Centrifugal Fans direct driven with scroll
77Pages

{{requestButtons}}

Catalog excerpts

Centrifugal Fans direct driven with scroll - 2

The overall picture will decide Complete systems by Nicotra Gebhardt Depending on the model of the fan, the efficiency grade “N” set in accordance with the ErP Directive must be achieved from 2013 and 2015 respectively. Efficiency grade “N” to ErP-Directive Centrifugal fans with backward curved blades without with housing housing static static total Centrifugal fans with forward curved blades with housing static total Nicotra Gebhardt can supply complete systems in all product categories which meet the ErP requirements. We offer highly efficient fan systems A ith matching components and...

Open the catalog to page 2
Centrifugal Fans direct driven with scroll - 3

Flow rate Media temperature Speed control Casing material Inlet type Coated steel Single inlet Double inlet Galvanised steel Forward curved blades galvanised sheet steel Backward curved blades coated steel External Inverter

Open the catalog to page 3
Centrifugal Fans direct driven with scroll - 4

Nicotra Gebhardt technologies like ... Automated manufacture of compact scroll and impeller with forward curved blades Own AC and Brushless-DC motor production for optimal tuniung of motor and fan! proSELECTA II Simple and reliable selection proSELECTA II is a technical selection program that allows you to configure your own individually designed fan. It provides you with the opportunity to choose from the entire range of fan types and their associated options. The result from proSELECTA II is the provision of all the technical data for your fan, including sound level data, dimension...

Open the catalog to page 4
Centrifugal Fans direct driven with scroll - 5

High performance centrifugal fans DDM double width, double inlet, (DWDI), with built-in, optimised external rotor motor, made of galvanised sheet steel; available in various models; Impeller with forward curved blades of galvanised steel plate High performance centrifugal fans DDMB double width, double inlet, (DWDI), with built-in, brushless DC external rotor motor and external commutation unit, made of galvanised sheet steel; available in various models; Impeller with forward curved blades of galvanised steel plate High performance centrifugal fans DD double width, double inlet, (DWDI),...

Open the catalog to page 5
Centrifugal Fans direct driven with scroll - 6

The best fan for your application! DD range – direct driven fans Direct driven centrifugal fans of DD range with forward curved impeller directly mounted on the shaft of the internal rotor motor are the ideal solution for your applications in the HVAC business. The fact of manufacturing by ourselves each fan component – the casing, the impeller and motor – enables us to create fans that perfectly meet the requirements of high performances and low power consumptions. The wide range of different versions and motor types allows you to find the fan exactly matching what you really need. You...

Open the catalog to page 6
Centrifugal Fans direct driven with scroll - 7

Program overview: DD range This kind of fans are specially conceived for use in dust-free environments, at temperatures up to +40°C, or higher on selected models. The performance data have been obtained in a laboratory registered by AMCA for AMCA 210/99 air performance testing. Data are not certified by AMCA. Fan range DD • Impeller size (width and diameter) up to 18“ • Speed variation either by step-transformers or stepless • Internal rotor motor with intergrated thermal protector • Fan models suitable for 60Hz supply are available • Air Flow up to 18,000m³/h • Static pressure up to 800Pa...

Open the catalog to page 7
Centrifugal Fans direct driven with scroll - 8

Direct driven centrifugal fans / DD / Technical Data

Open the catalog to page 8
Centrifugal Fans direct driven with scroll - 9

Direct driven centrifugal fans / DD / Technical Data Nominal capacitor voltage V 450 Technical Data Nominal motor power Poles W – 40 4 Motor protection class Motor ther- Thermal mal class protection (1) = Speed controllable via Transformer (2) = Speed controllable via TRIAC or Transformer (3) = Speed controllable via Inverter * = No speed control available Media Temperature max. Fan weight °C kg 70 6 Density of media kg/m³ 1.2 Article number Max. power Max. current consumption consumption Speed W A 1/min 123 0.5 1280 [HI] High speed, [ME] Medium speed, [LO] Low speed Attention! We suggest...

Open the catalog to page 9
Centrifugal Fans direct driven with scroll - 10

Direct driven centrifugal fans / DD / Technical Data

Open the catalog to page 10
Centrifugal Fans direct driven with scroll - 11

Direct driven centrifugal fans / DD / Technical Data Nominal capacitor voltage V 450 450 450 Technical Data (1) = Speed controllable via Transformer (2) = Speed controllable via TRIAC or Transformer (3) = Speed controllable via Inverter * = No speed control available Nominal motor power W 92 105 45 Motor protection class Motor ther- Thermal mal class protection Article number Density of Fan weight media kg kg/m³ 5 1.2 5 1.2 6 1.2 [HI] High speed, [ME] Medium speed, [LO] Low speed Attention! We suggest to do not use the fan in the grey marked area! The noise ratings given in the performance...

Open the catalog to page 11
Centrifugal Fans direct driven with scroll - 12

Direct driven centrifugal fans / DD / Technical Data

Open the catalog to page 12
Centrifugal Fans direct driven with scroll - 13

Direct driven centrifugal fans / DD / Technical Data Nominal capacitor voltage V 450 450 Technical Data Nominal motor power W 1000 900 750 Motor protection class Motor ther- Thermal mal class protection (1) = Speed controllable via Transformer (2) = Speed controllable via TRIAC or Transformer (3) = Speed controllable via Inverter * = No speed control available Mains Connection frequency Hz 50 50 D/Y 50/60 Media Temperature max. °C 40 40 40 Density of Fan weight media kg kg/m³ 10 1.2 10 1.2 8 1.2 Article number [HI] High speed, [ME] Medium speed, [LO] Low speed Attention! We suggest to do...

Open the catalog to page 13
Centrifugal Fans direct driven with scroll - 14

Direct driven centrifugal fans / DD / Technical Data

Open the catalog to page 14
Centrifugal Fans direct driven with scroll - 15

Direct driven centrifugal fans / DD / Technical Data Nominal capacitor voltage V 450 450 450 Technical Data (1) = Speed controllable via Transformer (2) = Speed controllable via TRIAC or Transformer (3) = Speed controllable via Inverter * = No speed control available Motor protection class Motor ther- Thermal mal class protection Mains Connection frequency Hz 50/60 50/60 50/60 Media Temperature max. °C 40 40 50 Density of Fan weight media kg kg/m³ 9 1.2 6 1.2 7 1.2 Article number [HI] High speed, [ME] Medium speed, [LO] Low speed Attention! We suggest to do not use the fan in the grey...

Open the catalog to page 15
Centrifugal Fans direct driven with scroll - 16

Direct driven centrifugal fans / DD / Technical Data

Open the catalog to page 16

All Nicotra Gebhardt catalogs and technical brochures

  1. RDP

    56 Pages

  2. DDMP

    72 Pages

  3. RLMEVO

    36 Pages