1. Catalogs
  2. NGI Tech
  3. N2600 series User Manual multi function source measure unit

N2600 series User Manual multi function source measure unit

N2600 series User Manual multi function source measure unit
1 / 98 PagesView full catalog

N2600 series User Manual multi function source measure unit

Product catalog summary
Preface
This manual is for the N2600 series Source Meter by Hunan Next Generation Instrumental T&C Tech. Co., Ltd. It covers installation, operation, and specifications, highlighting the company's expertise in intelligent equipment and test & control instruments.
Safety Instructions
  • Safety Notes: Designed for trained personnel aware of shock hazards. Ensure proper grounding and inspect cables before use.
  • Safety Symbols: Symbols indicate important safety information, such as electric shock and high temperature warnings.
  • Operating Environment: Suitable for indoor use with specific temperature, humidity, and altitude requirements.
Product Overview
The N2600 series is a high-precision source meter integrating voltage source, current source, and I/V/R measurement capabilities. It supports a wide measurement range and high accuracy, suitable for industries like communication, semiconductor, and automotive.
Main Features
  • 5-in-1 functionality (voltage source, current source, I/V/R measurement)
  • Wide measurement range and high accuracy
  • Supports pulse mode with a minimum pulse width of 150μs
  • Maximum sampling rate of 100ksps
  • Source and sink (4-quadrant) operation
  • 2/4/6-wire resistance measurement
  • Free PC application software with function calculator
  • SEQ test function and I-V characteristic analysis
  • Supports SCPI protocol and various sweep modes
  • Equipped with LAN port, RS232 interface, and front USB port
Design and Interface
The N2600 series features a user-friendly interface with a 4.3-inch LCD screen. The front panel includes a USB port, power switch, function buttons, and input/output ports. The rear panel provides additional connectivity options including LAN and RS232 interfaces.
Communication and Control
The device supports communication through RS232 and LAN ports, allowing remote control and integration with other instruments. The trigger port facilitates synchronized operations.
Operation Modes
  • CC Mode (Constant Current): Maintains a constant current output, allowing simultaneous measurement of voltage, current, resistance, and power.
  • CV Mode (Constant Voltage): Maintains a constant voltage output, with similar measurement capabilities as CC mode.
  • Resistance Measurement: Offers both automatic and manual measurement options, using the formula R=V/I for calculations.
Safety and Precautions
Users should disable outputs before connecting or disconnecting devices to prevent electric shocks. Proper configuration of test connections is essential.
Specifications and Measurement Ranges
The document outlines default test current settings and measurement resolutions for various resistance ranges, from 2Ω to 20MΩ.
Operation Sequence
Describes steps for resistance measurement using automatic and manual methods, and three connection methods: two-wire, four-wire, and six-wire connections.
Remote Control Programming
Includes SCPI instructions for programming the N2600 in resistance measurement mode, detailing commands for setting up automatic measurement and enabling output.
Sweep Operations
The N2600 supports linear, logarithmic, user-defined, and source memory sweeps, with specific configurations and parameters.
Trigger Function
Describes manual and remote trigger operations, including front panel triggers and trigger port links.
Function Performance (FCTN)
Includes mathematical operations like power calculation, offset-compensated ohms, and voltage coefficient.
Limit Test
Types include compliance, course, and fine restrictions with grading and sorting modes. Digital I/O ports connect source meter to processor for pass/fail signals.
Buffer and Data Storage
The system can store up to 2500 source measurement readings, with separate data read buffers for front panel and remote operations.
Signal Generation
Instructions for generating square and pulse waveforms, with specific configurations for frequency, duty cycle, and pulse width.
Key Parameters and Limitations
Important parameters include maximum duty cycle, pulse width, and overvoltage protection values, with guidelines for consistent pulse cycles.
See more

Catalog excerpts

N2600 series User Manual multi function source measure unit-1

ELECTRONIC SOLUTION PROVIDER FOR INTELLIGENT MANUFACTURING User Manual N2600 Series High Precision Source Meter(SMU) Hunan Next Generation Instrumental T&C Tech. Co., Ltd.

 Open the catalog to page 1
N2600 series User Manual multi function source measure unit-2

ELECTRONIC SOLUTION PROVIDER FOR INTELLIGENT MANUFACTURING Copyright Statement Hunan Next Generation Instrumental T&C Tech. Co., Ltd. (NGI for short) Without the prior permission and written consent of NGI, no content in this manual may be reproduced in any form (including electronic storage and retrieval or translation into a foreign language). NGI shall not be liable for errors or for incidental or consequential damages in connection with the provision, use or application of this manual and any information contained herein. The information provided in this manual is subject to change without...

 Open the catalog to page 2
N2600 series User Manual multi function source measure unit-3

ELECTRONIC SOLUTION PROVIDER FOR INTELLIGENT MANUFACTURING

 Open the catalog to page 3
N2600 series User Manual multi function source measure unit-5

ELECTRONIC SOLUTION PROVIDER FOR INTELLIGENT MANUFACTURING 1 Preface Dear Customers, First of all, we greatly appreciate your choice of N2600 series Source Meter (N2600 for short). We are also honored to introduce our company, Hunan Next Generation Instrumental T&C Tech. Co., Ltd.( NGI for short). About Company NGI is a professional manufacturer of intelligent equipment and test & control instruments, committed to developing, manufacturing battery simulators, power supplies, electronic loads, and many more instruments. The products can be widely used in the industries of battery, power supply,...

 Open the catalog to page 5
N2600 series User Manual multi function source measure unit-6

ELECTRONIC SOLUTION PROVIDER FOR INTELLIGENT MANUFACTURING 2 Safety Instructions 2.1 Safety Notes This instrument is intended for use by specific personnel. Such personnel need to be able to recognize shock hazards and be familiar with necessary safety precautions to avoid potential injury. Please read and follow all installation, operation, and maintenance information carefully before using this instrument. For complete product specifications, please refer to this manual. If the instrument is used in a manner not specified, the protective functions provided by the instrument could be impaired....

 Open the catalog to page 6
N2600 series User Manual multi function source measure unit-7

ELECTRONIC SOLUTION PROVIDER FOR INTELLIGENT MANUFACTURING cables, test leads, and jumpers for frayed or broken wires. Please be careful when there is a risk of electric shock during use. Hazardous voltages may be present in the cable connector jacks or test fixtures. There is a danger of electric shock when the voltage level exceeds 30Vrms, 42.4Vpeak or 60V DC, please take precautions. During the operation and use of this instrument, please strictly observe the following safety precautions. Failure to observe the following safety precautions or specific warnings indicated elsewhere in this manual...

 Open the catalog to page 7
N2600 series User Manual multi function source measure unit-8

ELECTRONIC SOLUTION PROVIDER FOR INTELLIGENT MANUFACTURING arnings Warnings indicates danger. It requires an attention before performing an operational step, and indicates conditions and actions that may endanger the life of the operator. Be sure to read the relevant information carefully before performing the specified procedure. Table 2-1 Safety Symbols 2.3 Operating Environment N2600 series SMU is suitable for indoor and low-condensation areas. Its general operating environment requirements are listed as below. Table 2-2 Operating Environment Requirements Operating Environment Requirement...

 Open the catalog to page 8
N2600 series User Manual multi function source measure unit-9

ELECTRONIC SOLUTION PROVIDER FOR INTELLIGENT MANUFACTURING 3 Product 3.1 Brief Introduction N2600 series is a digital source meter developed by NGI, which closely combines the functions of high-accuracy source and high-accuracy measurement. It integrates 5 functions (voltage source, current source, I/V/R measurement) in one instrument. The measurement range covers 200V to 1μV, 10A to 10pA, 200MΩ to 10μΩ. The maximum pulse output current can be up to 10A. The measurement resolution is 6½ digits. The basic accuracy can reach 100μV, 600pA, 300μΩ. N2600 series has built-in constant voltage source,...

 Open the catalog to page 9
N2600 series User Manual multi function source measure unit-10

ELECTRONIC SOLUTION PROVIDER FOR INTELLIGENT MANUFACTURING Supporting SCPI protocol Front USB port, supporting screenshot storage Supporting linear staircase sweep, logarithmic staircase sweep and custom sweep 4.3 inch LCD screen, simple operation interface, easy to use Remark【1】 :Only N2610-100-03 supports this function. 3.3 Overview 3.3.1 Appearance & Dimension 214.0 SourceMeter GUARD SENSE Figure 3-2 Rear Panel Dime

 Open the catalog to page 10
N2600 series User Manual multi function source measure unit-11

ELECTRONIC SOLUTION PROVIDER FOR INTELLIGENT MANUFACTURING 77.7 Figure 3-3 Side Dimension(mm) 3.3.2 Front Panel Introduction Figure 3-4 Front Panel Product Model No. and Basic Parameter Displaying related information Power Switch Turn on/off power supply of the device Function Button Specify the function listed at the bottom of the display

 Open the catalog to page 11
N2600 series User Manual multi function source measure unit-12

ELECTRONIC SOLUTION PROVIDER FOR INTELLIGENT MANUFACTURING

 Open the catalog to page 12
N2600 series User Manual multi function source measure unit-13

ELECTRONIC SOLUTION PROVIDER FOR INTELLIGENT MANUFACTURING Figure 3-5 Knob Table 3-3 Knob Function By rotating: to select the required item, adjust the parameter By pressing: to enter the edit interface, confirm the input 3.3.5 Front Panel Wiring Terminals s+ GUARD SENSE Figure 3-6 Front Panel Wiring Terminals Table 3-4 Identification Positive Sampling Terminal Negative Sampling Terminal Positive Input/Output Terminal Negative Input/Output Terminal Drive protection device GUARD SENSE Compensate the voltage drop in the output lead

 Open the catalog to page 13
N2600 series User Manual multi function source measure unit-14

ELECTRONIC SOLUTION PROVIDER FOR INTELLIGENT MANUFACTURING 3.3.6 Rear Panel Introduction Figure 3-7 Rear Panel Table 3-5 No. Output Port Digital I/O Input/Output Port Definition V+/V-、S+/S- Output port Ventilation and heat dissipation TRIGGER LINK External trigger link Power Input Switch Power Input Socket Connect AC220V/115V to supply power to the device Figure 3-8 Rear Panel Wiring Terminal

 Open the catalog to page 14
N2600 series User Manual multi function source measure unit-15

ELECTRONIC SOLUTION PROVIDER FOR INTELLIGENT MANUFACTURING

 Open the catalog to page 15
N2600 series User Manual multi function source measure unit-16

ELECTRONIC SOLUTION PROVIDER FOR INTELLIGENT MANUFACTURING 3.3.6.2 Trigger Port(Trigger) Input and output triggers receive and send through the rear panel trigger linker. The trigger port has four input and output trigger wires. In the test, select line #2 for output triggers, select line #1 for input triggers, and input/output line assignments can be changed in the Configure Trigger menu. Figure 3-10 shows the trigger ports. Rear Panel Pinout Figure 3-10 Trigger Port 3.3.6.3 Network Port(LAN) N2600 series is equipped with a LAN port for connecting the computer through a

 Open the catalog to page 16

All NGI Tech catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.