Preface
This manual is for the N39200 series high-accuracy dual-channel programmable DC power supply by Hunan Next Generation Instrumental T&C Tech. Co., Ltd. It includes installation, operation, and specifications, emphasizing the importance of reading safety instructions for proper use.
Safety Instructions
Users must confirm the AC input voltage, ensure reliable grounding, and verify correct fuse installation. The manual advises against operating under hazardous conditions and stresses operating within the device's rated range. Safety symbols for DC, AC, grounding, and warnings are explained.
Product Overview
The N39200 series is a high-accuracy, dual-channel programmable DC power supply suitable for benchtop use. It features automatic switching between constant voltage (CV) and constant current (CC) modes, a high-definition touch screen, remote sensing, and multiple protection mechanisms. Models vary in voltage, current, and power specifications.
Panel Introduction
The front panel includes a 4.3-inch touch screen, USB port, power switch, and buttons for menu navigation and parameter setting. The rear panel features channel interfaces, a LAN port, RS232 interface, and grounding options.
Power-On Test
Instructions for preparing the device for operation include connection and setting procedures, switching on the device, and checking voltage and current outputs.
Load Connection
Guidelines for connecting loads include information on load wires, maximum allowable current, connectors, and the effects of noise and impedance. The manual also covers local and remote sensing for accurate measurements.
Operation
The operation section details menu navigation, voltage/current settings, sequence testing, and system parameter configurations. It includes instructions for setting IP addresses, baud rates, and language preferences.
Remote Operation
Details on using the RS232 interface and LAN port for remote control and connecting the device to a computer.
Maintenance and Self-Inspection
Regular maintenance procedures and fault self-inspection guidelines are provided to ensure the device's longevity and proper functioning.
Main Technical Data
This section includes the technical specifications of the N39200 series, such as voltage, current, and power ratings for different models.
Appendix
The appendix includes descriptions of protection and error alarms, communication interface details, a recommended wire gauge selection table, and troubleshooting tips.
Front Panel Overview
The front panel includes a screen and several buttons for device control, such as V I Set, Menu, CH, SEQ, PROT - CLR, On/Off, ESC, and Lock. A virtual keyboard is available for numeric input.
Rear Panel Overview
The rear panel includes channel interfaces, a four-wire interface, LAN port, RS232 interface, AC power socket, and grounding screw hole.
Power-on Test
Before operation, inspect the device for physical damage, ensure proper grounding, connect to the correct AC power, and perform a factory reset if necessary. Voltage and current output inspections are detailed to verify functionality.
Load Connection
Guidelines for selecting load wires include considering maximum allowable current, insulation level, and minimizing voltage drop. Connectors are provided for secure connections, and twisted-pair wires are recommended to reduce noise and impedance effects.
Local and Remote Sense
Local sense adjusts voltage at the output terminal, while remote sense compensates for voltage drops across wires, ensuring accurate voltage delivery to the load.
Operation
The device features several operational modes, including V/I mode for constant voltage and current output, and SEQ mode for simulating complex waveforms. Users can navigate the menu and set parameters using the screen or buttons.
Safety Precautions
Warnings are provided to prevent electric shock and ensure safe operation, emphasizing proper grounding and connection procedures.
SEQ Operation
SEQ mode allows users to program voltage and current outputs through a series of test steps. Users can enter SEQ mode via the front panel or screen interface. The sequence test starts by selecting a file number and pressing On/Off. The system automatically stops after completing all steps.
Channel Selection
Users can select channels using the front panel, screen touch, or rotary controls. This section details methods for selecting and setting parameters for each channel.
Parameter Setting
Parameters such as File No., Step No., Dwell time, and Cycle Times can be set through the screen or rotary controls. The system supports up to 10 sequence files with a maximum of 200 steps.
SEQ Edit
Users can edit sequence files to create complex waveforms. The document outlines methods to enter SEQ Edit mode and set parameters like CV Value, I-Limit, and Link Steps.
Channel Configuration
Users can set Over Voltage Protection (OVP), Over Current Protection (OCP), and Over Power Protection (OPP) for each channel. The system displays alarms when protection limits are exceeded.
CV/CC Priority
The power supply operates in either Constant Voltage (CV) or Constant Current (CC) mode based on load impedance. Users can prioritize CV or CC mode depending on application requirements.
System Configuration
Users can set IP addresses, baud rates, beep sounds, and display language. The RS232 interface does not support flow control.
Remote Operation
The N39200 supports RS232 and LAN communication interfaces. The document provides steps for setting up remote control via these interfaces, including setting baud rates and connecting multiple devices.
Remote Control Setup
To enable remote control of the N39200 series power supply, configure the application software on a PC. Set the communication mode to LAN and ensure the IP address matches that of the N39200. Once connected, the device will enter remote control mode, disabling local operations. To revert to local control, press the 'Lock' button.
Maintenance and Self-inspection
Regular maintenance involves cleaning the device with a dry or slightly damp cloth, ensuring the power is disconnected. For fault self-inspection, check power supply, device startup, fuse condition, connector integrity, system configuration, and device specifications. Calibration is recommended annually.
Technical Specifications
The N39200 series offers dual-channel programmable DC power supply with various models providing different voltage, current, and power specifications. Measurement accuracy is maintained under specific conditions, including a warm-up period of 30 minutes. The device supports LAN and RS232 interfaces and operates within specified environmental conditions.
Protection and Error Alarms
The device includes several protection mechanisms such as over voltage (OVP), over current (OCP), over power (OPP), over temperature (OTP), and low voltage protection (LVP). Error alarms indicate power supply faults.
Communication Interface
The N39200 series uses NGI's standard communication protocol with RS232 and LAN hardware interfaces. The RS232 interface supports multiple baud rates, while the LAN interface complies with IEEE 802.3 standards.
Wire Gauge Recommendations
Recommended wire gauges are provided based on temperature conditions and rated current, ensuring safe and efficient operation.
Troubleshooting
Common issues include screen malfunction, no output, improper voltage/current settings, unstable output voltage, and high output voltage ripple. Solutions involve checking connections, adjusting settings, and avoiding electromagnetic interference.
See more

Catalog excerpts

N39200 series User Manual 2 channel programmable dc power supply-1

Hunan Next Generation Instrumental T&C Tech. Co., Ltd. N39200 Series High-accuracy Dual-channel Programmable DC Power Supply User Manual © Copyright Hunan Next Generation Instrumental T&C Tech. Co., Ltd. Version: V20200731 N39200 Series High-accuracy Dual-channel Programmable DC Power Supply

 Open the catalog to page 1
N39200 series User Manual 2 channel programmable dc power supply-2

Hunan Next Generation Instrumental T&C Tech. Co., Ltd. N39200 Series High-accuracy Dual-channel Programmable DC Power Supply

 Open the catalog to page 2
N39200 series User Manual 2 channel programmable dc power supply-3

Hunan Next Generation Instrumental T&C Tech. Co., Ltd. N39200 Series High-accuracy Dual-channel Programmable DC Power Supply

 Open the catalog to page 3
N39200 series User Manual 2 channel programmable dc power supply-4

Hunan Next Generation Instrumental T&C Tech. Co., Ltd. 1 Preface Dear Customers, First of all, we greatly appreciate your choice of N39200 series DC power supply (N39200 for short). We are also honored to introduce our company, Hunan Next Generation Instrumental T&C Tech. Co., Ltd. ( NGI for short). About Company NGI is a professional manufacturer of intelligent equipment and test & control instruments, mainly engaged in design, production, sales, installations and maintenance of instruments and meters, electronic products, mechanical equipment, automatic test systems, computer software, automatic...

 Open the catalog to page 4
N39200 series User Manual 2 channel programmable dc power supply-5

Hunan Next Generation Instrumental T&C Tech. Co., Ltd. 2 Safety Instructions In the operation and maintenance of the instrument, please strictly comply with the following safety instructions. Any performance regardless of attentions or specific warnings in other chapters of the manual may impair the protective functions provided by the instrument. NGI shall not be liable for the results caused by the neglect of those instructions. 2.1 Safety Notes > Confirm the AC input voltage before supplying power. > Reliable grounding: Before operation, the instrument must be reliably grounded to avoid the...

 Open the catalog to page 5
N39200 series User Manual 2 channel programmable dc power supply-6

Hunan Next Generation Instrumental T&C Tech. Co., Ltd. 3 Product 3.1 Brief Introduction N39200 series is a high-accuracy & dual-channel programmable DC power supply, available for benchtop use. N39200 standalone supports 2 channels output, with each channel isolated. Both local operation on front panel and remote control on a computer are supported. N39200 can be widely used in lab test, system integration test, production aging line, etc. 3.1.1 Features ■ Automatic switch between CV and CC mode ■ High definition touch screen ■ Remote sense for accurate measurement ■ Single device with 2 channels,...

 Open the catalog to page 6
N39200 series User Manual 2 channel programmable dc power supply-7

Hunan Next Generation Instrumental T&C Tech. Co., Ltd. Front Panel Dimension(mm) Rear Panel Dimension(mm) N39200 Series High-accuracy Dual-channel Programmable DC Power Supply

 Open the catalog to page 7
N39200 series User Manual 2 channel programmable dc power supply-8

Figure 3 Side Dimension(mm) 3.4 Package Contents and Accessories After receiving N39200, please check the instrument according to the following steps: 1. Check whether the instrument is damaged during transportation. If any severe damage to the package, please contact our authorized distributor or NGI. 3. Make sure the the following accessories are attached. NGI l NGI N39200 Series High-accuracy Dual-channel Programmable DC Power Supply

 Open the catalog to page 8
N39200 series User Manual 2 channel programmable dc power supply-9

__ . -Hunan Next Generation Instrumental T&C Tech. Co., Ltd. 4 Panel Introduction 4.1 Front Panel Introduction Figure 5 Front Panel NGI l NGI N39200 Series High-accuracy Dual-channel Programmable DC Power Supply

 Open the catalog to page 9
N39200 series User Manual 2 channel programmable dc power supply-10

Hunan Next Generation Instrumental T&C Tech. Co., Ltd. 4.1.2 Button N39200 front panel mainly includes a screen and buttons. Users can control the device via buttons. To enter the main menu Channel switch for V/I, SEQ, CH Config,etc. To power on/off the output To exit from setting or the present page To lock/unlock Compound button 1. To shift or select the desired item in menu 2. To control the cursor scrolling when setting parameter By rotating: to select the desired item, adjust the parameter By pressing: to enter the edit interface, confirm the input N39200 Series High-accuracy Dual-channel...

 Open the catalog to page 10
N39200 series User Manual 2 channel programmable dc power supply-11

Hunan Next Generation Instrumental T&C Tech. Co., Ltd. 4.1.3 Virtual Keyboard N93200 is equipped with a virtual keypad on the screen for numeric input. Virtual Keypad 4.2 Rear Panel Introduction Rear Panel Name Channel interface Four-wire interface LAN port RS232 interface N39200 Series High-accuracy Dual-channel Programmable DC Power Supply

 Open the catalog to page 11
N39200 series User Manual 2 channel programmable dc power supply-12

Hunan Next Generation Instrumental T&C Tech. Co., Ltd. 4.2.1 Channel Interface Channel interface is used to connect the DUT. Please select the appropriate output wire according to the specific N39200 model. Do not use thin wires to avoid overheating, which may cause danger. Figure 9 Four-wire Interface LAN Figure 10 LAN Port LAN port is used for remote control, by connecting N39200 with PC via an Ethernet cable. NGI l NGI N39200 Series High-accuracy Dual-channel Programmable DC Power Supply

 Open the catalog to page 12
N39200 series User Manual 2 channel programmable dc power supply-13

Hunan Next Generation Instrumental T&C Tech. Co., Ltd. 4.2.4 RS232 Interface RS232 interface is used for remote control. RS232 cable is supplied as standard accessory. 4.2.5 AC Power Socket Please make sure the AC input voltage before supplying power. Please ensure that the AC input voltage supplied to N39200 should not be too low under high load conditions. The chassis of N39200 is insulated from the inner live conductor. However, after long-term use or by accident, the insulating part may be damaged, which causes the chassis to become charged. Grounding can effectively prevent electric shock....

 Open the catalog to page 13
N39200 series User Manual 2 channel programmable dc power supply-14

5 Power-on Test Proper inspection should be done before operating on N39200 to ensure N39200 can be used normally. Please follow the below steps in below table. Warning: If N39200 chassis and upper cover are not safely grounded, there is a danger of electric shock. 5.1.2 Switch-on Please press the power switch on the front panel. If N39200 can not be switched on properly, please check if the power cord is well connected and AC power supply is available. Warning: Even if the power switch is under off state, some components inside N39200 may still carry a high voltage. To avoid electric shock,...

 Open the catalog to page 14
N39200 series User Manual 2 channel programmable dc power supply-15

Hunan Next Generation Instrumental T&C Tech. Co., Ltd. 5.2 Output Inspection The output inspection can ensure that N39200 can reach its rated output and can perform the operations on the front panel properly. 5.2.1 Voltage Output Inspection Please follow the below steps to verify the basic voltage functions without a load. 1. Press the power switch on N39200. 2. Set voltage to 1V. O n /O ff 3. Press on the front panel to enable output. 4. Check if the displayed voltage is close to 1V. 5. Make sure the voltage can be adjusted from 0V to maximum voltage within the range. 5.2.2 Current Output Inspection...

 Open the catalog to page 15

All NGI Tech catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.