N6200 series User Manual medium power programmable dc electronic load
71Pages

{{requestButtons}}

Catalog excerpts

N6200 series User Manual medium power programmable dc electronic load - 1

Hunan Next Generation Instrumental T&C Tech. Co., Ltd. N6200 Series Wide Range Medium Power DC Electronic Load User Manual © Copyright Hunan Next Generation Instrumental T&C Tech. Co., Ltd. Version: V20210814 N6200 Series Wide Range Medium Power DC Electronic Load

Open the catalog to page 1
N6200 series User Manual medium power programmable dc electronic load - 2

Hunan Next Generation Instrumental T&C Tech. Co., Ltd. N6200 Series Wide Range Medium Power DC Electronic Load

Open the catalog to page 2
N6200 series User Manual medium power programmable dc electronic load - 3

Hunan Next Generation Instrumental T&C Tech. Co., Ltd. N6200 Series Wide Range Medium Power DC Electronic Load

Open the catalog to page 3
N6200 series User Manual medium power programmable dc electronic load - 4

Hunan Next Generation Instrumental T&C Tech. Co., Ltd. N6200 Series Wide Range Medium Power DC Electronic Load

Open the catalog to page 4
N6200 series User Manual medium power programmable dc electronic load - 5

Hunan Next Generation Instrumental T&C Tech. Co., Ltd. 1 Preface Dear Customers, First of all, we greatly appreciate your choice of N6200 series DC electronic load (N6200 for short). We are also honored to introduce our company, Hunan Next Generation Instrumental T&C Tech. Co., Ltd. ( NGI for short). About Company NGI is a professional manufacturer of intelligent equipment and test & control instruments, committed to developing, manufacturing battery simulators, power supplies, electronic loads, and many more instruments. The products can be widely used in the industries of battery, power...

Open the catalog to page 5
N6200 series User Manual medium power programmable dc electronic load - 6

Hunan Next Generation Instrumental T&C Tech. Co., Ltd. 2 Safety Instructions In the operation and maintenance of the instrument, please strictly comply with the following safety instructions. Any performance regardless of attentions or specific warnings in other chapters of the manual may impair the protective functions provided by the instrument. NGI shall not be liable for the results caused by the neglect of those instructions. 2.1 Safety Notes > Confirm the AC input voltage before supplying power. > Reliable grounding: Before operation, the instrument must be reliably grounded to avoid...

Open the catalog to page 6
N6200 series User Manual medium power programmable dc electronic load - 7

Hunan Next Generation Instrumental T&C Tech. Co., Ltd. 3 Product 3.1.1 Brief Introduction N6200 series is developed based on NGI's years of experience in testing for power supply and battery. It is with high accuracy, high reliability and high cost performance. N6200 series is with high power density and elegant appearance, which is available for benchtop use or installation in 19 inch rack. 3.1.2 Features ■ High power density, minimizing space occupation ■ Stable and reliable CR/CP function supported by hardware ■ Editable rise and fall slew rate ■ Supporting Ethernet, serial communication...

Open the catalog to page 7
N6200 series User Manual medium power programmable dc electronic load - 8

Hunan Next Generation Instrumental T&C Tech. Co., Ltd. 3.2 Overview 3.2.1 N6200 Series Lineup If any loss or damage, please contact NGI. 4. Check the whole instrument. If N6200 chassis is damaged or has abnormal operation, please contact our authorized distributor or NGI. NGI l NGI N6200 Series Wide Range Medium Power DC Electronic Load

Open the catalog to page 8
N6200 series User Manual medium power programmable dc electronic load - 9

Hunan Next Generation Instrumental T&C Tech. Co., Ltd. Programmable DC Electronic Load Front Panel Dimension(mm) Rear Panel Dimension(mm) Side Dimension(mm) N6200 Series Wide Range Medium Power DC Electronic Load

Open the catalog to page 9
N6200 series User Manual medium power programmable dc electronic load - 10

Hunan Next Generation Instrumental T&C Tech. Co., Ltd. 3.3 Panel Introduction 3.3.1 Front Panel Introduction Table 4 3.3.2 Rear Panel Introduction Number NGI l NGI N6200 Series Wide Range Medium Power DC Electronic Load

Open the catalog to page 10
N6200 series User Manual medium power programmable dc electronic load - 11

Hunan Next Generation Instrumental T&C Tech. Co., Ltd. 3.4 Installation Instruction N6200 dissipates heat through the built-in fans. When installing, please make sure there is a gap of at least 20cm between N6200 and other objects for air circulation. The power cord is a 3-core wire with grounding protection. Please use a suitable socket for operation. The power cord also matches your local voltage and plug type. If it is not matched, please contact NGI. 3.4.2 Power-on Self Test Before power-on, please make sure the following. 1) The nominal voltage of the AC input socket should be in the...

Open the catalog to page 11
N6200 series User Manual medium power programmable dc electronic load - 12

Hunan Next Generation Instrumental T&C Tech. Co., Ltd. In case of test failure, please record the error information and contact NGI for support. If N6200 cannot be started properly, please refer to the following steps. 1) Check whether the power cord is properly connected. 2) Check whether the power is switched on. 3) Check whether the fuse is burned out.  If yes, please replace it.  Please use the proper fuse.  When replacing, please open the plastic cover at the AC power socket. For more support, please contact NGI. 3.5 Connection 3.5.1 Input Connection Warning: To meet safety...

Open the catalog to page 12
N6200 series User Manual medium power programmable dc electronic load - 13

Hunan Next Generation Instrumental T&C Tech. Co., Ltd. Meanwhile exceeding heating may cause safety accidents. It is recommended to use standard copper wire with bigger diameter and less length to ensure the voltage drop should be less than 0.5V while N6200 is working. Notice: To meet higher slew rate load specification and performance, the inductance of the wire between DUT and N6200 should be less than 5.0^H. 3.5.2 Control Connection At the rear panel, there are terminals for remote sense, external programming input, etc. Figure 7 Control Signal Terminal Table 6 Terminal Definition NGI l...

Open the catalog to page 13
N6200 series User Manual medium power programmable dc electronic load - 14

Hunan Next Generation Instrumental T&C Tech. Co., Ltd. Note: The input voltage range for external programming is 0 ~ 10V. Input voltage below 0V or above 10V may cause abnormal operation or even damage to N6200. 3.5.3 Sense Connection N6200 provides two types of sense: local sense and remote sense. User can select sense mode on the screen under Application on the menu.  Local sense It is used when the load current is not very high.  Remote sense Remote sense is also four-wire sense. When N6200 is working, it will cause a voltage drop in the leads between the DUT and terminals of N6200,...

Open the catalog to page 14
N6200 series User Manual medium power programmable dc electronic load - 15

Hunan Next Generation Instrumental T&C Tech. Co., Ltd. Low Voltage Test Connection N6200 Series Wide Range Medium Power DC Electronic Load

Open the catalog to page 15
N6200 series User Manual medium power programmable dc electronic load - 16

Hunan Next Generation Instrumental T&C Tech. Co., Ltd. 4 Functions and Features This chapter mainly describes the functions and features of N6200 series. N6200 provides two control modes: local control and remote control. Under local control mode, users can set and operate through N6200 buttons on front panel, and check N6200 status, parameters and readback data via the LCD screen. By remote control mode, it can realize most functions of local control. 4.1 Constant Current Mode (CC Mode) Under CC mode, N6200 consumes constant current no matter how the input voltage changes. Current range...

Open the catalog to page 16

All NGI Tech catalogs and technical brochures