1. Catalogs
  2. Next Industries s.r.l
  3. NI2400/NI816/NI4866 DATALOGGER

NI2400/NI816/NI4866 DATALOGGER

NI2400/NI816/NI4866 DATALOGGER
1 / 28 PagesView full catalog

NI2400/NI816/NI4866 DATALOGGER

Product catalog summary
General Specifications:
The NI2400, NI816, and NI4866 are Ethernet data loggers with embedded web servers, supporting 8, 16, and 24 channels respectively. They feature relay outputs, digital and analog inputs, internal temperature sensors, and support for various measurement types including voltage, current, and thermocouples. The devices are expandable up to 384 channels using multiplexers and offer connectivity via Ethernet, RS485, RS232, and USB.
Physical Characteristics:
Each device weighs 980g and measures 231 x 138 x 117 mm. They are constructed from plastic and metal, with removable screw terminal connectors for wiring.
CPU and Memory:
Equipped with an ARM Cortex-M3 MCU, 1 MB Flash, and 1 Mbyte RAM, these devices include a 2 GB SD card for data storage and web pages. They feature a high precision RTC with battery backup.
Analog Inputs:
The NI2400 supports 24 differential analog inputs, while the NI816 supports 8-16 inputs. Inputs can be configured individually, and channel expansion is possible with multiplexers. The devices support various input types including current loops, transmitters, voltage, and Wheatstone bridges.
Measurement Specifications:
Measurement accuracy is 0.01% FS, with a temperature drift of less than 10 ppm/°C. The devices feature 24-bit differential ADCs and support a range of measurement rates.
Digital I/O:
Each device includes one relay output and two opto-isolated digital inputs, with a maximum input voltage of 24V.
Protections:
Features include electro-mechanical relays, circuit protection with gas discharge tubes, overvoltage, reverse polarity, and short circuit protection.
Interfaces:
Devices include a small backlight graphic LCD, Ethernet, RS232, and USB interfaces. RS485 connections support MODBUS RTU protocol.
Power Requirements:
Operating voltage ranges from 10 to 30 Vdc, with reverse polarity protection. Typical current drain varies based on operational mode.
Software & Firmware:
Includes an onboard web server, FTP client, email and SMS alerts, and data download capabilities in .csv format. Supports multiple languages including Italian, English, and French.
Environmental Conditions:
Operating temperature ranges from -30 to 70°C, with storage temperatures from -40 to 85°C. The devices are designed for use at altitudes up to 3000 meters.
System Power Requirements:
The system has a typical current drain of 62 mA when on, increasing to 142 mA with both display and ethernet connected. It is reverse polarity protected and supports sleep mode with a maximum current of 315 µA.
General Specifications:
The device supports 4-8 differential analog input channels and measures various parameters such as thermocouples, RTD, and mV/mA. It includes a GPRS modem, 6 digital outputs, and 6 digital inputs. The system offers Ethernet, RS485, RS232, and USB connections.
Digital I/O:
The system includes 6 relay outputs and 2 opto-isolated digital inputs, with additional digital inputs available for triggering acquisitions and alarms. It features protections such as overvoltage and reverse polarity protection.
Interfaces:
The data logger includes a small backlight graphic LCD and membrane keyboard for local management. It supports LAN Ethernet, RS232, USB, and RS485 connections.
See more

Catalog excerpts

NI2400/NI816/NI4866 DATALOGGER-1

8/16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server DATASHEET Rev. 08 del 08/10/2018 Redatto da R&D Approvato da MKT

 Open the catalog to page 1
NI2400/NI816/NI4866 DATALOGGER-2

GENERAL SPECIFICATIONS Internal Temperature Sensor Analog Expansion with Multiplexer Cloud Dashboard Management Option Analog Input Number Switchable Power Supply (Selectable by Software: 24V, 20V, 10V, 5V) DI/DO Expansion Memory 231 x 138 x 117 mm Plastic and Metal Screws clamp termination block up to 1,3mm2 (16AWG) Recommended every 1 year Wiring Calibration Operating Voltage 10 to 30V DC (reverse polarity protected) *Smart MUX: Allows to connect an NI100 to an NI10 and Multiplexers to read Vibrating Wire (with NTC) sensors. Up to 16 Multiplexers and 16 NI10, for a total of 384 sensors. **Depending...

 Open the catalog to page 2
NI2400/NI816/NI4866 DATALOGGER-3

GENERAL SPECIFICATIONS • Webserver on board • 24 Differential Analog Input Channels • Measures: Thermocouples, PT100 RTD, NTC Thermistor, mV, mA, mV/V • View Data in real Time or Store to 2 GB Internal Memory • GPRS Modem available • 0.01% FS Accuracy • Expandable up to 384 channels with multiplexers • Ethernet, RS485, RS232 and USB Connections • SMS and e-mail Alerts PHYSICAL CHARACTERISTICS Weight Removable screw terminal connectors

 Open the catalog to page 3
NI2400/NI816/NI4866 DATALOGGER-4

DETAILED SPECIFICATIONS ARM Cortex-M3 MCU with 1 MB Flash, 120 MHz CPU, ART Accelerator, Ethernet Mass storage 2 GB SD card for data (about 5 Mega data points) and Web pages Clock accuracy High precision RTC (real time clock with battery back-up) temperature compensated On-board sensors Temperature (accuracy ±1%), measured inside the datalogger ANALOG INPUTS Number of Inputs: 24 differential analog inputs, individually configured. Channel expansion provided by multiplexers. There are 8 terminal blocks (each terminal block can handle up to 3 sensors). NI2400 is designed to work with 2 to 6-wire...

 Open the catalog to page 4
NI2400/NI816/NI4866 DATALOGGER-5

DETAILED SPECIFICATIONS Maximum Speed Analog Measurements Measurement Rate Standard Speed Analog Initialization (±10V range) Instrument Warm-Up Depends on sensor configuration Times indicated are not valid for vibrating wire measures Init analog phase is made only once before measurement cycle 24-bit (22 true bit) differential analog-to-digital converters, 5SPS to 1000SPS, 0-24 average function, autocalibration and auto-range ADC: ANALOG INPUT TYPES Current Loop (2 Wires) 0 to 25 mA range; power supply: 24/10 Vdc, external 0 to 25 mA range; power supply: 24/10 Vdc, external ±10 mV, ±100 mV, ±1V,...

 Open the catalog to page 5
NI2400/NI816/NI4866 DATALOGGER-6

DETAILED SPECIFICATIONS THERMOCOUPLE (LOGGER @ 25°C AMBIENT TEMPERATURE) TC TYPE

 Open the catalog to page 6
NI2400/NI816/NI4866 DATALOGGER-7

DETAILED SPECIFICATIONS ANALOG MEASUREMENTS RTD Input Platinum (Pt100/200/500/1000) RTD: range -195 to 847°C (-319 to 1556°F); maximum error ±0,17% FS; power supply: 1.2 mA USB 2.0 full speed 5V, max 500mA, USB pendrive only Reading Resolution 1 µA at FS for 20 mA range; 1 µV at FS for ±10 mV range; 10 µV at FS for ±100 mV range; 100 µV at FS for ±1 V range; 1 mV at FS for ±10 V range; 0.1 °C for Pt100 RTD; 0.1 °C for NTC thermistor; 0.1 Hz for 6000 Hz range; 0.001 mV/V at FS for ±10 mV/V (Wheatstone bridge) 0.01% mV/mA FS (0.1% FS for Pt100 and NTC) - with Standard Measurement 0.13% mV/mA FS...

 Open the catalog to page 7
NI2400/NI816/NI4866 DATALOGGER-8

DETAILED SPECIFICATIONS DIGITAL I/O Digital Output One relay output (for alarm, etc.): volt-free closure (low voltage 30V, 2A) Digital Input: Two opto-isolated digital inputs Max Input Voltage: 24V (max current: 10mA) Min Input Voltage: 5V (max current: 2mA) Measurement Rate (MR): max frequency 1 kHz Accuracy: 0.1 Hz PROTECTIONS Electro-Mechanical Relays for Measuring Each Channel: Electrical Endurance: min 2 x 105 operations Mechanical Endurance: 100 x 106 operations. Circuit Protection (Gas Discharge Tubes): DC Breakdown Voltage (@100V/s): 75V Tolerance of DCBV: ± 20% Impulse Breakdown Voltage...

 Open the catalog to page 8
NI2400/NI816/NI4866 DATALOGGER-9

DETAILED SPECIFICATIONS Display & Keyboard Small backlight graphic LCD 128 x 64 dpi with membrane keyboard for the minimal local management without the PC. Keyboard for starting a data acquisition scan, sequential display of the last stored readings for each channel (sensor ID, converted unit reading, unit of measure), device status, data download and firmware/Web pages update by USB pen drive, safe mode (back-up/format/restore internal SD card). 9-pin, DE9: DCE port for optional GSM/GPRS modem connection Baud Rates: selectable from 9600 bps to 115.2 kbps Default Format: 8 data bits; 1 stop bits;...

 Open the catalog to page 9
NI2400/NI816/NI4866 DATALOGGER-10

DETAILED SPECIFICATIONS SOFTWARE & FIRMWARE • Web server on board (independent OS platform) • Acquisition Time Interval: selectable from 1 second up to 1 week (depends on the number of channels acquired) • FTP client to send data/alarms on an FTP server (SFTP not supported) • MAIL to send data/alarms to max 5 email address (SMTPS / SSL not supported) • SMS to send alarms to max 5 telephone numbers • Data download (readings, logs) in .csv file (compatible with Microsoft Excel) • Virtual channels management • Languages: Italian, English and French SYSTEM POWER REQUIREMENTS Voltage (External Power...

 Open the catalog to page 10
NI2400/NI816/NI4866 DATALOGGER-11

DETAILED SPECIFICATIONS ENVIROMENTAL CONDITIONS Operating Temperature Storage Temperature Relative Humidity Overvoltage Category Pollution Degree Sound Levels

 Open the catalog to page 11
NI2400/NI816/NI4866 DATALOGGER-12

GENERAL SPECIFICATIONS • Webserver on board • Differential Analog Input Channels • Measures: PT100 RTD, NTC Thermistor, mV, mA, mV/V • View Data in real Time or Store to 2 GB Internal Memory • GPRS Modem available • 0.01% FS Accuracy • Expandable up to 384 channels with multiplexers • Ethernet, RS485, RS232 and USB Connections • SMS and e-mail Alerts PHYSICAL CHARACTERISTICS Weight Removable screw terminal connectors

 Open the catalog to page 12
NI2400/NI816/NI4866 DATALOGGER-13

DETAILED SPECIFICATIONS ARM Cortex-M3 MCU with 1 MB Flash, 120 MHz CPU, ART Accelerator, Ethernet Mass storage 2 GB SD card for data (about 5 Mega data points) and Web pages Clock accuracy High precision RTC (real time clock with battery back-up) temperature compensated On-board sensors Temperature (accuracy ±1%), measured inside the datalogger ANALOG INPUTS Number of Inputs: 8-16 differential analog inputs, individually configured. Channel expansion provided by multiplexers. There are 8 terminal blocks (each terminal block can handle up to 2 sensors). NI816 is designed to work with 2 to 6-wire...

 Open the catalog to page 13

All Next Industries s.r.l catalogs and technical brochures

  1. NI74_DS

    3  Pages

  2. NI400_DS

    8  Pages

  3. NI100_DS

    4  Pages

  4. NI20X_DS

    3  Pages

  5. NI71N_DS

    3  Pages

  6. NIG80X_DS

    4  Pages

  7. NI10_DS

    23  Pages

  8. NI2400_DS

    12  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.