed A 1/min Article number Technical Data Attention! We suggest to do not use the fan in the grey marked area! The noise ratings given in the performance curves are sound power level LWA7, see „Technical Description“. (1) = Speed controllable via Transformer (2) = Speed controllable via TRIAC or Transformer (3) =...

Open the catalog to page 12

All Nicotra Gebhardt catalogs and technical brochures

  1. RDP

    56 Pages

  2. DDMP

    72 Pages

  3. RLMEVO