1. Catalogs
  2. NGI Tech
  3. N6200 series User Manual medium power programmable dc electronic load

N6200 series User Manual medium power programmable dc electronic load

N6200 series User Manual medium power programmable dc electronic load
1 / 71 PagesView full catalog

N6200 series User Manual medium power programmable dc electronic load

Product catalog summary
Preface
The manual introduces the N6200 series DC electronic load by Hunan Next Generation Instrumental T&C Tech. Co., Ltd. (NGI), emphasizing NGI's dedication to high-quality test and control instruments. It covers installation, operation, and specifications, stressing adherence to safety instructions.
Safety Instructions
Users must follow safety guidelines, including confirming AC input voltage, ensuring reliable grounding, and avoiding hazardous conditions. Safety symbols used throughout the manual are explained.
Product Overview
The N6200 series is designed for high accuracy and reliability, suitable for benchtop or rack installation. Features include high power density, stable CR/CP functions, editable slew rates, Ethernet and serial communication support, powerful charging and discharging control modes, a built-in ESR test function, and dynamic mode capabilities up to 20kHz.
Functions and Features
The manual details operational modes such as Constant Current, Voltage, Resistance, and Power modes, along with dynamic modes like Continuous, Pulse, and Toggle. Additional features include auto test functions, discharge and charge tests, and overcurrent protection tests. The series supports remote and local sensing, programmable protection, and has a power-off memory function.
Local Operation
This section explains the use of buttons, the LCD screen, and menu navigation for local operation, covering system, application, and protection settings, as well as factory reset procedures.
Operation Guideline
Guidelines for static and dynamic operations are provided, including parameter settings and mode selections. The section also covers auto test procedures, capacity tests, and optional ESR and OCP tests.
Maintenance and Self-Inspection
Regular maintenance and fault self-inspection procedures are outlined to ensure the instrument's longevity and proper functioning.
Main Technical Data
The manual concludes with technical specifications for the N6200 series models, providing detailed information for optimal use.
Specifications Overview
The document outlines various models of the N6200 series DC electronic loads, detailing their power, voltage, and current specifications, with power ratings ranging from 600W to 1800W.
Package Contents and Accessories
Users should inspect for transportation damage and verify the inclusion of accessories such as a power cord, RS232 cable, Ethernet cable, and USB flash drive containing manuals and software.
Panel Introduction
The front panel includes a power switch, screen, function buttons, numeric buttons, and a knob. The rear panel features input terminals, control signal terminals, a LAN port, and an AC power socket.
Installation Instructions
Ensure a 20cm gap for air circulation due to built-in fans. The power cord must match local voltage and plug type. A power-on self-test is conducted upon startup.
Connection Guidelines
Input connections should consider wire diameter, length, and polarity. Control connections include terminals for remote sensing and external programming. Remote sense is recommended for accurate measurements.
Testing Functions
Auto test functions simulate waveforms to improve efficiency, supporting up to 100 sequence files. Discharge and charge tests are available for batteries and supercapacitors. ESR measurement and over-current protection tests are supported.
Programmable Protection
N6200 offers programmable protection, including current limit, over voltage protection (OVP), over current protection (OCP), and over power protection (OPP), each shutting down the input and displaying an alarm when thresholds are exceeded.
Protection Functions
N6200 provides multiple protection functions, including OCP, OVP, OPP, Reverse Polarity Warning, Over Temperature Protection, Power Module Over Temperature, Temperature Sensor Failure, and Power Module Missing.
Slew Rate and Transition Time
Slew rate defines the change of voltage or current per unit time, minimizing transition time between values.
Save and Recall
N6200 can save up to 20 parameter groups in EEPROM for easy recall, with Fast Recall allowing quick access to the first 10 groups.
Power-off Memory
This function saves data during power-off or failure, ensuring data retention.
Language Options
N6200 supports Chinese and English languages, selectable via the menu.
Control and Monitor
Remote sense terminals ensure accurate voltage measurement. Current monitoring outputs a voltage proportional to input current. External programming input allows control of CC mode via a 0-10V signal.
Factory Reset
Factory reset restores default settings but retains EEPROM data. External programming is limited to CC and CV modes.
Operation Guidelines
N6200 supports static operation modes including constant current, voltage, resistance, and power. Range selection ensures measurement accuracy.
Current and Slew Setting
Two methods are provided to set parameters like I-Set, Rise Slew, and Fall Slew under Constant Current mode.
Constant Voltage Mode
To enter CV mode, users can press the CV button or navigate through the menu, with two voltage range options ensuring measurement accuracy.
Constant Resistance Mode
CR mode can be accessed via the CR button or menu, with range selection available.
Constant Power Mode
CP mode is accessible via the CP button or menu navigation, with power and slew settings adjusted similarly to other modes.
Dynamic Operation
The dynamic function tests the dynamic characteristics of the DUT with modes like CCD, CVD, and CRD, including continuous, pulse, and toggle options.
Auto Test
The auto test feature allows users to edit sequences to simulate various load input changes.
Capacity Test
The N6200 series supports capacity tests for batteries and capacitors, involving setting parameters like I-Discharge and V-End.
ESR Test (Optional)
The ESR test evaluates battery and capacitor ESR using a constant current discharge method.
Operational Procedures
Includes setting discharge current, ESR test steps, OCP test procedures, and MPPT test steps.
Maintenance and Self-inspection
Regular maintenance includes cleaning and fault self-inspection, with annual calibration recommended.
Main Technical Data
Includes measurement accuracy conditions, model specifications, and operating environment details.
Key Specifications
Details voltage and current ranges, power and resistance modes, and interface and input requirements.
See more

Catalog excerpts

N6200 series User Manual medium power programmable dc electronic load-1

Hunan Next Generation Instrumental T&C Tech. Co., Ltd. N6200 Series Wide Range Medium Power DC Electronic Load User Manual © Copyright Hunan Next Generation Instrumental T&C Tech. Co., Ltd. Version: V20210814 N6200 Series Wide Range Medium Power DC Electronic Load

 Open the catalog to page 1
N6200 series User Manual medium power programmable dc electronic load-2

Hunan Next Generation Instrumental T&C Tech. Co., Ltd. N6200 Series Wide Range Medium Power DC Electronic Load

 Open the catalog to page 2
N6200 series User Manual medium power programmable dc electronic load-3

Hunan Next Generation Instrumental T&C Tech. Co., Ltd. N6200 Series Wide Range Medium Power DC Electronic Load

 Open the catalog to page 3
N6200 series User Manual medium power programmable dc electronic load-4

Hunan Next Generation Instrumental T&C Tech. Co., Ltd. N6200 Series Wide Range Medium Power DC Electronic Load

 Open the catalog to page 4
N6200 series User Manual medium power programmable dc electronic load-5

Hunan Next Generation Instrumental T&C Tech. Co., Ltd. 1 Preface Dear Customers, First of all, we greatly appreciate your choice of N6200 series DC electronic load (N6200 for short). We are also honored to introduce our company, Hunan Next Generation Instrumental T&C Tech. Co., Ltd. ( NGI for short). About Company NGI is a professional manufacturer of intelligent equipment and test & control instruments, committed to developing, manufacturing battery simulators, power supplies, electronic loads, and many more instruments. The products can be widely used in the industries of battery, power supply,...

 Open the catalog to page 5
N6200 series User Manual medium power programmable dc electronic load-6

Hunan Next Generation Instrumental T&C Tech. Co., Ltd. 2 Safety Instructions In the operation and maintenance of the instrument, please strictly comply with the following safety instructions. Any performance regardless of attentions or specific warnings in other chapters of the manual may impair the protective functions provided by the instrument. NGI shall not be liable for the results caused by the neglect of those instructions. 2.1 Safety Notes > Confirm the AC input voltage before supplying power. > Reliable grounding: Before operation, the instrument must be reliably grounded to avoid the...

 Open the catalog to page 6
N6200 series User Manual medium power programmable dc electronic load-7

Hunan Next Generation Instrumental T&C Tech. Co., Ltd. 3 Product 3.1.1 Brief Introduction N6200 series is developed based on NGI's years of experience in testing for power supply and battery. It is with high accuracy, high reliability and high cost performance. N6200 series is with high power density and elegant appearance, which is available for benchtop use or installation in 19 inch rack. 3.1.2 Features ■ High power density, minimizing space occupation ■ Stable and reliable CR/CP function supported by hardware ■ Editable rise and fall slew rate ■ Supporting Ethernet, serial communication and...

 Open the catalog to page 7
N6200 series User Manual medium power programmable dc electronic load-8

Hunan Next Generation Instrumental T&C Tech. Co., Ltd. 3.2 Overview 3.2.1 N6200 Series Lineup If any loss or damage, please contact NGI. 4. Check the whole instrument. If N6200 chassis is damaged or has abnormal operation, please contact our authorized distributor or NGI. NGI l NGI N6200 Series Wide Range Medium Power DC Electronic Load

 Open the catalog to page 8
N6200 series User Manual medium power programmable dc electronic load-9

Hunan Next Generation Instrumental T&C Tech. Co., Ltd. Programmable DC Electronic Load Front Panel Dimension(mm) Rear Panel Dimension(mm) Side Dimension(mm) N6200 Series Wide Range Medium Power DC Electronic Load

 Open the catalog to page 9
N6200 series User Manual medium power programmable dc electronic load-10

Hunan Next Generation Instrumental T&C Tech. Co., Ltd. 3.3 Panel Introduction 3.3.1 Front Panel Introduction Table 4 3.3.2 Rear Panel Introduction Number NGI l NGI N6200 Series Wide Range Medium Power DC Electronic Load

 Open the catalog to page 10
N6200 series User Manual medium power programmable dc electronic load-11

Hunan Next Generation Instrumental T&C Tech. Co., Ltd. 3.4 Installation Instruction N6200 dissipates heat through the built-in fans. When installing, please make sure there is a gap of at least 20cm between N6200 and other objects for air circulation. The power cord is a 3-core wire with grounding protection. Please use a suitable socket for operation. The power cord also matches your local voltage and plug type. If it is not matched, please contact NGI. 3.4.2 Power-on Self Test Before power-on, please make sure the following. 1) The nominal voltage of the AC input socket should be in the correct...

 Open the catalog to page 11
N6200 series User Manual medium power programmable dc electronic load-12

Hunan Next Generation Instrumental T&C Tech. Co., Ltd. In case of test failure, please record the error information and contact NGI for support. If N6200 cannot be started properly, please refer to the following steps. 1) Check whether the power cord is properly connected. 2) Check whether the power is switched on. 3) Check whether the fuse is burned out.  If yes, please replace it.  Please use the proper fuse.  When replacing, please open the plastic cover at the AC power socket. For more support, please contact NGI. 3.5 Connection 3.5.1 Input Connection Warning: To meet safety requirements,...

 Open the catalog to page 12
N6200 series User Manual medium power programmable dc electronic load-13

Hunan Next Generation Instrumental T&C Tech. Co., Ltd. Meanwhile exceeding heating may cause safety accidents. It is recommended to use standard copper wire with bigger diameter and less length to ensure the voltage drop should be less than 0.5V while N6200 is working. Notice: To meet higher slew rate load specification and performance, the inductance of the wire between DUT and N6200 should be less than 5.0^H. 3.5.2 Control Connection At the rear panel, there are terminals for remote sense, external programming input, etc. Figure 7 Control Signal Terminal Table 6 Terminal Definition NGI l NGI...

 Open the catalog to page 13
N6200 series User Manual medium power programmable dc electronic load-14

Hunan Next Generation Instrumental T&C Tech. Co., Ltd. Note: The input voltage range for external programming is 0 ~ 10V. Input voltage below 0V or above 10V may cause abnormal operation or even damage to N6200. 3.5.3 Sense Connection N6200 provides two types of sense: local sense and remote sense. User can select sense mode on the screen under Application on the menu.  Local sense It is used when the load current is not very high.  Remote sense Remote sense is also four-wire sense. When N6200 is working, it will cause a voltage drop in the leads between the DUT and terminals of N6200, which...

 Open the catalog to page 14
N6200 series User Manual medium power programmable dc electronic load-15

Hunan Next Generation Instrumental T&C Tech. Co., Ltd. Low Voltage Test Connection N6200 Series Wide Range Medium Power DC Electronic Load

 Open the catalog to page 15
N6200 series User Manual medium power programmable dc electronic load-16

Hunan Next Generation Instrumental T&C Tech. Co., Ltd. 4 Functions and Features This chapter mainly describes the functions and features of N6200 series. N6200 provides two control modes: local control and remote control. Under local control mode, users can set and operate through N6200 buttons on front panel, and check N6200 status, parameters and readback data via the LCD screen. By remote control mode, it can realize most functions of local control. 4.1 Constant Current Mode (CC Mode) Under CC mode, N6200 consumes constant current no matter how the input voltage changes. Current range There...

 Open the catalog to page 16

All NGI Tech catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.